Blume Mechanical ServiceBlumeMechanical Service
Outdoor condenser unit, close-up

HVAC, explained

Thermostat setpoints for a commercial building on emergency power

Set cooling limits by zone before an outage based on what your facility team confirms can run on standby power, with higher cooling setpoints an option studied in commercial building simulations (DOE). During utility demand response events, The RMR Group may adjust thermostat settings slightly and leaves out tenant spaces where temperatures need to stay steady (Better Buildings partner page, RMR Group).

Tampa Electric counted nearly 600,000 outages after Hurricane Milton (Tampa Electric). For a Tampa Bay facility, plan the thermostat change by zone. Decide in advance where you can accept warmer conditions, where people would need to move if the building gets too hot, and who has authority to change the settings.

Start with the zones that can run warmer

DOE reported on a simulation of 34 control measures in 14 commercial building types across 16 U.S. climate zones, estimating how the controls could affect annual energy use and peak demand (DOE). One of the measures studied was changing temperature targets, including raising the cooling setpoint (DOE). DOE also modeled scheduling heating and cooling for the hours when occupants were most likely to be present (DOE). For an outage plan, put the occupied areas and their approved thermostat settings in front of the person running the building. Make the choice by space, so a setting for an ordinary office does not become the default for a temperature-sensitive operation.

Plan the adjustment before the outage

During utility demand response events, The RMR Group may make small changes to building thermostat settings and excludes tenant areas that are sensitive to temperature swings (Better Buildings partner page, RMR Group). In deciding whether a building can participate, the program considers whether it can reduce energy use while preserving comfort and whether tenants are willing to take part (Better Buildings partner page, RMR Group). The program alerts tenants ahead of scheduled events so they know how property staff will reduce demand (Better Buildings partner page, RMR Group). Adapt that approach to generator operation by agreeing in advance on who can change a setpoint, which rooms are excluded, and how occupants will hear about the change.

Know when to move people

Heat can make existing health problems worse and can cause heat-related illness (NWS). Infants, young children, older adults, pregnant women and people with chronic illnesses are among those more vulnerable to heat (NWS). The National Weather Service urges people to check on friends and family in those groups, especially if they lack AC (NWS). If an outage brings extreme heat, move to a powered community location and check with local officials for cooling locations that are open (Ready.gov). Include a destination and a way to notify occupants in your outage plan.

Keep moisture on the checklist

In its home moisture guidance, EPA advises keeping indoor relative humidity under 60 percent if possible, with 30 to 50 percent as the preferred range (EPA). Condensation on surfaces can be a clue that humidity is high (EPA). Relative humidity can be measured with a humidity meter (EPA). EPA recommends air conditioning or dehumidification when needed to bring humidity down (EPA). When planning a warmer cooling setpoint, give the facilities team a separate place to record humidity and visible condensation along with the room temperature.

Verify refrigeration before restocking

After a hurricane or flood, FDA tells restaurants and grocers to verify that refrigerated cases and walk-ins can consistently hold food at 41 degrees Fahrenheit or colder before stocking them, and to verify that freezer cases and walk-ins can keep food frozen (FDA). FDA also calls for checking that food preparation equipment operates correctly and is calibrated before returning it to use (FDA). When deliveries resume, FDA recommends having someone check package condition and confirm that incoming food meets temperature requirements (FDA). FDA recommends receiving foods that require temperature control either frozen or, for refrigerated storage, below 41 degrees Fahrenheit (FDA).

Keep portable generators outdoors

Never operate a portable generator inside a building or garage, where deadly carbon monoxide can accumulate (Tampa Electric). Portable generators should always run outdoors, at least 20 feet from doors, windows or attached garages (Ready.gov). Never connect a portable generator directly to home circuits, since power can flow back onto utility lines and endanger restoration workers (Tampa Electric). Leave generator installation, transfer equipment and wiring to a licensed contractor.

Frequently asked

Can we raise the setpoint if we have ceiling fans?

DOE's residential guidance says that with air conditioning running, a ceiling fan allows you to raise the thermostat setting by about 4 degrees Fahrenheit without reducing comfort (DOE). During an outage in extreme heat, Ready.gov recommends going to a community site that has electricity (Ready.gov).

Does every zone get the same thermostat change?

Give temperature-sensitive rooms their own limits. The RMR Group exempts tenant areas that need steady temperatures from its demand response measures (Better Buildings partner page, RMR Group).

What temperature should we check in a refrigerator or freezer?

In its household outage guidance, FDA recommends 40 degrees Fahrenheit or colder for the refrigerator and zero degrees Fahrenheit or colder for the freezer (FDA). Appliance thermometers show how cold each unit is during an outage and help with decisions about food safety (FDA).

Can we restock a walk-in as soon as it has power?

Confirm that it can hold temperature before loading it. After a hurricane or flood, restaurants and grocers should confirm before stocking their walk-ins that refrigerators can reliably stay at 41 degrees Fahrenheit or colder and freezers can reliably keep food frozen (FDA).

Do I need to call a pro for this?

Yes. The work belongs to a licensed contractor. Have the contractor handle any change to the standby circuits or transfer equipment, and have your facility team confirm with the contractor which HVAC equipment those circuits serve.

Related

Blume Mechanical Service, license CAC-1822618, serves Pinellas, Hillsborough and Pasco counties.

Sources: U.S. Department of Energy, Top 11 Things You Didn't Know About Saving Energy at Home: Summer Edition, https://www.energy.gov/articles/top-11-things-you-didnt-know-about-saving-energy-home-summer-edition · U.S. EPA, A Brief Guide to Mold, Moisture and Your Home, https://www.epa.gov/mold/brief-guide-mold-moisture-and-your-home · FDA, Food and Water Safety During Power Outages and Floods, https://www.fda.gov/food/buy-store-serve-safe-food/food-and-water-safety-during-power-outages-and-floods · FDA, Restaurants and Grocers Reopening After Hurricanes and Flooding, https://www.fda.gov/food/food-safety-during-emergencies/restaurants-and-grocers-reopening-after-hurricanes-and-flooding · NOAA/National Weather Service, Heat Safety Tips and Resources, https://www.weather.gov/safety/heat · Ready.gov (FEMA), Power Outages, https://www.ready.gov/power-outages · Tampa Electric, Achieving Power Restoration Milestones After Hurricane Milton, https://www.tampaelectric.com/mediacenter/2024/Tampa-Electric-Achieving-Power-Restoration-Milestones-After-Hurricane-Milton/ · DOE, Report Delves Into the Impacts of Commercial Building Controls on Energy Savings, https://www.energy.gov/cmei/buildings/articles/report-delves-impacts-commercial-building-controls-energy-savings · DOE Better Buildings, The RMR Group’s Demand Response Program, https://betterbuildingssolutioncenter.energy.gov/implementation-models/optimizing-building-electric-power-demand-rmr-groups-demand-response-program

Search Google for thermostat setpoint generator power commercial