HVAC, explained
Walk-in cooler and freezer during a power outage
Keep freezers and refrigerators closed during an outage and use a thermometer to monitor temperatures (Ready.gov). Throw out food held at 40°F or warmer for two hours or longer (Ready.gov). Before putting food back after a hurricane or flood, verify that the walk-in can reliably hold refrigerated food at 41°F or colder or keep frozen food frozen (FDA reopening guidance).
If an outage could contaminate food or prevent potentially hazardous food from staying at safe temperatures, the person in charge at a Florida public food service establishment must notify the Division of Hotels and Restaurants immediately (Florida Administrative Code). If the division orders an emergency closure, it will inspect no more than 24 hours after the closure, and the business can request an earlier visit (Florida DBPR). Florida DBPR says the business may reopen once an inspection shows every violation behind the closure has been corrected.
Keep the cold in and check temperatures
Keep refrigerator and freezer doors shut as much as possible while power is out so the units stay cold (FDA outage guidance). Set up appliance thermometers before an outage so you can check each unit when the power fails (FDA outage guidance). The FDA’s general outage guidance recommends keeping a freezer at 0°F or colder and a refrigerator at 40°F or colder (FDA outage guidance). Once electricity returns, check the temperature of the refrigerator or the food inside (FDA outage guidance). For refrigerated food, FDA says it should still be safe after an outage of 4 hours or less if you kept the doors closed (FDA outage guidance).
How long a closed refrigerator or freezer stays cold
FDA estimates about 4 hours of cold storage in a refrigerator that stays shut during the outage (FDA outage guidance). With the door closed, FDA estimates a full freezer will hold its temperature for about 48 hours and a half-full freezer for about 24 hours (FDA outage guidance). In its storm advice, USDA says food stays below 40°F in an unopened refrigerator for up to 4 hours (USDA Farm Service Agency). USDA estimates approximately 48 hours for a full freezer to hold a safe temperature and 24 hours for a half-full freezer if its doors stay closed (USDA Farm Service Agency). Ready.gov advises monitoring temperatures with a thermometer during an outage.
When to discard refrigerated food
FDA says to discard refrigerated perishables, including meat, milk and leftovers, after 4 hours or more at refrigerator temperatures above 40°F (FDA outage guidance). Ready.gov’s general outage advice calls for discarding food exposed to 40°F or warmer for 2 hours or longer, as well as food with an unusual smell, color or texture (Ready.gov). Discard perishables held at room temperature for at least 2 hours, or for 1 hour if the outdoor temperature exceeds 90°F (FDA outage guidance). Cooking food thoroughly may still leave a risk of illness if perishable food was inadequately refrigerated or frozen (FDA outage guidance).
Check frozen stock before deciding what to save
If you kept an appliance thermometer in the freezer, read it when power returns (FDA outage guidance). A reading no higher than 40°F on that thermometer means it is safe to refreeze the food (FDA outage guidance). If you had no appliance thermometer in the freezer, check each package on its own (FDA outage guidance). A normal smell or appearance cannot establish that food is safe (FDA outage guidance). FDA says a package can be refrozen or cooked if the food still has ice crystals or its temperature is 40°F or colder (FDA outage guidance). In a restaurant or grocery after a flood, discard refrigerated or frozen food that was immersed in floodwater (FDA reopening guidance).
Check the walk-in before restocking
Before reopening after a hurricane or flood, the person in charge should carry out a complete self-inspection to confirm normal operations can resume safely (FDA reopening guidance). Check that the refrigeration equipment works and is intact, and verify that it can keep foods that require time and temperature control for safety at 41°F or below (FDA reopening guidance). Check that equipment used to cool, cook or reheat food works and is correctly calibrated before using it (FDA reopening guidance). At receiving, have someone check incoming packages for damage and make sure they meet temperature requirements (FDA reopening guidance). Food requiring temperature control should arrive frozen or, for refrigerated storage, below 41°F (FDA reopening guidance).
Plan for backup power before the next outage
Tampa Electric calls for a licensed electrician to install a fixed standby generator with a double-throw transfer switch for use during an outage (Tampa Electric). A correctly installed switch separates the generator from the grid, preventing backfeed and protecting crews working on the line (Tampa Electric). To protect utility line workers, never connect a portable generator to household circuits, a meter box, a breaker panel or a fuse box (Tampa Electric). Ready.gov says generators and their fuel should always be used outdoors, with at least 20 feet of clearance from windows, doors and attached garages. Tampa Electric says never to operate a portable generator indoors, in a closed garage, near AC ducts or in another enclosed area. Tampa Electric warns that using a portable generator inside a home or other enclosed area can produce deadly carbon monoxide. Ready.gov says carbon monoxide can kill and has no color or odor. Keep the generator dry and shielded from rain and flooding (Ready.gov). Touching a wet generator or anything connected to it can shock you (Ready.gov).
Frequently asked
Do I need to call a pro for this?
Yes. The work belongs to a licensed contractor. Use a licensed electrician for a standby generator installation, and call an electrician for generator repairs (Tampa Electric).
Can a restaurant reopen as soon as power returns?
Not automatically. FDA says restaurants and grocers that had to stop operating in an emergency, or were hit by a natural disaster, should wait for approval from the state or local regulator before reopening (FDA reopening guidance).
What if floodwater got into a refrigerated display case?
Remove contaminated food and its juices before cleaning the case (FDA reopening guidance). Refrigerated storage equipment should be washed thoroughly inside and out using a hot detergent solution, then rinsed to remove detergent and residue (FDA reopening guidance). Pay particular attention to handles, gaskets and drains, and sanitize all cleaned surfaces (FDA reopening guidance).
What can I have ready before a storm?
FDA recommends having coolers available to keep refrigerated food cold if power will be out longer than 4 hours (FDA outage guidance). Prepare ice and freeze gel packs ahead of time (FDA outage guidance). USDA also recommends freezing water in small containers or plastic storage bags that can fit around food in the refrigerator or freezer (USDA Farm Service Agency).
How can I handle limited staffing when we reopen?
If only a few trained employees are available to work, reduce the number of dishes on the menu (FDA reopening guidance).
Related
- Freezers and fridges on a generator: food safety
- Planning HVAC on backup power for up to 90 days
- First 72 hours of a power outage: HVAC and generator steps
- Generator carbon monoxide and backfeeding: safe placement and wiring
Call (727) 330-9131.
Sources: FDA, "Food and Water Safety During Power Outages and Floods", https://www.fda.gov/food/buy-store-serve-safe-food/food-and-water-safety-during-power-outages-and-floods · FDA, "Restaurants and Grocers Reopening After Hurricanes and Flooding", https://www.fda.gov/food/food-safety-during-emergencies/restaurants-and-grocers-reopening-after-hurricanes-and-flooding · Ready.gov (FEMA), "Power Outages", https://www.ready.gov/power-outages · Florida Administrative Code, Rule 61C-4.010, https://www.law.cornell.edu/regulations/florida/Fla-Admin-Code-Ann-R-61C-4-010 · Florida DBPR Division of Hotels and Restaurants, "Inspections", https://www2.myfloridalicense.com/hotels-restaurants/inspections/ · Tampa Electric, "Storm Center", https://www.tampaelectric.com/Storm · USDA Farm Service Agency, California flood preparedness announcement, https://www.fsa.usda.gov/news-events/news/03-09-2023/usda-recommends-food-safety-tips-additional-resources-potential