HVAC, explained
Freezers and fridges on a generator: food safety
Keep the refrigerator and freezer doors shut: an unopened refrigerator keeps food cold for about four hours, and a full freezer for about 48 hours (FDA). Discard refrigerated food that has been at 40°F or higher for two hours or more (Ready.gov (FEMA)). Never run a generator indoors, and never connect it to house wiring without a transfer switch installed by a licensed electrician.
Hurricanes and grid failures can leave Tampa Bay homes without power for a long time. Hurricane Ian left over 2.6 million Florida customers without power in September 2022, some for over two weeks (EIA). This guide covers how long food stays safe and when to throw it out. It also covers how to restart a compressor, and how to run a generator without putting carbon monoxide or backfeed into the house. Plan before the storm, because after a hurricane you may not have access to supplies for days or even weeks (Ready.gov (FEMA)).
How long food stays safe without power
An unopened refrigerator keeps food cold for about four hours (FDA). A full freezer keeps its temperature for about 48 hours, and a half-full freezer for about 24 hours, with the door closed (FDA). Ready.gov gives the same four-hour and 48-hour figures (Ready.gov (FEMA)). Those times assume the doors stay closed, so write down when the power failed and open the doors only when you must. If food has to move, pack it in coolers with ice and monitor temperatures with a thermometer (Ready.gov (FEMA)).
Temperatures and the discard rule
Keep the refrigerator at or below 40°F and the freezer at or below 0°F. Check both with an appliance thermometer (FDA). FDA says food in a freezer reading 40°F or below may be refrozen (FDA). FDA says to discard refrigerated perishable food that has been above 40°F for four hours or more (FDA). Ready.gov uses two hours (Ready.gov (FEMA)). Where the two differ, this guide uses the stricter figure: discard food that has been at 40°F or higher for two hours or more. At exactly 40°F, the two-hour rule governs. If the power is out for more than a day, discard medication that should be refrigerated unless its label says otherwise (Ready.gov (FEMA)).
How to check each appliance's load
Set the order with your electrician, based on each appliance's load. Find the running rating on the nameplate, and ask the manufacturer for any starting figure. Then compare the total with the generator's rating for your fuel. A 10 kW Generac Guardian is rated 10,000 W on propane and 9,000 W on natural gas, that manufacturer's published figure for that model (Generac). Briggs & Stratton defines motor starting power as the momentary surge heavy motors need, such as a 5-ton air conditioner (Briggs & Stratton). Choosing a standby generator means looking beyond running wattage (Briggs & Stratton).
Restart the compressor after power returns
Wait before switching anything back on. Tampa Electric advises waiting 5 to 10 minutes after power returns before turning appliances and electronics back on, to help avoid damage (Tampa Electric). Some mini-split makers add their own delay; Fujitsu says its Airstage units wait about 3 minutes (Fujitsu General (Airstage)). Other brands use different delays, so check your unit's manual or ask the manufacturer. If the unit hums without starting or the breaker trips again, stop and call a technician instead of retrying.
Carbon monoxide: where the generator goes
Set a portable generator outdoors, more than 20 feet from windows, doors and vents (CDC). These distances are for portable units; ask the manufacturer for a standby unit's placement. The CPSC says at least 20 feet for portable units (CPSC); this guide uses the larger CDC distance. Keep the exhaust pointed away from the home (FEMA). Never run a generator inside the home or a garage, even with doors and windows open (CDC). Opening doors or windows will not provide enough ventilation to stop carbon monoxide from building up (CPSC). Florida's emergency management office says never run a generator in enclosed spaces like garages or basements (Florida Division of Emergency Management). Install battery-operated or battery back-up CO alarms near every sleeping area (CDC), and on every level of the home (Ready.gov (FEMA)). Replace them following the manufacturer's instructions or every 5 years (CDC). Interconnected alarms work together: when one sounds, they all sound (CPSC).
Never backfeed the house
Do not plug a generator into a wall outlet or the main electrical panel (FEMA). Tampa Electric says not to connect portable generators to home circuits, a breaker panel, fuse box or meter box (Tampa Electric). Backfeeding can send power into utility lines, where line workers may assume the lines are dead (Generac Support). A transfer switch physically isolates the home from the grid so a running generator cannot backfeed it (Generac Support). Have a licensed electrician install transfer equipment. Blume can supply a generator; the electrical installation is referred to a licensed electrician.
Fuel: gas service, propane and gasoline storage
Natural gas service can be shut off during a storm. Peoples Gas said it may need to turn off some customers' service at the meter after a storm (Peoples Gas). Customers whose gas is off must call to have it restored (Peoples Gas). Florida's emergency management office recommends leaving gas service on, and says only the gas company or emergency personnel should turn the meter valve (Florida Division of Emergency Management). For gasoline, Honda says fuel can deteriorate in less than 30 days (Honda Engines). Honda advises buying no more than a three-month supply, and says a stabilizer does not restore stale fuel (Honda Engines). Before refueling a running portable unit, turn it off and let it cool at least 20 minutes (Florida Division of Emergency Management).
Extended outages and help from Blume
Ready.gov says to take an inventory of items that rely on electricity, and to have a plan for power-dependent medical devices (Ready.gov (FEMA)). For a refrigerator or freezer on generator power, ask the manufacturer or your electrician for a run cycle. Blume Mechanical Service works on HVAC and refrigeration equipment, is brand-agnostic, and was founded in 2009. License CAC-1822618. Blume serves Pinellas, Hillsborough and Pasco counties.
Frequently asked
Does a full freezer stay cold longer than a half-full one?
Yes. With the door closed, a full freezer keeps its temperature for about 48 hours and a half-full freezer for about 24 hours (FDA). Keep the freezer at or below 0°F (FDA).
How long can the refrigerator stay closed and keep food safe?
An unopened refrigerator keeps food cold for about four hours (FDA). Refrigerated food that has been at 40°F or higher for two hours or more should be discarded (Ready.gov (FEMA)). Keep the door shut, since the four-hour figure assumes it stays closed (FDA).
Can I plug the generator into a wall outlet to run the fridge?
No. FEMA says never plug a generator into a wall outlet or the main electrical panel (FEMA). Do not connect a generator to house wiring except through transfer equipment installed by a licensed electrician.
How long should I wait before turning the refrigerator back on?
Tampa Electric advises waiting 5 to 10 minutes before turning on appliances and electronics (Tampa Electric). Check your unit's manual for its delay.
Is freezer food still safe if the thermometer reads 40°F?
FDA says food in a freezer reading 40°F or below may be refrozen (FDA). If food has been at 40°F or higher for two hours or more, discard it (Ready.gov (FEMA)). At exactly 40°F, the two-hour rule governs.
Does Blume install generators?
Blume can supply a generator; the electrical installation is referred to a licensed electrician, and Blume does not install the electrical connection. Blume Mechanical Service works on HVAC and refrigeration equipment. Call 727-330-9131.
Related
- Thermostat settings on backup power: 78°F, humidity and mold
- Running an AC on a home generator: load management
- Generator fuel for a long outage: propane, gas, diesel
- Hurricane Season HVAC Prep in Florida
Blume Mechanical Service (license CAC-1822618) works on HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: FDA — Food and Water Safety During Power Outages and Floods (https://www.fda.gov/food/buy-store-serve-safe-food/food-and-water-safety-during-power-outages-and-floods) · Ready.gov (FEMA) — Power Outages (https://www.ready.gov/power-outages) · Ready.gov (FEMA) — Water (https://www.ready.gov/water) · Ready.gov (FEMA) — Hurricanes (https://www.ready.gov/hurricanes) · FEMA — Lost power due to the storm? (https://www.fema.gov/node/lost-power-due-storm) · Tampa Electric — Storm Center (https://www.tampaelectric.com/stormcenter) · Fujitsu General (Airstage) — AIRSTAGE MINI-SPLITS Troubleshooting (https://www.airstagehvac.com/us/support/faq/halcyon/troubleshooting.html) · Generac Support — Why you should never back-feed your electric panel with a generator (https://support.generac.com/s/article/why-you-should-never-back-feed-your-electric-panel-with-a-generator) · Generac Support — Do I still need to maintain my generator even if it's low use? (https://support.generac.com/s/article/Do-I-still-need-to-maintain-my-generator-even-if-it-s-low-use) · Generac — 10kW Guardian Series Home Generator | 7171 (https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-10kw-wifi-enabled-7171/) · Briggs & Stratton Energy Solutions — PowerProtect+ Standby Generators: A Buyer's Guide (https://energy.briggsandstratton.com/en-us/resources/article-categories/resource-articles/guide-to-generators) · CDC — Carbon Monoxide (CO) Poisoning Basics (https://www.cdc.gov/carbon-monoxide/about/index.html) · CPSC — CPSC Urges Caution When Using Portable Generators as Tropical Storm Ian Continues its Path of Destruction (https://www.cpsc.gov/Newsroom/News-Releases/2022/CPSC-Urges-Caution-When-Using-Portable-Generators-as-Tropical-Storm-Ian-Continues-its-Path-of-Destruction) · Florida Division of Emergency Management — Generator Safety (https://www.floridadisaster.org/planprepare/generator-safety/) · Florida Division of Emergency Management — Gas Utilities (https://www.floridadisaster.org/planprepare/home/gas-utilities/) · EC&M (Mike Holt) — NEC Requirements for Emergency and Standby Systems (https://www.ecmweb.com/national-electrical-code/code-basics/article/55285564/nec-requirements-for-emergency-and-standby-systems) · Peoples Gas — Peoples Gas is Prepared for Milton (https://www.peoplesgas.com/mediacenter/2024/peoples-gas-is-prepared-for-milton/) · Honda Engines — Fuel Recommendations (https://engines.honda.com/support-and-service/fuel-recommendations) · U.S. Energy Information Administration — U.S. electricity customers averaged five and one-half hours of power interruptions in 2022 (https://www.eia.gov/todayinenergy/detail.php?id=61303)
Search Google for freezer refrigerator generator power outage food safety