Blume Mechanical ServiceBlumeMechanical Service
Outdoor condenser unit, close-up

HVAC, explained

Thermostat settings on backup power: 78°F, humidity and mold

A generator burns more fuel as load rises (Generac, one model); how much a setpoint changes that is not published. Keep indoor humidity below 60 percent (EPA), use air conditioning or find a location that has it for people at risk (CDC), and use fans only while indoor air is below 90°F (CDC). Generator fuel figures are each manufacturer's published numbers for one model, not rules for any home.

Hurricane Milton caused nearly 600,000 outages on Tampa Electric's system in 2024 (Tampa Electric). When power is out for days, the thermostat is the control that decides how much cooling a generator must carry and how humid the house becomes. This page covers fuel, humidity, room choice, fans, heat illness, generator safety and restart checks.

How much fuel a generator burns on one model

A generator burns more fuel as it carries more load (Generac, one model); how much a setpoint changes that is not published. Generac's 10 kW Guardian, model 7171, burns 1.48 gallons per hour of propane at 100 percent load (Generac). It burns 0.97 gallons per hour at 50 percent (Generac). Actual burn varies with load, so use these as reference points.

The 78°F figure is a comparison for normal use. The Department of Energy says running at 78°F instead of 72°F can save between 6 and 18 percent on the cooling bill (DOE). That is a bill figure, not a generator fuel figure. We found no published figure that converts a setpoint change into generator run time, so measure it. Note the fuel gauge or tank level at the start of the first outage night and again the next morning.

Humidity and mold: what the numbers say

EPA recommends keeping indoor relative humidity below 60 percent, ideally between 30 and 50 percent (EPA). EPA also says to use air conditioners or dehumidifiers when needed (EPA). Check a dehumidifier's running watts on its nameplate before you plug it into a generator.

EPA's mold timing applies to wet materials. If materials get wet from a leak or spill, dry them within 24 to 48 hours (EPA). If wet materials are dried within that window, in most cases mold will not grow (EPA). We found no published time for how long a Florida house can sit above 60 percent humidity before mold forms. Track indoor humidity with a hygrometer, and ask a licensed HVAC technician how the system holds humidity in an outage.

Air conditioning for people at risk

CDC's general advice in a heat event is to use air conditioning or find a location that has it, by dialing 2-1-1 (CDC). Whether a generator can carry a whole-house setpoint depends on its rating and the system's starting load, so do not assume it can.

If a single-room ductless system is part of the plan, ask the installer for its start current. Trane says each start of an inverter mini-split outdoor unit uses more energy than regular running (Trane). Trane also says an inverter system runs longer at reduced capacity instead of cycling (Trane). Do not stop and restart the unit to test it. Fujitsu says its Airstage units will not run for about 3 minutes after being stopped and immediately started (Fujitsu).

Fans help people, not rooms, and they have a limit

The Department of Energy says a ceiling fan lets you raise the thermostat about 4°F with no loss of comfort, because fans cool people rather than rooms (DOE). That is an energy-saving comparison for ordinary days.

CDC sets a health limit. Use fans only if indoor temperatures are below 90°F, because above 90°F a fan can increase body temperature (CDC). CDC also says not to rely on a fan as the main cooling source when it is very hot outside (CDC). During an outage, follow the CDC limit. The energy-saving comparison does not apply once indoor air is above 90°F.

Heat illness: who needs cooling first

CDC says power failures in hot weather can be deadly, and asks people to check on neighbors, relatives and others at risk (CDC). People over 65 and young children may need additional action on hot days (CDC). Older adults should stay in air-conditioned buildings as much as possible (CDC). The National Weather Service asks people to check in on relatives and friends in these groups, especially those without air conditioning (NWS).

Warning symptoms of overheating include muscle cramping, unusually heavy sweating, shortness of breath, dizziness, headaches, weakness and nausea (CDC). CDC says to know when to seek medical care (CDC). Ready.gov advises going to a community location with power if heat is extreme (Ready.gov). Take an inventory of the items that rely on electricity, including medical devices, before the outage starts (Ready.gov).

Generator safety while the thermostat runs

Run a generator only outdoors. CDC says to keep it more than 20 feet away from any windows, doors and vents (CDC). These distances are for portable units; ask the manufacturer for a standby unit's placement. Ready.gov says at least 20 feet from windows, doors and attached garages (Ready.gov). Where the two wordings differ, use the CDC's more-than-20-feet distance. Never run a generator inside a home or garage, even with doors and windows open (CDC). Opening doors or windows will not provide enough ventilation to prevent lethal carbon monoxide buildup (CPSC). Florida's Division of Emergency Management says never run a generator in enclosed spaces such as garages or basements (Florida DEM).

Install battery-operated or battery back-up CO detectors near every sleeping area (CDC). Ready.gov advises working CO detectors on every level of the home (Ready.gov).

Never connect a generator to a wall outlet or the main electrical panel (FEMA). Generac says backfeeding can electrocute utility workers who assume lines are dead (Generac), and that backfeeding is illegal in many places and violates the National Electrical Code (Generac). A transfer switch isolates the home from the grid so a running generator cannot backfeed it (Generac). Blume can supply a generator; the electrical installation is referred to a licensed electrician.

Fuel storage: gasoline can deteriorate in less than 30 days, and Honda advises buying no more than a 3-month supply (Honda). A stabilizer does not restore stale fuel (Honda). Before refueling a running portable unit, turn it off and let it cool for at least 20 minutes (Florida DEM). Florida's Division of Emergency Management recommends leaving gas service on, and only the gas company or emergency personnel should turn the meter valve (Florida DEM).

When power returns: what to check on the system

Tampa Electric says to wait 5 to 10 minutes after power returns before turning on appliances and electronics, to help avoid damage (Tampa Electric). Start with the thermostat: confirm it has power and is calling for cooling. Then check the breaker panel. Fujitsu says its Airstage mini-split compressor waits about 3 minutes after an immediate restart; other brands may differ (Fujitsu). For a central system, check the unit's nameplate and ask the manufacturer or a licensed technician about its restart delay.

If the generator is new, Generac says to stop at 25 hours during an extended outage to complete break-in tasks (Generac). Generac also says to follow continuous-use checks and daily oil inspections (Generac). The oil-change interval is in the owner's manual for your model. If gas service was shut off at the meter, the utility says the customer must call to have it restored (Peoples Gas). Test CO detectors when power returns and replace them following the manufacturer's instructions or every 5 years (CDC).

Frequently asked

What thermostat setting should I use on a generator?

No single setting fits every home on backup power. The Department of Energy's 78°F and 72°F comparison is a normal-use bill figure (DOE). For heat safety, CDC's fan limit is 90°F indoors (CDC). Set a temperature that keeps the people at risk safe, then check the generator's fuel level against it.

Does a fan keep me cool during a power outage?

Only while indoor temperatures are below 90°F (CDC). Above 90°F a fan can increase body temperature, and CDC says not to rely on a fan as the main cooling source in very hot weather (CDC).

How humid is too humid after an outage?

EPA recommends keeping indoor humidity below 60 percent, ideally between 30 and 50 percent (EPA). If materials get wet from a leak or spill, dry them within 24 to 48 hours (EPA).

Can I run my generator in the garage with the door open?

No. CDC says never use a generator inside a home or garage, even if doors and windows are open (CDC).

Can I plug my generator into a wall outlet to run the air conditioner?

No. FEMA says never plug a generator into a wall outlet or main electrical panel (FEMA). Generac says a transfer switch isolates the home from the grid so a running generator cannot backfeed it (Generac). The electrical installation is referred to a licensed electrician.

Who should I check on first?

The National Weather Service asks people to check on relatives and friends who are at risk, especially those without air conditioning (NWS). CDC names people over 65 and young children as needing extra action on hot days (CDC).

Related

Blume Mechanical Service (license CAC-1822618) works on HVAC and refrigeration equipment across Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.

Sources: Generac — 10kW Guardian Series Home Generator | 7171 (https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-10kw-wifi-enabled-7171/) · U.S. Department of Energy — Top 11 Things You Didn't Know About Saving Energy at Home: Summer Edition (https://www.energy.gov/articles/top-11-things-you-didnt-know-about-saving-energy-home-summer-edition) · U.S. Environmental Protection Agency — A Brief Guide to Mold, Moisture and Your Home (https://www.epa.gov/mold/brief-guide-mold-moisture-and-your-home) · Tampa Electric — Storm Center (https://www.tampaelectric.com/stormcenter) · Tampa Electric — Tampa Electric Achieving Power Restoration Milestones After Hurricane Milton (https://www.tampaelectric.com/mediacenter/2024/Tampa-Electric-Achieving-Power-Restoration-Milestones-After-Hurricane-Milton/) · Trane — Do Mini-Splits Turn Off When the Temperature Is Reached (https://www.trane.com/residential/en/resources/troubleshooting/ductless-systems/do-mini-splits-turn-off-when-temperature-is-reached/) · Fujitsu General (Airstage) — AIRSTAGE MINI-SPLITS Troubleshooting (https://www.airstagehvac.com/us/support/faq/halcyon/troubleshooting.html) · CDC — About Heat and Your Health (https://www.cdc.gov/heat-health/about/index.html) · CDC — Heat and Older Adults (Aged 65+) (https://www.cdc.gov/heat-health/risk-factors/heat-and-older-adults-aged-65.html) · CDC — Power Failures in Hot Weather (https://www.cdc.gov/natural-disasters/psa-toolkit/power-failures-in-hot-weather.html) · CDC — Carbon Monoxide (CO) Poisoning Basics (https://www.cdc.gov/carbon-monoxide/about/index.html) · National Weather Service — Heat Safety Tips and Resources (https://www.weather.gov/safety/heat) · U.S. Consumer Product Safety Commission — CPSC Urges Caution When Using Portable Generators as Tropical Storm Ian Continues its Path of Destruction (https://www.cpsc.gov/Newsroom/News-Releases/2022/CPSC-Urges-Caution-When-Using-Portable-Generators-as-Tropical-Storm-Ian-Continues-its-Path-of-Destruction) · Ready.gov (FEMA) — Power Outages (https://www.ready.gov/power-outages) · FEMA — Lost power due to the storm? (https://www.fema.gov/node/lost-power-due-storm) · Generac Support — Why you should never back-feed your electric panel with a generator (https://support.generac.com/s/article/why-you-should-never-back-feed-your-electric-panel-with-a-generator) · Generac Support — Do I still need to maintain my generator even if it's low use? (https://support.generac.com/s/article/Do-I-still-need-to-maintain-my-generator-even-if-it-s-low-use) · Florida Division of Emergency Management — Generator Safety | Florida Disaster (https://www.floridadisaster.org/planprepare/generator-safety/) · Florida Division of Emergency Management — Gas Utilities | Florida Disaster (https://www.floridadisaster.org/planprepare/home/gas-utilities/) · Peoples Gas — Peoples Gas is Prepared for Milton (https://www.peoplesgas.com/mediacenter/2024/peoples-gas-is-prepared-for-milton/) · Honda Engines — Fuel Recommendations (https://engines.honda.com/support-and-service/fuel-recommendations)

Search Google for thermostat settings during power outage florida