What a 14 to 18 kilowatt home standby generator can run on each fuel

For a 1,550 sq ft home, Generac says a 14 to 18 kW unit has enough capacity for central air or a well pump, and a 14 or 18 kW unit paired with a Load Manager or soft-start kit can absorb a 3-ton air conditioner's startup surge (Generac). Kohler rates its single-phase 14RCA at 14 kW on propane and 12 kW on natural gas (Kohler). Generac rates its Guardian 7226 for continuous output of up to 18 kW on propane or 17 kW on natural gas (Generac). Generac's Guardian 7223 has a maximum continuous output of 14 kW on either fuel (Generac).

Hurricane Milton caused close to 600,000 outages across Tampa Electric's system (Tampa Electric). Generac's planning steps are to list the essential appliances and then check the starting and running watts of anything with a motor (Generac).

What fits on backup power

Generac puts refrigeration, LED lights, phone chargers and the equipment that provides home internet among the essentials for an outage (Generac). A microwave, a toaster oven and a small window air conditioner are examples of additional loads that Generac groups between those essentials and the largest draws (Generac). Central air, an electric clothes dryer, an electric range and EV charging are among the high-demand loads Generac identifies for standby sizing (Generac). Generac's working formula for the kW needed is the sum of all running wattages plus the highest single starting wattage burst (Generac).

Two homes with the same floor area can have quite different electrical loads (Generac). Generac gives the example of a house with gas heat and one air conditioner versus a house with a well pump and an electric heat pump (Generac). During a site survey, an authorized Generac seller can measure the loads on the home's electrical panel and recommend a generator and Load Manager setup for that home (Generac).

Starting central air

Running wattage describes the power a piece of equipment draws once it is operating (Generac). Starting wattage is the short burst it may need to get a motor moving (Generac). Generac says a typical 3-ton central air conditioner draws about 3.5 to 5 kW while running and can need as much as 15 to 18 kW when the compressor starts (Generac). Generac says a 14 or 18 kW unit paired with load management or a soft-start kit may be able to handle that startup (Generac).

Kohler says its 14 kW 14RCA can get a 5-ton air conditioner going and keep it running with ease, with the actual electrical requirements set by the appliance specifications (Kohler). For the 240-volt single-phase configuration, Kohler rates peak motor starting at 33 kilovolt-amperes at 60 Hz, with voltage falling by 35 percent under that rating condition (Kohler). Generac says its 18 kW Guardian 7226 can provide backup power to a 5-ton air conditioner (Generac). Generac says an authorized Generac seller measures the watts appliances draw at startup and during operation to verify the generator's size in a professional site survey (Generac).

Fuel use on propane and natural gas

Generac gives the Guardian 7223's propane burn as 1.81 gallons an hour at half load and 3.07 gallons an hour at full load (Generac). For that same unit on natural gas, Generac lists 195 cubic feet an hour at half load and 256 at full load (Generac). The Guardian 7226 uses 1.7 gallons of propane an hour at half load and 3.02 at full load, according to Generac (Generac). Its half-load natural gas consumption is 169 cubic feet an hour (Generac).

Kohler rates fuel consumption for the 14RCA at 60 Hz in cubic feet per hour (Kohler). On natural gas, it uses 124 cubic feet an hour at half load and 193 at full load (Kohler). On propane, it uses 60 cubic feet an hour at half load and 81 at full load (Kohler). Kohler also lists the 14RCA at a quarter load, when it uses 93 cubic feet of natural gas an hour or 45 cubic feet of propane an hour (Kohler).

Carbon monoxide and backfeeding

Never operate a generator inside a home, garage, basement or other enclosed area (OSHA). Carbon monoxide can accumulate even with the doors and windows open, and a generator must never run outdoors near openings that could admit exhaust, including vents (OSHA). A generator must never feed the house wiring directly without a transfer switch installed by a qualified electrician (OSHA). If the house wiring is not isolated from the grid, the generator may send power far down the utility's lines, putting line workers and others at risk of electrocution (OSHA).

Frequently asked

Can central air and an electric dryer share standby power?

Generac uses the example of central air and an electric dryer starting together to show how its Load Manager handles competing loads (Generac). If the generator is close to overload, the device can temporarily pause the circuit assigned lower priority while the other equipment stays powered (Generac).

Does a 14 kW standby generator always deliver 14 kW on natural gas?

No. Generac rates the Guardian 7223 at a continuous maximum of 14 kW on natural gas (Generac). Kohler rates the 120/240-volt single-phase 14RCA at 12 kW on natural gas and 14 kW on propane (Kohler).

How much fuel does the 14RCA use during an exercise cycle?

Kohler lists an hourly rate of 60 cubic feet on natural gas and 30 cubic feet on propane during exercise at 60 Hz (Kohler). During an outage at full load, its hourly rates are 193 cubic feet on natural gas and 81 on propane (Kohler).

Do I need to call a pro for this?

Yes. The work belongs to a licensed contractor. Generac calls for professional installation of its standby generators and a professional load analysis to size the unit and any load controls (Generac). A qualified electrician must install the transfer switch before the generator connects to the home's electrical system (OSHA).

Related

Need a generator supplied? Blume can supply a generator; the electrical installation is referred to a licensed electrician. Blume Mechanical Service, license CAC-1822618, serves Pinellas, Hillsborough and Pasco counties.

Sources: Generac, Guardian 7223, https://www.generac.com/residential-products/standby-generators/gaseous/14kw-standby-generator-wifi-enabled-7223/ · Generac, Guardian 7226, https://www.generac.com/residential-products/standby-generators/gaseous/18kw-standby-generator-wifi-enabled-7226/ · Generac, Guardian 7226 air conditioning and coverage, https://www.generac.com/residential-products/standby-generators/gaseous/18kw-standby-generator-wifi-enabled-7226/ · Generac, standby generator sizing, https://www.generac.com/resources/home-management/what-size-generator-do-i-need/ · Kohler, 14RCA and 14RCAL specifications, https://resources.kohler.com/power/kohler/residential/pdf/g4270.pdf · Tampa Electric, Hurricane Milton restoration, https://www.tampaelectric.com/mediacenter/2024/Tampa-Electric-Achieving-Power-Restoration-Milestones-After-Hurricane-Milton/ · OSHA, generator safety, https://www.osha.gov/etools/hurricane/activity-sheets/operation-specific/confined-space-entry