HVAC, explained
What a 24 to 26 kW home standby generator can run
Yes, the 26 kW Generac Guardian 7291 on propane has a 26,000-watt continuous rating, above the 9,050 running watts and 15,750 watts at AC startup in a sample load built from Generac's figures (Generac). That estimate pairs a 40,000 BTU central air conditioner with a refrigerator/freezer, furnace fan, TV and sump pump that are already running when the AC starts (Generac). Briggs & Stratton says it designed every PowerProtect+ model, including its 26 kW unit, to start a 5-ton AC (Briggs & Stratton). Generac rates its Guardian 7291 for up to 26 kW of continuous output on propane and 22.5 kW on natural gas (Generac).
Florida electricity customers averaged 19.1 hours without power in 2022 (EIA). For outage planning, running watts tell you what the equipment draws once it is on, and additional starting watts tell you how much extra power a motor briefly needs to get going (Generac). Generac lists a 10,000 BTU window air conditioner at 1,200 running watts plus 1,800 additional starting watts (Generac).
What four household essentials draw
Generac's worksheet assigns 700 running watts to a refrigerator/freezer, 800 to a half-horsepower furnace fan, 500 to a TV and 1,050 to a half-horsepower sump pump (Generac). Together those four draw 700 + 800 + 500 + 1,050 = 3,050 running watts in the example (Generac). The worksheet also includes a window AC, and Generac's typical-load table puts a 10,000 BTU window unit at 1,200 running watts and 1,800 additional starting watts (Generac). Generac's example lists 4,250 total running watts, which is 3,050 for those four plus 1,200 for the window air conditioner (Generac). The furnace fan has the biggest extra starting draw in the example, at 2,350 watts, so the worksheet adds 4,250 + 2,350 to reach 6,600 watts (Generac). Generac's example adds only the single highest starting figure, 2,350 watts, to the running total (Generac).
What central air adds to the load
Generac's typical figures for a 24,000 BTU central AC are 3,800 watts while running and another 4,950 at startup (Generac). For a 40,000 BTU central AC, the corresponding estimates are 6,000 running watts and another 6,700 to start (Generac). In a hypothetical house with the four essentials in the example and the 40,000 BTU AC, the steady load would be 3,050 + 6,000 = 9,050 watts (Generac). If the AC starts while those four loads are already running, the estimate rises to 9,050 + 6,700 = 15,750 watts during startup (Generac). An electric water heater adds another 4,000 running watts if it is on at the same time, bringing the running estimate to 9,050 + 4,000 = 13,050 watts (Generac). Those examples use typical appliance draws (Generac).
What the fuel and model change
Generac's Guardian 7291 specifications list a main line circuit breaker value of 110 and a maximum continuous power of 26,000 watts on propane and 22,500 on natural gas (Generac). Kohler rates the single-phase, 120/240-volt 26RCA at 24 kW on natural gas and 26 kW on propane, with a 125-amp line breaker for that configuration (Kohler). Kohler's general guideline for the 26RCA is to reduce rated output by 2 percent for every 10°F above 60°F (Kohler). Kohler's standby rating assumes a reliable utility supply and variable loads averaging 80 percent of rated load over the outage (Kohler).
Fuel use rises with electrical demand
At half load the Guardian 7291 uses 188 cubic feet of natural gas per hour, according to Generac, and at full load it uses 333 cubic feet per hour (Generac). On propane, Generac lists 2.06 gallons per hour at half load and 3.63 gallons per hour at full load for the same model (Generac). Kohler's 60 Hz figures for the 26RCA are 180 cubic feet of natural gas per hour at half load and 290 at full load (Kohler). Kohler lists propane use of 85 cubic feet per hour at half load and 129 at full load for that unit (Kohler).
Transfer equipment and outage safety
Tampa Electric calls for a licensed electrician to install a permanent standby generator with a double-throw transfer switch (Tampa Electric). A correctly installed switch keeps the generator isolated from the utility grid, preventing backfeed that could endanger lineworkers (Tampa Electric). Never connect a portable generator directly to the home's wiring (Tampa Electric). Never run a portable unit indoors, in a garage, near AC ducts or in any other enclosed area (Tampa Electric). Carbon monoxide from the exhaust can kill (Tampa Electric). In Generac's automatic standby setup, the generator detects a utility outage and starts, then the transfer switch routes standby power to the home until utility service returns (Generac). In Generac's installation sequence, the transfer switch can go beside the main breaker box or replace it. The wiring runs through conduit before the fuel line goes in (Generac).
Frequently asked
How much starting power does the Guardian 7291 have?
Generac lists 55.2 kVA of starting power and a 230 locked-rotor amp starting figure for the Guardian 7291 (Generac).
What is the Kohler 26RCA motor starting rating?
Kohler gives a peak motor starting figure of 39 kVA for the single-phase, 240-volt configuration at 60 Hz, measured at a 35 percent voltage dip (Kohler).
Can I keep the heat pump on during an outage?
Generac's typical heat pump example is 4,700 running watts plus 4,500 additional starting watts (Generac).
How loud is the Briggs & Stratton 26 kW model?
Briggs & Stratton lists 67 dB(A) for the PowerProtect+ 26 kW during normal operation (Briggs & Stratton).
Do I need to call a pro for this?
Yes. The work belongs to a licensed contractor. Tampa Electric specifies a double-throw transfer switch and installation by a licensed electrician for permanent standby generators (Tampa Electric).
Related
- What a 20 kW home standby generator can run
- Air conditioner starting current and generator size
- Generator fuel for a long outage: propane, gas, diesel
- Generator carbon monoxide and backfeeding: safe placement and wiring
- Running an AC on a home generator: load management
- AC Tonnage and Sizing: What 3, 4 and 5 Tons Mean in Florida
- Adding air conditioning to a commercial generator
Need a generator supplied? Blume can supply a generator; the electrical installation is referred to a licensed electrician. Blume Mechanical Service, license CAC-1822618, serves Pinellas, Hillsborough and Pasco counties.
Sources: Generac, Your Guide to Home Standby Generator buyer's guide brochure, https://www.generac.com/globalassets/residential/home-standby-generators/buyers-guide/hsb_buyersguide_brochure_2024_v6.pdf · Kohler, 26RCA/26RCAL Specification Sheet G4-315, https://resources.kohler.com/power/kohler/residential/pdf/g4315.pdf · Briggs and Stratton Energy Solutions, PowerProtect+ 26kW Home Standby Generator, https://energy.briggsandstratton.com/en-us/products/powerprotectplus-26kw-home-standby-generator · EIA, U.S. electricity customers averaged five and one-half hours of power interruptions in 2022, https://www.eia.gov/todayinenergy/detail.php?id=61303 · Generac, Guardian 7291 product specifications, https://www.generac.com/residential-products/standby-generators/gaseous/26kw-standby-generator-with-whole-house-switch-wifi-enabled-7291/ · Tampa Electric, Home Safety, https://www.tampaelectric.com/safety/home-safety/