Blume Mechanical ServiceBlumeMechanical Service
Outdoor condenser unit, close-up

HVAC, explained

What a 10 kW home standby generator can run

In Generac's 1,550-square-foot example, 10 kW is enough for lights, refrigeration and small appliances on essential circuits (Generac). Generac rates its Guardian 7171 for up to 10,000 continuous watts on propane and 9,000 on natural gas (Generac). For a sense of scale, Generac uses typical running figures of 700 watts for a refrigerator or freezer and 800 watts for a one-third-horsepower sump pump, both of which need extra power at startup (Generac). In Generac's 1,550 sq. ft. example, 10 kW suits essential circuits such as lights, refrigeration and small appliances, while central air or a well pump moves the size to 14 to 18 kW, though with one or two Load Managers Generac says a 10 to 14 kW unit can give the AC and well pump priority (Generac).

Hurricane Ian knocked out service for more than 2.6 million Florida electricity customers in September 2022, and some went more than two weeks without power (EIA). Generac lists the refrigerator, freezer and LED lighting as essentials, and central air, an electric range, a well pump, an EV charger and an electric dryer as heavy hitters (Generac).

What fits on a 10 kW standby generator?

Generac puts refrigeration, LED lighting, internet equipment and sump pumps among the essentials to consider when sizing standby power (Generac). Its typical appliance figures put a half-horsepower sump pump at 1,050 running watts with another 2,200 watts needed at startup (Generac). A one-third-horsepower well pump is a separate example at 1,000 running watts with 2,200 extra watts to start (Generac).

Generac’s electric water heater example uses 4,000 running watts and needs no extra watts at startup (Generac). Generac places a microwave, a toaster oven, a garage door opener and a small window air conditioner in its comfort tier, one step above the essentials (Generac). For motors, Generac says the burst needed to start is typically two to three times what the motor draws once running, and its formula for total power adds every running wattage to the single highest starting burst (Generac). An electric range, clothes dryer or EV charger can also put the home in a higher-demand category than an essentials-only setup (Generac).

Central AC has to get through startup

Generac gives about 3.5 to 5 kW as typical running demand for a 3-ton central AC, with starting demand that can reach 15 to 18 kW (Generac). Generac says a mid-sized 14 kW or 18 kW generator, paired with a Load Manager, or alternatively a Soft Start kit, can take up that startup surge (Generac). Generac points to appliance nameplates and manufacturer specifications when assessing starting and running watts (Generac).

Kohler says its 14 kW 14RCA can both start and power a 5-ton AC, subject to the actual requirements of the appliance (Kohler). Generac says an on-site load analysis can inform its recommendation for generator size and Load Manager setup (Generac).

What changes with load management?

Refrigerators, sump pumps and air conditioners cycle on and off. With load management, lower-priority appliances can run while higher-priority ones are idle, so a smaller generator may suffice (Kohler). Generac’s Load Manager can temporarily pause a lower-priority appliance when the system is close to overload, such as when the central AC and an electric dryer try to start together (Generac). For its 1,550-square-foot example, Generac says a 10 to 14 kW unit with one or two Load Managers can prioritize central air and the well pump (Generac). A professional can measure the home’s electrical panel loads on site and recommend a generator size and Load Manager configuration for that home (Generac).

Transfer switches and carbon monoxide

Tampa Electric calls for a licensed electrician to install a permanent standby generator with a double-throw transfer switch (Tampa Electric). A properly installed switch keeps generator power off utility lines during an outage, preventing dangerous backfeed that can endanger lineworkers (Tampa Electric). Never tie a portable generator into a household circuit or connect it at the breaker panel, fuse box or meter box (Tampa Electric). Never run a portable generator inside the house, in a garage or in another enclosed space (Generac). Its exhaust can cause serious carbon monoxide poisoning (Generac).

Frequently asked

How many watts does a refrigerator use?

Generac’s typical sizing example is 700 watts to run a refrigerator or freezer, plus 2,200 additional watts at startup (Generac). The higher demand comes briefly when the motor starts (Generac). The actual figures for your appliance are what the installer needs for sizing (Generac).

Does a 10 kW generator give me the same power on natural gas and propane?

Generac rates the Guardian 7171 for up to 9,000 continuous watts on natural gas and up to 10,000 on propane (Generac). That gives the same model a different capacity depending on which fuel supplies it (Generac).

Will a 10 kW generator run my whole house?

Generac treats 10 kW as an essentials size in its example for a 1,550-square-foot home (Generac). It puts homes that also want central air or a well pump in the 14 to 18 kW range in that example (Generac). The decision comes down to which equipment needs power together and the loads that equipment draws (Generac).

What does the 10 kW Guardian use at full load?

Generac lists 127 cubic feet of natural gas per hour at full load for model 7171 (Generac). On propane, the same model uses 1.48 gallons per hour at full load (Generac). At half load, the figures are 101 cubic feet of natural gas per hour or 0.97 gallons of propane per hour (Generac).

Do I need to call a pro for this?

Yes. The work belongs to a licensed contractor. Tampa Electric calls for a permanent standby system installed by a licensed electrician and equipped with a double-throw transfer switch (Tampa Electric). The professional load assessment covers both steady operation and motor startup so the installer can size the generator for the circuits it will serve (Generac).

Related

Need a generator supplied? Blume can supply a generator; the electrical installation is referred to a licensed electrician. Blume Mechanical Service, license CAC-1822618, serves Pinellas, Hillsborough and Pasco counties.

Sources: Generac, Guardian 7171 product specifications, https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-10kw-wifi-enabled-7171/ · Generac, Home standby generator sizing, https://www.generac.com/resources/home-management/what-size-generator-do-i-need/ · Generac, Home standby generator buyer’s guide, https://www.generac.com/globalassets/residential/home-standby-generators/buyers-guide/hsb_buyersguide_brochure_2024_v6.pdf · Kohler, 14RCA and 14RCAL specifications, https://resources.kohler.com/power/kohler/residential/pdf/g4270.pdf · Kohler, RXT transfer switch operation and installation manual, https://resources.kohler.com/power/kohler/residential/pdf/tp6807.pdf · EIA, U.S. electricity customer interruptions in 2022, https://www.eia.gov/todayinenergy/detail.php?id=61303 · Tampa Electric, Storm Center, https://www.tampaelectric.com/stormcenter · Generac, Portable generator FAQ, https://www.generac.com/portable-power-solutions/faq/

Search Google for what can a 10kw generator run