HVAC, explained
Well pumps and water heaters on generator power
Yes, if the generator can cover the load: in Generac's typical figures a 1/3 hp well pump needs 1,000 running watts plus 2,200 starting watts and an electric water heater needs 4,000 running watts with no starting watts, so 1,000 + 4,000 + 2,200 comes to 7,200 watts before any other circuits (Generac). A standby setup can also cover the well pump as an essential circuit without including every appliance in the house (Generac).
Hurricane Milton left nearly 600,000 outages on Tampa Electric's system, mainly after uprooted trees and storm debris brought down overhead lines and poles (Tampa Electric). Ready.gov says a power outage may disrupt water, and it advises listing the items you rely on electricity to run (Ready.gov).
What a well pump needs at startup
Generac calls the power an appliance needs once it is operating its running wattage, also known as rated watts (Generac). For motor-driven equipment, Generac uses starting watts to mean the extra power needed briefly as the motor starts and gives 2 to 3 seconds as its general estimate (Generac). In Generac's typical example for a 1/3 hp well pump, the pump takes 1,000 watts while running, with another 2,200 watts required at startup (Generac). In Generac's table the 1/3 hp well pump shows 1,000 running watts and 2,200 additional starting watts (Generac). For its estimate, Generac adds the running wattages of the loads being backed up and then includes the largest single starting allowance (Generac).
Franklin Electric rates its 1 hp model 2445089003GS for 230 volts AC and lists 8.2 amps under full load and 10.4 amps at service factor load (Franklin Electric).
Well pumps come in many sizes, and the backup supply has to suit the pump’s voltage, running wattage and startup surge (Portland General Electric). Most well pumps are wired into the home’s panel, according to Portland General Electric, and supplying that panel from a portable generator requires a transfer switch (Portland General Electric).
What an electric water heater adds
Generac gives 4,000 running watts as its typical electric water heater example and assigns that example zero extra watts for startup (Generac). In Generac's worksheet method, the running watts of every item being backed up are added together, so the heater's 4,000 running watts count toward the total (Generac).
A. O. Smith rates its PELBU-50 100 residential electric tank model at 4,500 watts maximum on a 240-volt supply (A. O. Smith). The same maker rates its R4LA-240E 100 residential electric tankless model at a maximum of 24,000 watts, also at 240 volts (A. O. Smith). These two models share the same supply voltage and have different maximum loads (A. O. Smith).
A hybrid heat pump water heater can switch automatically to electric resistance when demand for hot water is high (ENERGY STAR). Depending on the operating mode, a heat pump water heater can heat the tank with the heat pump alone or with the electric element alone (ENERGY STAR).
Backing up the pump as an essential circuit
Generac includes a well pump, refrigerator, furnace and sump pump among the circuits its PowerPact 7.5 kW model 6998 is intended to back up in an essential-circuit installation (Generac). In a setup with an automatic transfer switch, Generac's standby system takes over by sending generator power to the house after the generator starts and keeps supplying it until utility power returns (Generac).
Generac also offers a setup with its Guardian 18 kW model 7228 and a whole-house transfer switch, paired with its smart management modules (Generac). Generac says the modules can cycle power to different appliances as needed and let the household assign priorities (Generac).
Which loads belong on the backup plan?
Ready.gov recommends planning around the equipment the household relies on during an outage, including electrically powered medical devices and medicines that need refrigeration (Ready.gov). Generac lists a well pump among the essential circuits its PowerPact model is meant to back up (Generac). Generac says its worksheet only helps narrow down generator size and is not a substitute for a detailed estimate (Generac).
Carbon monoxide and backfeeding
Never run a portable generator in the house, in a garage or anywhere else indoors (Tampa Electric; Ready.gov). Portable generators should always run outside, at least 20 feet from attached garages, doors and windows (Ready.gov). Generator exhaust can produce deadly carbon monoxide, a gas with no smell or color (Tampa Electric; Ready.gov).
Tampa Electric prohibits connecting portable generators to household circuits or to the meter box, fuse box or breaker panel (Tampa Electric). Backfeeding can put utility crews at risk while they work on the lines (Tampa Electric). For permanent standby systems, Tampa Electric calls for a licensed electrician to install the generator and a double-throw transfer switch (Tampa Electric). The switch keeps generator power isolated from the utility grid, preventing backfeed (Tampa Electric).
Frequently asked
Do I need to call a pro for this?
Yes. The work belongs to a licensed contractor. Tampa Electric says a licensed electrician must install a permanent standby generator, including its double-throw transfer switch (Tampa Electric).
What can frequent well pump starts tell me?
Amtrol says rapid pump cycling or low water pressure can be signs that a well pressure tank needs replacement (Amtrol).
How much emergency water should a household have?
Ready.gov recommends allowing at least 1 gallon per household member for each day, for several days, to cover drinking and sanitation (Ready.gov). Very hot weather can double how much water people need (Ready.gov). Children, people who are ill and nursing mothers may need extra (Ready.gov).
What if the electricity has just come back?
Tampa Electric recommends waiting 5 to 10 minutes after power is restored, then turning appliances and electronics back on, to help avoid damage (Tampa Electric). The delay can help prevent damage, and Ready.gov says brief surges can happen when utility power returns (Tampa Electric; Ready.gov).
Related
- What a 14 to 18 kilowatt home standby generator can run on each fuel
- Generator carbon monoxide and backfeeding: safe placement and wiring
- What to put on a home generator
- Freezers and fridges on a generator: food safety
- Restarting an air conditioner after a power outage
- Generator fuel for a long outage: propane, gas, diesel
Need a generator supplied? Blume can supply a generator; the electrical installation is referred to a licensed electrician. Blume Mechanical Service, license CAC-1822618, serves Pinellas, Hillsborough and Pasco counties.
Sources: Generac, https://www.generac.com/globalassets/residential/home-standby-generators/buyers-guide/hsb_buyersguide_brochure_2024_v6.pdf · Franklin Electric, https://www.franklinwater.com/products/submersible-motors-and-control-boxes/4-inch-submersible-motors/4-inch-induction-motor/4-inch-2-wire-single-phase-models--sku-collection/2445089003gs/ · A. O. Smith, PELBU-50 100, https://www.hotwater.com/products/grid-capable-proline/pelbu-50-100/100362934.html · A. O. Smith, R4LA-240E 100, https://www.hotwater.com/products/tankless-electric-proline/r4la-240e-100/100294820.html · Amtrol, Well Tank Support, https://www.amtrol.com/welltanksupport/ · Ready.gov, Water, https://www.ready.gov/water · Ready.gov, Power Outages, https://www.ready.gov/power-outages · Tampa Electric, Storm Center, https://www.tampaelectric.com/stormcenter · Tampa Electric, Hurricane Milton restoration, https://www.tampaelectric.com/mediacenter/2024/Tampa-Electric-Achieving-Power-Restoration-Milestones-After-Hurricane-Milton/ · Portland General Electric, https://portlandgeneral.com/outages-safety/powering-wells-during-a-power-outage · ENERGY STAR, https://www.energystar.gov/products/heat_pump_water_heaters/how-it-works