HVAC, explained
Restarting an air conditioner after a power outage
After a power outage, Tampa Electric says to wait 5 to 10 minutes, then turn appliances and electronics on individually (Tampa Electric). For AIRSTAGE units, Fujitsu General says the protection circuit prevents a restart for 3 minutes when power returns (Fujitsu General).
Tampa Electric says the wait eases strain on the power system and lets all customers be restored quickly (Tampa Electric). Its storm page gives the same 5-to-10-minute wait as a way to help avoid damage (Tampa Electric).
Wait 5 to 10 minutes before turning things on
Tampa Electric says to wait 5 to 10 minutes after a power outage before individually turning on appliances and electronics (Tampa Electric). The utility explains that waiting eases stress on the power system and helps all customers get power back quickly (Tampa Electric). Its storm page also gives the wait to help avoid damage when power is restored (Tampa Electric).
Mini-split restart delays
For an AIRSTAGE unit, Fujitsu General says the compressor stays off for about 3 minutes if the unit is shut off and then switched straight back on, to prevent fuse blowouts (Fujitsu General). The same FAQ says that once power returns after an interruption, the protection circuit prevents a restart for 3 minutes (Fujitsu General). Copeland says the shutdown devices in its ZP*K3 and ZP*K5 scroll compressors can allow a restart right away, which removes the need for a time delay (Copeland, AE4-1331).
What you may hear after an AIRSTAGE unit starts
Fujitsu General says an AIRSTAGE unit may be especially noisy for roughly 2-3 minutes once it begins operating, which is the sound of coolant moving (Fujitsu General).
Why starting a motor takes a surge of power
Briggs & Stratton describes motor starting power as the momentary surge that heavy motors need to turn on, such as 5-ton air conditioners (Briggs & Stratton). Copeland says that in its single-phase ZP scroll compressors the starting current, also called locked rotor amps, is normally six or more times the rated running amperage and lasts 100 to 300 milliseconds (Copeland, AE4-1331). Copeland adds that this surge may result in significant voltage sag on a poor power supply, and that low starting voltage reduces starting torque (Copeland, AE4-1331). Trane says the start capacitor supplies the energy the compressor needs to begin the cooling cycle, and the run capacitor then keeps the motor going (Trane).
Brief power blips
Copeland says a power interruption shorter than half a second can make a single-phase scroll compressor run in reverse for a time. That does not damage the compressor, and it starts and runs normally once its internal overload resets (Copeland, AE4-1331).
A tripped breaker or blown fuse: testing comes before any reset
When an AIRSTAGE unit does not run at all, its FAQ asks whether there has been a power failure, whether a fuse has blown or a circuit breaker has tripped, and whether the timer is operating (Fujitsu General). For its ZP*K3 and ZP*K5 scroll compressors, Copeland says never to reset a tripped breaker or replace a blown fuse without appropriate electrical testing (Copeland, AE4-1331). Copeland notes that when a breaker trips or a fuse blows, the compressor may have an electrical fault, and that powering up a compressor in that condition "can cause terminal venting," in which the terminal pin loses its seal and oil, refrigerant and debris are ejected. It says this can injure people, and the spray can ignite, causing serious or fatal burns (Copeland, AE4-1331). Copeland limits troubleshooting of these compressors to qualified, authorized HVAC or refrigeration personnel, so this electrical testing is a technician's task, not a homeowner's (Copeland, AE4-1331).
Safety around the capacitor and compressor
Trane warns that touching or mishandling an AC capacitor can cause serious injury or death (Trane). Trane advises against replacing an AC capacitor on your own. It describes capacitors as high-voltage devices that can badly hurt you, even when the power is off (Trane). For its ZP*K3 and ZP*K5 scroll compressors, Copeland's instruction is: "Keep clear of the compressor when power is applied." It says to get away at once if you hear unusual sounds such as sizzling, sputtering or popping, which can mean a terminal pin is about to be ejected, and adds that terminal venting may still occur with no unusual sounds (Copeland, AE4-1331).
Portable generators
If a portable generator runs the house, Tampa Electric says not to connect it to home circuits, a breaker panel, a fuse box or a meter box (Tampa Electric). It also says "DO NOT" run portable generators indoors, in a closed garage, near AC ducts, or in any other enclosed area (Tampa Electric).
Wet equipment after a flood
If the home has flooded, Tampa Electric says not to turn the power back on yourself. A licensed electrician should check the home and re-energize the circuits (Tampa Electric). Tampa Electric also says not to plug in wet appliances until a technician can check them and find them safe (Tampa Electric), and not to touch electrical devices while standing in water (Tampa Electric).
When to call a technician
Trane lists a slow start or no start, a burning smell, and smoke among the symptoms of a bad capacitor, and says these signs mean you should hire an HVAC technician (Trane). Trane says capacitor failure is among the most frequent reasons an air conditioner breaks down, especially in summer (Trane). Trane advises calling an experienced, licensed HVAC technician if the air conditioner has problems (Trane). Copeland limits troubleshooting of its ZP*K3 and ZP*K5 scroll compressors to qualified, authorized HVAC or refrigeration personnel. Its diagnostic steps, such as checking voltage to the unit and the compressor's internal overload, are a technician's job, not a homeowner's (Copeland, AE4-1331).
Frequently asked
How long should I wait before turning the air conditioner on after power returns?
Tampa Electric says to wait 5 to 10 minutes after power is restored, then turn on appliances and electronics individually (Tampa Electric).
Why does an AIRSTAGE mini-split wait about 3 minutes?
Fujitsu General says the protection circuit prevents a restart for 3 minutes after power returns (Fujitsu General).
What if the unit still will not start?
For an AIRSTAGE unit that does not run at all, Fujitsu General's FAQ lists a blown fuse or tripped circuit breaker among the things to ask about (Fujitsu General). For its ZP*K3 and ZP*K5 scroll compressors, Copeland says a breaker must never be reset, and a blown fuse never replaced, without appropriate electrical testing, and limits troubleshooting to qualified, authorized HVAC or refrigeration personnel, so this testing is a technician's task, not a homeowner's (Copeland, AE4-1331). Trane advises calling an experienced, licensed HVAC technician if the air conditioner has problems (Trane).
Do I need to call a pro for this?
Maybe. After an outage, Tampa Electric says to wait 5 to 10 minutes and then switch appliances and electronics on one at a time (Tampa Electric). Trane warns that handling an AC capacitor badly, or touching it, can cause serious injury or death (Trane). For its ZP*K3 and ZP*K5 scroll compressors, Copeland says never to reset a tripped breaker or replace a blown fuse without appropriate electrical testing (Copeland, AE4-1331). Trane recommends that an air conditioner with problems be looked at by an experienced, licensed HVAC technician (Trane), and a licensed contractor should handle any electrical or refrigerant work.
Related
- Generator carbon monoxide and backfeeding: safe placement and wiring
- Thermostat settings on backup power: 78°F, humidity and mold
- First 72 hours of a power outage: HVAC and generator steps
Need a technician to check the system after an outage? Blume works on HVAC and refrigeration equipment and serves Pinellas, Hillsborough and Pasco counties. Call (727) 330-9131.
Sources: Tampa Electric, Storm Center, https://www.tampaelectric.com/stormcenter · Briggs & Stratton Energy Solutions, PowerProtect+ Standby Generators: A Buyer's Guide, https://energy.briggsandstratton.com/en-us/resources/article-categories/resource-articles/guide-to-generators · Trane, AC Capacitors: What They Are and Why They Matter, https://www.trane.com/residential/en/resources/blog/air-conditioner-capacitors-what-they-are-and-why-theyre-such-a-big-deal/ · Fujitsu General, AIRSTAGE FAQs & Troubleshooting, https://www.airstagehvac.com/us/support/faq/halcyon/troubleshooting.html · Copeland, Application Engineering Bulletin AE4-1331 R9, ZP16 to ZP44K3E and ZP14 to ZP61K5E R-410A 1.5 to 5 Ton Copeland Scroll Compressors, https://apps.copeland.com/Publications/AEB/AE4_1331_R9.pdf