HVAC, explained
Legionella cooling tower water management
Legionnaires' disease is a serious pneumonia caused by a type of bacteria called Legionella (CDC). People can get it when they breathe in mist that contains the bacteria (CDC). The CDC says the key to preventing it is to reduce the risk of Legionella growth and spread (CDC).
This page sets out the steps the CDC publishes for controlling Legionella in cooling towers. Where no number appears here, ask your provider for the detail.
How Legionnaires' disease spreads and what to watch for
People can get Legionnaires' disease when they breathe in mist that contains the bacteria (CDC). The CDC says the key to preventing Legionnaires' disease is to reduce the risk of Legionella growth and spread (CDC). Legionnaires' disease is caused by Legionella bacteria that grow in warm water (NYC DOHMH). Most people exposed to Legionella bacteria do not develop Legionnaires' disease (NYC DOHMH). Illness usually occurs after high or repeated exposure, especially in people at increased risk (NYC DOHMH).
Legionnaires' disease symptoms include fever, chills, muscle aches, and cough (NYC DOHMH). Legionnaires' disease can be effectively treated if diagnosed early (NYC DOHMH). Follow your doctor's advice if you have these symptoms.
The bacteria that cause Legionnaires' disease do not spread through cooled air from air conditioners (NYC DOHMH).
Use a water management program
The CDC recommends using a water management program to establish, track, and improve cooling tower operation and maintenance (CDC). The CDC toolkit calls an effective water management program the primary strategy to control Legionella growth and spread (CDC).
Water management programs can reduce the risk of Legionella growing and spreading in water systems and devices (CDC). Write the program down, so every technician works from the same list of tasks.
Operate at the lowest possible water temperature
The CDC says cooling tower systems should run at the lowest possible water temperature (CDC).
No number is given here, so ask your service provider to set a target for each tower and write it into your program.
Clean and disinfect at least once a year
The CDC says cooling tower equipment should be removed from service, cleaned, and disinfected at least once a year (CDC).
Schedule that work with a qualified provider, and ask which cleaning and disinfecting method they use.
Circulate water through all equipment
The CDC says water should be circulated through all cooling tower system equipment, including bypass or standby components (CDC).
When you walk the system with your technician, check that standby and bypass parts are on the circulation list.
Monitor inhibitors and get the industry guideline
The CDC says scale and corrosion inhibitor levels should be monitored frequently, based on water quality measurements (CDC). The CDC refers operators to a separate industry guideline for instructions on each control response (CDC).
Ask your provider for that guideline and keep a copy with your program file.
Testing schedule and action levels from one college
The college's own schedule tests every 90 days while its cooling towers are in service (Hostos Community College). That is one college's schedule, not a general requirement.
A college page says action is recommended for findings of at least 100 CFU/mL (Hostos Community College). Ask your provider which action levels apply to your towers, and write the answers down.
Culture tests show which cooling towers had live Legionella bacteria growing when the water sample was collected (NYC DOHMH).
Who to call for water work and HVAC work
For HVAC mechanical service, have a licensed HVAC technician check the equipment. Ask a water treatment provider about sampling, dosing and the records they keep.
Keep water treatment contacts and HVAC service contacts on separate lines, so each task has a clear owner.
New York State and New York City rules
The rules in this section apply only in New York State and New York City, so check which rules cover a tower in Florida with your local health authority.
Cooling towers in New York State must be inspected before seasonal start-up and every 90 days while in use (NYSDOH). Registries for cooling towers in New York State must be updated every 90 days while the tower is operational (NYSDOH). Cooling towers in New York State must obtain a certification by November 1 of each year (NYSDOH). Each active cooling tower in New York State must have an updated Maintenance Program and Plan (NYSDOH). Cooling towers are tested for Legionella to assess the effectiveness of routine disinfection and maintenance (NYSDOH).
A New York City law requires building owners to register, maintain, and test the water in their cooling tower systems (NYC DOHMH). NYC inspections include a review of each system's Maintenance Program and Plan and operational records (NYC DOHMH). The NYC Maintenance Program and Plan explains how the system is monitored, cleaned, and disinfected (NYC DOHMH). Beginning May 8, 2026, NYC requires Legionella sampling monthly, with no more than 31 days between samples (NYC DOHMH). In NYC, a building's qualified person must report the date of each Legionella sample (NYC DOHMH).
Frequently asked
What is Legionnaires' disease?
Legionnaires' disease is a serious pneumonia caused by a type of bacteria called Legionella (CDC). People can get it when they breathe in mist that contains the bacteria (CDC).
What is a water management program?
The CDC recommends using a water management program to establish, track, and improve cooling tower operation and maintenance (CDC). The CDC toolkit calls it the primary strategy to control Legionella growth and spread (CDC).
How often should cooling tower equipment be cleaned?
The CDC says cooling tower equipment should be removed from service, cleaned, and disinfected at least once a year (CDC). Ask your provider which disinfecting method they use and how they record the job.
What temperature should a cooling tower run at?
The CDC says cooling tower systems should run at the lowest possible water temperature (CDC). No number is given here, so ask your service provider what target applies to your system.
Do standby parts need to circulate water?
The CDC says water should be circulated through all cooling tower system equipment, including bypass or standby components (CDC). Check the circulation list with your technician at each visit.
How often should a cooling tower be tested for Legionella?
The college's own schedule tests every 90 days while its cooling towers are in service (Hostos Community College). That is one college's schedule, not a general requirement.
Related
- Commercial building energy benchmarking basics
- Rooftop unit replacement efficiency: what to check
- Cooling Tower Replacement: When It Is Considered and What It Involves
For HVAC mechanical service, call Blume Mechanical Service (license CAC-1822618). Blume repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: CDC — Controlling Legionella in Cooling Towers (https://www.cdc.gov/control-legionella/php/toolkit/cooling-towers-module.html) · CDC — Water Management Program Toolkit (https://www.cdc.gov/control-legionella/php/toolkit/wmp-toolkit.html) · CDC — About Legionnaires' Disease (https://www.cdc.gov/legionella/about/index.html) · Hostos Community College — Legionella Testing & Cooling Towers (https://www.hostos.cuny.edu/Administrative-Offices/Division-of-Administration-and-Finance/Environmental-Health-Safety/Legionella-Testing-Cooling-Towers) · New York State Department of Health (NYSDOH) — Protection Against Legionella: Cooling Tower Requirements (https://healthweb-back.health.ny.gov/environmental/water/drinking/legionella/cooling_towers.htm) · NYC Department of Health and Mental Hygiene (NYC DOHMH) — Cooling Towers: Maintenance Program and Plan (https://www.nyc.gov/site/doh/business/permits-and-licenses/cooling-towers.page) · NYC Department of Health and Mental Hygiene (NYC DOHMH) — Legionnaires' disease (https://www.nyc.gov/site/doh/health/health-topics/legionnaires-disease.page)