HVAC, explained
Commercial building energy benchmarking basics
ENERGY STAR Portfolio Manager is used to manage energy, water, waste, and greenhouse gas emissions (ENERGY STAR). Benchmarking starts with your utility bills and some basic information about your building (ENERGY STAR). A building with an ENERGY STAR score of 75 or higher may be eligible for certification (ENERGY STAR).
Facility managers who run one or more buildings may want to track energy use. The sections below cover what ENERGY STAR Portfolio Manager tracks, what data it needs, how to read the score, and which eligibility checks apply.
What Portfolio Manager tracks
ENERGY STAR Portfolio Manager is used to manage energy, water, waste, and greenhouse gas emissions (ENERGY STAR). Energy is one of the four areas the tool covers (ENERGY STAR).
Enter each building's data in the same order every time, so the records line up from one building to the next.
Gathering bills and building details
Benchmarking starts with your utility bills and some basic information about your building (ENERGY STAR). The information Portfolio Manager requires varies depending on the type of property (ENERGY STAR).
Check the data requirements for each property type before you enter any numbers.
Gross floor area and Source EUI
All properties are eligible to receive metrics such as Source EUI (ENERGY STAR). Properties receive these metrics by providing gross floor area and 12 months of energy usage (ENERGY STAR).
Take the 12 months of usage from the utility bills for the building.
Energy data for a 1–100 score
A 1–100 score needs at least 12 full consecutive calendar months of energy data for all active meters and all fuel types (ENERGY STAR). The property must include all energy it uses, such as electricity, gas, oil, steam and onsite renewable energy (ENERGY STAR).
If a meter was not active for all 12 months, check the program's current requirements before you enter its data.
How commercial buildings use energy
EIA estimated that 5.9 million U.S. commercial buildings consumed 6.8 quadrillion British thermal units of energy in 2018 (EIA). The 2018 survey figures describe the national total (EIA).
In the 2018 survey, electricity and natural gas were the main energy sources for U.S. commercial buildings (EIA). In 2018, space heating accounted for close to one-third of end-use consumption in U.S. commercial buildings (EIA). In 2018, space heating was the most energy-intensive end use in U.S. commercial buildings, especially in colder climates (EIA).
These are national figures, so they describe the whole country rather than your building.
Eligibility checks for a 1–100 score
A building must be in operation at least 30 hours per week to receive a 1–100 score (ENERGY STAR). A parking garage cannot be bigger than the building (ENERGY STAR). The rest of a building may house other property types, and it can still receive a 1–100 score (ENERGY STAR).
A data center has no square-foot minimum for a 1–100 score (ENERGY STAR).
Reading the score
ENERGY STAR says a higher score is better than average, and a lower score is worse (ENERGY STAR).
When the score changes, compare the change with your bills and your operating schedule before you act on it.
Certification
A building with an ENERGY STAR score of 75 or higher may be eligible for certification (ENERGY STAR). Eligible commercial buildings must earn a 1–100 ENERGY STAR score of 75 or higher to earn the certification (ENERGY STAR). Before applying, a building's application must be verified by a Professional Engineer or Registered Architect (ENERGY STAR).
EPA conducts regular audits to ensure adherence with program guidelines (ENERGY STAR).
Frequently asked
What does ENERGY STAR Portfolio Manager track?
It is used to manage energy, water, waste, and greenhouse gas emissions (ENERGY STAR). Energy is one of those four areas (ENERGY STAR).
What score qualifies a building for certification?
A building with an ENERGY STAR score of 75 or higher may be eligible for certification (ENERGY STAR). The word may matters, so check the current certification requirements before you apply.
Is a higher ENERGY STAR score better?
ENERGY STAR says a higher score is better than average, and a lower score is worse (ENERGY STAR).
What do I need to start benchmarking?
Benchmarking starts with your utility bills and some basic information about your building (ENERGY STAR). The required information varies depending on the type of property (ENERGY STAR).
Who verifies a certification application?
Before applying, a building's application must be verified by a Professional Engineer or Registered Architect (ENERGY STAR).
How much energy do U.S. commercial buildings use?
EIA estimated that 5.9 million U.S. commercial buildings consumed 6.8 quadrillion British thermal units of energy in 2018 (EIA). These are national totals, not figures for one building type or region.
Related
- Rooftop unit replacement efficiency: what to check
- Commercial refrigeration and food safety temperatures
- Commercial Heat Pumps: Types, Where They Fit, What to Check
If a benchmarked building has an HVAC or refrigeration problem, call Blume Mechanical Service (license CAC-1822618). Blume repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: U.S. EPA ENERGY STAR — Benchmark Your Building With Portfolio Manager (https://www.energystar.gov/buildings/benchmark) · U.S. EPA ENERGY STAR — ENERGY STAR Portfolio Manager: What data is required to benchmark your property? (https://portfoliomanager.energystar.gov/pm/dataCollectionWorksheet) · U.S. EPA ENERGY STAR — Eligibility Criteria for the 1–100 ENERGY STAR Score (https://www.energystar.gov/buildings/facility-owners-and-managers/existing-buildings/use-portfolio-manager/understand-metrics/eligibility) · U.S. EPA ENERGY STAR — ENERGY STAR Certification (https://www.energystar.gov/about/how-energy-star-works/energy-star-certification) · U.S. EIA — Commercial Buildings Energy Consumption Survey (CBECS) (https://www.eia.gov/consumption/commercial/) · U.S. EIA — U.S. commercial buildings consumed more fuel for space heating than anything else in 2018 (https://www.eia.gov/todayinenergy/detail.php?id=55199)