Some estimates cited by the U.S. Department of Energy say most residential HVAC systems are installed improperly (U.S. Department of Energy). The DOE names too little airflow across the indoor coil and an incorrect refrigerant charge among the problems behind suboptimal performance (U.S. Department of Energy).
The Florida Solar Energy Center at the University of Central Florida conducted a study funded by the U.S. Department of Energy (Florida Solar Energy Center). The DOE also describes a planned field study of installed systems (U.S. Department of Energy). The DOE links suboptimal performance to installation problems (U.S. Department of Energy). National estimates, FSEC research, older airflow measurements and questions for a licensed contractor are all relevant to this question. A contractor, the manufacturer and the equipment manual can each explain what was set up in a particular home. Before any decision about equipment, it helps to read the full DOE and FSEC pages and then ask a licensed contractor how their findings apply to your house.
What federal estimates say about improper installation
Some estimates put most residential HVAC systems among those that were installed improperly and are not performing optimally (U.S. Department of Energy).
The DOE describes these figures as estimates (U.S. Department of Energy).
A separate DOE project describes a planned field study of fault prevalence, meaning how often faults occur, in newly installed systems (U.S. Department of Energy).
What installation faults look like
Suboptimal performance can come from problems such as an incorrect refrigerant charge, too little indoor coil airflow, or an air distribution system that is inefficient (U.S. Department of Energy).
The DOE says testing methods and measurement techniques are needed to judge how serious installation-related faults are in equipment already in service (U.S. Department of Energy).
A licensed contractor can say which checks apply to the equipment in your home and how each one is done. Ask the manufacturer or check the equipment manual for the setup steps that apply to your model.
Why installation quality affects energy use
When systems are installed improperly, they can use more energy than a home needs to stay comfortable (Florida Solar Energy Center).
A contractor can explain what a given measurement means for the equipment in your home.
The FSEC study of newly installed systems
A study funded by the U.S. Department of Energy examined how uniformly heating and cooling equipment is designed and installed under accepted industry practices (Florida Solar Energy Center).
The homes that qualified were single-family detached or attached (townhome) houses in Florida, California, Nevada or Arizona (Florida Solar Energy Center). To qualify, a home needed a central air conditioner or heat pump fitted within the last 12 months (Florida Solar Energy Center). If a utility company had sent the participant a letter, the researchers counted the home as qualifying (Florida Solar Energy Center). Newly built houses were included too (Florida Solar Energy Center).
The study aimed to help the HVAC industry better understand selection and installation of air conditioners and heat pumps under industry standard specifications, and to lower utility bills for homeowners (Florida Solar Energy Center).
Older field tests on air conditioner airflow
The FSEC paper on field tests says air conditioners are generally designed to move "about 400 cfm per ton" across the indoor coil (Florida Solar Energy Center).
The nine field tests described in that paper ran from 1994 to 1998 and were sponsored by various utility companies and research organizations (Florida Solar Energy Center).
Measured external static pressure values for air conditioners in new and existing construction were between two and four times higher than the DOE assumptions (Florida Solar Energy Center). Units in these studies fell short of the design airflow rate, including new townhomes with minimal ductwork (Florida Solar Energy Center).
A utility or the manufacturer can explain what airflow a specific model is designed to deliver.
What the field study will measure
A DOE field study plans to test 50 to 80 newly installed HVAC systems in each of the climate zones cold, marine and mixed-humid (U.S. Department of Energy).
The project is meant to give reliable field data on how often each major fault type occurs and how serious it is (U.S. Department of Energy).
Some of the systems will have long-term monitors to track performance change over the course of the research (U.S. Department of Energy).
Questions to ask a licensed contractor
Ask whether airflow and refrigerant charge were measured after the installation. The DOE lists both among the faults that can lead to suboptimal performance (U.S. Department of Energy).
Ask the contractor to explain each measurement and the result expected for your system.
Keep a written record of the work, including model numbers and measurements, so later service visits have a reference point.
Ask the manufacturer or the equipment manual which setup steps and tolerances apply to your model. Ask your utility whether it offers an efficiency or installation check for your type of system.
Frequently asked
What are installation faults?
Examples the DOE gives include too little indoor coil airflow, an incorrect refrigerant charge and an inefficient air distribution system (U.S. Department of Energy).
Can improper installation waste energy?
FSEC says improperly installed systems can draw more energy than a home requires (Florida Solar Energy Center).
Did the Florida study cover homes like mine?
Homes that counted were single-family detached or attached ones in Florida, California, Nevada or Arizona with a central air conditioner or heat pump fitted within the last 12 months (Florida Solar Energy Center). The study's sign-up page says recruitment for the study has ended (Florida Solar Energy Center). A letter from the participant's utility company also led the team to think the home qualified (Florida Solar Energy Center).
How do I check whether my system was installed well?
Ask a licensed contractor to check airflow and refrigerant charge, which the DOE names among problems that can lead to suboptimal performance (U.S. Department of Energy).
How recent are the airflow field tests?
The nine field tests in the FSEC paper ran from 1994 to 1998, with utility companies and research organizations as sponsors (Florida Solar Energy Center).
Do I need to call a pro for this?
Maybe, depending on how your system was installed. Some estimates cited by the U.S. Department of Energy say most residential HVAC systems are installed improperly (U.S. Department of Energy). The DOE names too little airflow across the indoor coil and an incorrect refrigerant charge among the problems behind suboptimal performance (U.S. Department of Energy). Ask whether airflow and refrigerant charge were measured after the installation. For refrigerant or airflow work, use a licensed contractor.
Related
- What is an economizer in HVAC? How it cools with outdoor air
- Why HVAC maintenance is important for your home
- What Is HVAC? The Parts of a Florida Home's System
Need an HVAC check on the system in your home? Blume Mechanical Service (CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Last updated: 2026-11-21
Sources: U.S. Department of Energy — Optimizing the Installed Performance of Residential HVAC Systems (https://www.energy.gov/cmei/buildings/articles/optimizing-installed-performance-residential-hvac-systems) · U.S. Department of Energy — A Field Study to Characterize Fault Prevalence in Residential Comfort Systems (https://www.energy.gov/cmei/buildings/field-study-characterize-fault-prevalence-residential-comfort-systems) · Florida Solar Energy Center, University of Central Florida — HVAC Quality Installation Study (https://energyresearch.ucf.edu/research-projects/hvac-quality-installation-study/) · Florida Solar Energy Center, University of Central Florida — FSEC-PF-361-01 (https://fsec.ucf.edu/en/publications/html/FSEC-PF-361-01/)
Search Google for how many hvac systems are installed incorrectly