HVAC, explained
Should the Thermostat Fan Be Set to On, Auto or Circulate?
Start with Auto, since Honeywell calls it the normal setting for a system fan (Honeywell 7-day guide). On and Circulate both run the fan while heating and cooling are off, and Trane says the choice between fan settings is a matter of personal preference (Trane XL824).
Honeywell thermostats offer Auto and On, and on select models a third position, Circ or Circulate (Honeywell 7-day guide). Auto runs the fan only when heating or cooling is on. On runs it all the time. Circulate runs it for a set part of each hour, and each brand sets that run time differently (Honeywell fan article; Trane XL824; Sensi).
What each fan setting does
Auto means the fan runs only when the thermostat calls for heating or cooling, and the fan will not blow air unless the system makes a call (Honeywell 7-day guide). Trane says that in Auto mode the circulation time and fan speed options are ignored (Trane XL824). On means the fan is always on, whether or not the heating or cooling is running (Honeywell 7-day guide). Honeywell's FocusPRO P200 manual, for models TH2110U4004 and TH2320U4006, gives the same description for its ON setting (Honeywell FocusPRO P200). Circulate runs the fan a minimum number of minutes each hour, and Trane counts time the system is heating or cooling toward that total (Trane XL824).
How much time Circulate runs the fan
Honeywell's fan operation article says the Circ setting runs the fan randomly about 33 percent of the time (Honeywell fan article). The 7-day guide puts the figure closer to 35 percent, about 20 minutes an hour, with any heating or cooling run time during that hour taken off the total (Honeywell 7-day guide). The FocusPRO P200 manual gives the 33 percent figure for its CIRC setting (Honeywell FocusPRO P200). Sensi thermostats let you choose the run time. Sensi says the setting can be changed in 5 percent steps from 10 percent to 100 percent, and that each percentage stands for minutes per hour (Sensi). Sensi's example says that if the setting is 50 percent, the fan runs 30 minutes every hour (Sensi). Sensi also says that if heating or cooling runs during that hour, that run time is subtracted from the fan's total (Sensi). Trane counts in minutes instead of a percentage, and its Circulation Time is the floor for how long the fan runs each hour (Trane XL824).
When On or Circulate can make sense
Honeywell says the Circ setting is normally used in low-demand periods, such as fall or spring, or during setback such as leave or sleep, to move air around the home (Honeywell 7-day guide). Trane suggests that on a pleasant day the fan can be set to On for a while with the windows open (Trane XL824). Trane also says Circulate mode can clean the air, especially when an air cleaner is installed (Trane XL824). Trane adds an exception for On mode: the fan may not run to keep humidity low when the thermostat is in cooling mode, the system is not in a cooling cycle, and humidity is above the setpoint (Trane XL824).
Why the furnace fan can keep running
Trane's furnace blower guide says the blower typically keeps going for one to five minutes once a heating or cooling run ends, which spreads the air around the home (Trane furnace blower). With the thermostat fan set to On, the blower keeps running while the furnace is not making warm air, so cool air is blown into the home (Trane furnace blower). Trane says to set the thermostat fan to Auto rather than On first (Trane furnace blower). Next it says to check the furnace filter, because a clogged filter can restrict airflow and can also trip a safety switch that shuts the furnace down to prevent overheating (Trane furnace blower). Trane also says to make sure return air vents are not blocked by couches or other furniture (Trane furnace blower). If those checks do not solve the problem, Trane says to call a local HVAC company (Trane furnace blower).
Ceiling fans are a separate fan
The Virginia Tech extension guide covers ceiling fans, which are separate from the thermostat fan (Virginia Tech). Virginia Tech says a running ceiling fan lets you set the cooling thermostat 2 to 4 degrees higher without losing comfort (Virginia Tech). It also says ceiling fans do not reduce humidity, and it pairs them with air conditioning rather than replacing it (Virginia Tech). Using ceiling fans alone is recommended only when relative humidity is under 50 percent (Virginia Tech). It adds that a fan cools people, not rooms, so the guide says to use a fan only while people are in that room (Virginia Tech).
Frequently asked
Do I need to call a pro for this?
No, for changing the fan setting. Honeywell says the FAN button cycles through the available fan modes, and that the modes depend on the system (Honeywell fan article; Honeywell FocusPRO P200). Trane says that if a problem continues, check the thermostat fan setting, the air filter and the return air vents, and if the problem is still there, call a local HVAC company (Trane furnace blower). Trane says a trained HVAC professional handles electrical or wiring issues and blower motor issues (Trane furnace blower), so use a licensed contractor for that work.
What does Circ mean on a Honeywell thermostat?
Circ is the circulate position on a Honeywell thermostat, and Honeywell says it appears on select models only (Honeywell 7-day guide). Honeywell's fan operation article says Circ runs the fan randomly about 33 percent of the time (Honeywell fan article). The 7-day guide gives approximately 35 percent, or roughly 20 minutes an hour (Honeywell 7-day guide).
Why does my furnace fan keep running after the thermostat is off?
Trane says a fan that keeps running can make it seem the fan will not shut off, and that the first thing to check is whether the thermostat fan setting is On rather than Auto (Trane furnace blower). Trane lists electrical trouble at the thermostat, a fan limit switch, a blower motor, or a furnace control board as possible sources of the issue (Trane furnace blower).
Can a fan set to On make the furnace blow cool air?
Yes. Trane says that with the fan set to On, the blower keeps running while the furnace is not making warm air, so the furnace effectively blows cool air (Trane furnace blower).
Can a ceiling fan replace air conditioning?
No. Virginia Tech says ceiling fans do not reduce humidity, and it pairs them with air conditioning rather than replacing it (Virginia Tech).
Related
- Thermostat Settings: Summer, Winter, Fan
- How to Use a Thermostat
- How to program a thermostat: schedules, periods and hold
- Which direction should a ceiling fan turn for cooling, and does a fan lower the temperature?
Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.
Sources: https://www.honeywellhome.com/blogs/support/how-can-i-change-the-fan-operation-setting · https://www.honeywellhome.com/blogs/support/7-day-programmable-thermostats-3 · https://docs.honeywellhome.com/focuspro-p200-um/en-us/Content/User-Manual/Operation%20Settings.htm · https://sensi.copeland.com/en-us/support/circulating-fan · https://support.tranehome.com/hc/en-us/articles/17608851430925-Fan-Settings-on-Trane-XL824-850-1050-Wireless-Thermostats · https://www.trane.com/residential/en/resources/troubleshooting/gas-furnaces/furnace-blower-not-working/ · https://pubs.ext.vt.edu/2901/2901-9002/2901-9002.html