HVAC, explained
What a relay or contactor does in a heating and cooling system
A contactor is the switch in the outdoor unit that decides whether the compressor gets power (Lennox). Signs of failure include a compressor that will not run while the thermostat demand signal is present, a condition where Rheem lists a contactor that has failed open among its possible causes (Rheem), and, if a contactor welds closed, an AC unit that keeps running on constant power (Trane).
A compressor contactor is the switch inside the outdoor unit that decides whether power reaches the compressor (Lennox); Rheem's heat pump document names a time delay relay among the causes of short cycling and mentions a relay in the control area of its 2-speed outdoor fan models (Rheem); and Trane lists a bad relay switch among the causes of an AC that will not turn off (Trane).
What the contactor does
Lennox describes the compressor as the part that moves refrigerant and carries heat between the indoor and outdoor units (Lennox). In the outdoor unit, the contactor is the switch that decides whether the compressor gets power (Lennox). Lennox adds that physical damage or wear can stop it working and cut power to the compressor completely (Lennox).
Signs a contactor has failed
Among the signs Lennox lists for an AC compressor that will not turn on are an outdoor fan that runs with no cool air coming out, and power reaching the unit while the compressor does not engage (Lennox). Lennox names a failed contactor among the most likely culprits (Lennox). On Rheem's heat pump fault table, a red TRIP light with a thermostat call present and the compressor idle lists a contactor that has failed open among its possible causes (Rheem). The same table lists a contactor failed open under a yellow ALERT with flash code 5, labelled Open Circuit, and a contactor failed closed under a yellow ALERT with flash code 8, labelled Welded Contactor, where the compressor always runs (Rheem). Trane says that if a compressor contactor welds closed, the AC unit keeps running on constant power (Trane). Trane also lists a bad relay switch as one of the faults that may keep an AC running all the time (Trane).
Relays and the control circuit on Rheem's heat pump
Rheem says the outdoor unit uses a 24 VAC Class II control circuit (Rheem). Rheem says control circuit wiring must follow the National Electrical Code (ANSI/NFPA 70) and local codes that apply (Rheem). On select models with a two-speed condenser fan motor, Rheem says low cooling runs the motor on low speed and high cooling runs it on high speed (Rheem). Rheem says a relay in the control area moves the fan motor to high speed when the call for high cooling triggers it (Rheem). For short cycling, Rheem lists a defective time delay relay or control board as one listed possibility, under the entry where the compressor runs only briefly (Rheem). Rheem calls the Comfort Alert a monitoring device that gives no safety protection (Rheem). Rheem says a TRIP light usually points to an open compressor protector, and may point to missing supply power to the compressor (Rheem). Rheem defines the red TRIP LED as a thermostat demand signal with no current detected to the compressor (Rheem). Rheem says flash code 9 means the control circuit is below 17 VAC, and that TRIP and ALERT lights flashing together mean the control voltage is too low to run (Rheem).
Fault codes tied to the contactor on Rheem's heat pump
Rheem's TRIP table lists, for a thermostat demand signal with the compressor not running, an open compressor protector, an open compressor circuit breaker or fuse, a broken wire or connector, an open low pressure switch if present, and a compressor contactor that has failed open (Rheem). Under the ALERT entry Open Circuit, flash code 5, Rheem lists the outdoor unit power disconnect, the compressor circuit breaker or fuse, and a contactor that has failed open as listed possibilities (Rheem). For that code Rheem also says to check the contactor wiring and connectors, and to check for contactor failure described as "burned, pitted or open" (Rheem). Rheem says the Comfort Alert module guides the service technician to the root cause of a problem (Rheem). The Welded Contactor entry, flash code 8, lists a contactor that has failed closed and a thermostat demand signal not connected to the module, with the compressor always running (Rheem).
Electrical warnings in Rheem's instructions
Rheem's warning box says, "Ensure all electrical power to the unit is off prior to installing or servicing the equipment," and that failure to do so "may cause personal injury or death" (Rheem). Rheem's wiring warning says to "Turn off all electrical power at the main circuit box before wiring electrical power to the outdoor unit," and that failure to comply "may cause severe personnel injury or death" (Rheem). Rheem's startup and checkout warning says electrical power to the unit must be off before its steps, and that failure to do so "may cause personal injury or death" (Rheem). Rheem's maintenance caution says to be certain power to the outdoor unit and the furnace or air handler is disconnected before recommended maintenance (Rheem). Rheem says a disconnect switch must be in line of sight of the unit and must be able to de-energize it (Rheem). Rheem says its instructions are primarily for qualified individuals experienced in installing heating and air conditioning appliances (Rheem).
When a homeowner should stop and call a technician
Lennox tells owners to call a licensed technician when electrical parts need testing (Lennox). It adds that contactors and wiring call for specialized tools and know-how to diagnose safely (Lennox). Lennox also says a breaker that trips again after a reset signals a deeper electrical problem that calls for professional investigation (Lennox). Trane calls a welded contactor an electrical issue and says a professional needs to replace the faulty switch (Trane). Rheem's caution box on refrigerant charge says, "Under no circumstances," should a homeowner service this equipment. Rheem adds that failure to comply "could result in equipment damage, personal injury, or death" (Rheem).
What Lennox and Trane tell the owner to do
Lennox says to check that the thermostat is on Cool, set below room temperature, with working batteries (Lennox). Lennox says debris around the outdoor unit restricts airflow and can cause overheating (Lennox). Lennox says debris inside the system is for a professional to remove (Lennox). Trane says continuous running of the AC unit or fan may point to a problem that needs investigating (Trane). Trane says an AC that is constantly running can waste electricity and increase the utility bill (Trane). Trane says when the fan setting is on, the blower motor and fan run but the AC unit does not, so the air from the vents is not cool (Trane). Trane gives approximately 20 to 30 minutes as a normal cooling cycle, with two to three cycles each hour (Trane). Trane says it is better to call as soon as the unit is seen running continuously, and warns that waiting may let it burn out and need replacement instead of repair (Trane).
Frequently asked
What is a contactor in an outdoor AC unit?
Lennox says it works as a switch in the outdoor unit that controls power to the compressor (Lennox). Lennox adds that physical damage or wear can stop it working (Lennox).
Why does an AC keep running after a contactor welds shut?
Trane says that if a compressor contactor welds closed, the AC unit keeps running on constant power (Trane). Trane places this under electrical component failures and says a professional needs to replace the faulty switch (Trane).
Should a homeowner replace a contactor?
Lennox tells owners to call a licensed technician when electrical parts need testing (Lennox). Lennox lists a worn contactor among minor issues that are often handled without a full replacement (Lennox). Rheem's caution box says, "Under no circumstances," should a homeowner service this equipment (Rheem).
What does a breaker that keeps tripping mean?
Lennox says repeated breaker trips point to an electrical fault tied to the compressor's power draw (Lennox). Rheem's TRIP table lists an open compressor circuit breaker or fuse among its possibilities when the compressor is not running (Rheem).
Do I need to call a pro for this?
Yes. Contactor and relay work goes to a licensed contractor. When electrical parts need testing, Lennox points owners to a licensed technician (Lennox). Trane treats a welded contactor as an electrical fault that a professional must fix by swapping the bad switch (Trane).
Related
- AC Capacitor and Fan Failures: What the Parts Do and Who Should Replace Them
- AC Won't Turn Off: Why a System Runs Past Its Setpoint
- AC Not Turning On: What to Check Before You Call
- HVAC Blower Motor Repair: What to Check and When to Call
Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.
Sources: Lennox, Why Is My AC Compressor Not Turning On?, https://www.lennox.com/residential/lennox-life/consumer/ac-compressor-not-turning-on · Trane, AC Won't Turn Off? Find Out Why and What to Do, https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ac-wont-turn-off/ · Rheem, Outdoor Heat Pump, Two Stage R-410A Split System, User's Information/Installation Instructions, https://files.rheem.com/LiteratureArchive/7083670.pdf