Evaporator valve in an air conditioner: how it works

A thermostatic expansion valve (TXV) is a small HVAC part that plays a big role in air conditioning systems and heat pump systems (Trane). Carrier says a TXV regulates the flow of refrigerant into the evaporator coil (Carrier). Trane says troubleshooting and maintenance of the TXV or EEV should only be done by a trained HVAC technician (Trane).

The evaporator valve is the part this guide covers. Carrier and Trane both call it a thermostatic expansion valve, or TXV, and both describe it in their own product resources. This guide sets out what those makers say about how the valve works, what it protects and which symptoms point to it. Each statement names the company that said it, so you can see which claim comes from which source.

What the evaporator valve does

A TXV valve (thermostatic expansion valve) is a component in refrigeration and air conditioning systems that regulates the flow of refrigerant into the evaporator coil (Carrier). It automatically adjusts refrigerant flow based on the evaporator's temperature and pressure (Carrier).

Trane says the TXV is located near the indoor evaporator coil (Trane). Trane says an outdoor AC unit has one TXV, but a heat pump may have two, one each for the cooling and heating cycles (Trane).

The next section explains how the sensing bulb tells the valve what to do.

Trane places the TXV near the indoor coil, as described above (Trane).

How the sensing bulb controls flow

Carrier says a TXV has three key components: a sensing bulb, a diaphragm and a needle-and-seat assembly (Carrier). Carrier says the sensing bulb is mounted on the suction line and detects the temperature of refrigerant leaving the evaporator (Carrier).

Trane says there is a sensing bulb connected to the gas line leaving the evaporator (Trane). Trane says the sensing bulb and the TXV form a feedback loop that increases or decreases flow to regulate superheat (Trane).

Trane says the TXV protects the compressor from flooding or overheating (Trane).

The next section covers superheat, which both makers use to describe the valve's job.

Trane describes the same feedback loop as the way the sensing bulb and valve work together (Trane).

Superheat and the evaporator coil

Carrier says the TXV maintains a consistent superheat level, which is the difference between the refrigerant's actual temperature and its boiling point at a given pressure (Carrier).

Carrier says proper superheat keeps the evaporator coil from being overfed or underfed (Carrier).

The signs in the next section are the ones the makers link to valve problems.

Carrier says the feedback loop is what allows the valve to keep superheat steady as conditions change (Carrier).

Signs the valve may be failing

Carrier lists inconsistent cooling, unusual frost buildup on the evaporator coil, fluctuating suction pressure and compressor noise as common signs of a failing TXV (Carrier).

Carrier says excess frost on the evaporator coil often indicates the valve is overfeeding refrigerant (Carrier).

Trane says a failing expansion valve could be to blame if the AC blows hot air, the evaporator coil freezes or temperatures fluctuate (Trane).

Trane says a dirty filter, blocked return ducts, or a refrigerant leak can also cause these problems (Trane).

Trane says a dirty filter, blocked return ducts, or a refrigerant leak can also cause these problems (Trane).

TXV compared with a fixed orifice device

Carrier says a TXV adjusts refrigerant flow dynamically, while a fixed orifice device uses a static opening (Carrier).

Carrier says fixed orifice devices are suited to systems with stable, predictable loads (Carrier).

Carrier says a fixed orifice device uses a static opening that does not change with load (Carrier).

When to call a technician

Trane says troubleshooting and maintenance of the TXV or EEV should only be done by a trained HVAC technician (Trane).

Carrier says that if any of these symptoms appear, a qualified HVAC technician should inspect the valve (Carrier).

Carrier says a malfunctioning TXV can lead to broader system damage if left unaddressed (Carrier).

Carrier says a malfunctioning TXV can lead to broader system damage if left unaddressed (Carrier).

Frequently asked

What is a TXV on an air conditioner?

A thermostatic expansion valve (TXV) is a small HVAC part that plays a big role in air conditioning systems and heat pump systems (Trane). Carrier says a TXV regulates the flow of refrigerant into the evaporator coil (Carrier). Carrier also says the TXV adjusts refrigerant flow based on the evaporator's temperature and pressure (Carrier).

Does a heat pump have one TXV or two?

Trane says an outdoor AC unit has one TXV, but a heat pump may have two, one each for the cooling and heating cycles (Trane). Trane says the TXV is located near the indoor evaporator coil (Trane).

What does frost on the evaporator coil mean?

Carrier says excess frost on the evaporator coil often indicates the valve is overfeeding refrigerant (Carrier). Trane says a failing expansion valve could be to blame if the evaporator coil freezes (Trane). Carrier says a TXV has a sensing bulb, a diaphragm, and a needle-and-seat assembly (Carrier).

Can a homeowner adjust the valve?

Trane says troubleshooting and maintenance of the TXV or EEV should only be done by a trained HVAC technician (Trane). Carrier says a qualified HVAC technician should inspect the valve if any of these symptoms appear (Carrier). Carrier says a malfunctioning TXV can lead to broader system damage if left unaddressed (Carrier).

Is the valve always the cause of poor cooling?

Trane says a dirty filter, blocked return ducts, or a refrigerant leak can also cause these problems (Trane). Carrier says inconsistent cooling is one of the common signs of a failing TXV (Carrier). Carrier says a TXV adjusts refrigerant flow dynamically, while a fixed orifice device uses a static opening (Carrier).

What is superheat?

Carrier says the TXV maintains a consistent superheat level, which is the difference between the refrigerant's actual temperature and its boiling point at a given pressure (Carrier). Carrier says proper superheat keeps the evaporator coil from being overfed or underfed (Carrier). Carrier says if any of these symptoms appear, a qualified HVAC technician should inspect the valve (Carrier).