Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

Why Is My Thermostat Clicking?

Lennox says it is not uncommon for thermostats to click when turning on or off, which is often the relay inside the thermostat switching (Lennox, about its M30). If the click is continuous or very loud, Lennox says it might point to a problem and suggests contacting a professional (Lennox).

Trane lists several possible sources of clicking, including a control board, a loose connection, a safety switch, a capacitor, a contactor and a faulty thermostat (Trane). Trane suggests noting whether clicks come at start-up, at shut-down or during steady running (Trane). Trane also says to note any other heating or cooling problems at the same time (Trane). Trane links a blank digital screen to a thermostat without power (Trane).

What a normal click sounds like

Lennox says it is not uncommon for thermostats to click when they turn on or off, and that the sound is often the relay inside the thermostat switching (Lennox). Lennox makes that statement about its M30 smart Wi-Fi thermostat (Lennox). Trane says normal operation includes humming and the usual startup and shutdown sounds (Trane). Trane also notes that some makers' heat pumps and air conditioners run loudly when starting and stopping, and that kits are available to reduce the noise (Trane).

When a click points to a fault

Lennox says a click that is continuous or very loud might point to a problem, and it suggests a professional for more help (Lennox). Trane lists a failed capacitor as one cause: the unit may click without starting, and an HVAC company is needed for capacitor replacement (Trane). Trane notes a heat pump can use two capacitors, one for starting and one for running, or a single unit that combines them (Trane). The start capacitor gives the compressor and fan motors a short jolt of electricity to help them start (Trane). Outdoors, Trane links clicking to a capacitor or a contactor (Trane). At the indoor unit, Trane lists a control board fault, a loose wire connection or a safety switch as possible causes (Trane). Trane also connects clicking to a faulty thermostat (Trane). Trane says a noticeably louder unit often signals a capacitor or compressor concern (Trane). Trane says loud, odd HVAC noises generally mean a repair call is needed (Trane).

Can a low battery affect heating?

On a heat pump, Trane says that when the digital screen is blank, the thermostat can be without power and cannot signal the electric heat pump to turn on (Trane). Trane also says dead batteries are the most likely reason a thermostat will not turn on (Trane). It adds that if changing the batteries does not help, the home's main power may be at fault (Trane). Honeywell's T6 Pro manual says the backlight is disabled at low battery, and that at critically low battery the Home screen shows just the BATT indicator with its icons (Honeywell). Honeywell says the batteries must be replaced when BATT shows on the Home screen with the alert and battery icons (Honeywell). For CT3200, CT3300, T8112 and T8132 thermostats, Honeywell says that if the LOW BAT message is still showing after a battery change, alkaline batteries are the type to use (Honeywell). Honeywell warns that rechargeable or lithium cells will not work properly in those models (Honeywell).

Checks a homeowner can make

Trane's heat pump page says to confirm the thermostat is set to Heat or Cool, and says wrong thermostat settings are a frequent cause of a system that will not start (Trane). It says a dirty filter or a blockage at the outdoor unit can make a heat pump overheat and shut down, so check the filter and change it if dirty (Trane). Trane says furniture or curtains should not block the return air vents (Trane). Trane asks for one to two feet of open space around the outdoor unit and says to clear leaves, twigs or snow from the top (Trane). On filter timing, Trane's heat pump page gives 1-3 months as the interval (Trane), and Trane's smells article gives 30-90 days (Trane).

Safety limits

Trane says "Homeowners should never try to troubleshoot electrical issues or repair a faulty HVAC system part on their own" (Trane). On the heat pump page, Trane says a tripped breaker for the heat pump means calling for HVAC service, since the unit may have a problem that tripped it (Trane). Trane warns that resetting the breaker and restarting could do more damage (Trane). The Trane smells article says such issues can involve electrical parts, gas or refrigerant, and that handling them wrongly can create safety hazards (Trane). Electrical and refrigerant work belongs to a licensed contractor.

Frequently asked

Do I need to call a pro for this?

Maybe. Lennox says a click that is continuous or very loud might point to a problem and suggests a professional (Lennox). Trane says loud, odd HVAC noises generally mean a repair call is needed (Trane). The checks you can make yourself are the thermostat setting, the air filter, the return vents and the outdoor clearance. Electrical work belongs to a licensed contractor.

Can a low battery stop the heat from coming on?

Maybe, on a heat pump. Trane says that when the digital screen is blank, the thermostat can be without power and cannot signal the electric heat pump to turn on (Trane). Trane also says dead batteries are the most likely reason a thermostat will not turn on (Trane).

Does a Honeywell T6 Pro show a low battery warning?

Yes. The T6 Pro shows an alert icon on the Home screen, and BATT appears there for the low battery alert (Honeywell). The manual says the backlight is disabled when battery power is low (Honeywell).

Can a failed capacitor make a heat pump click?

Trane says a failed capacitor can leave the heat pump making a clicking sound without starting (Trane). Trane says an HVAC company is needed for capacitor replacement (Trane).

Is a click at startup or shutdown normal?

Lennox says a click when a thermostat turns on or off is often the relay switching (Lennox). Trane says the more detail you give a technician about when the click happens, the better (Trane).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: https://www.honeywellhome.com/blogs/support/how-do-i-delete-the-low-bat-message-displayed-on-my-ct3200-ct3300-t8112-t8132-thermostat-screen · https://docs.honeywellhome.com/t6-pro-ii/en-us/Content/Installation-Instructions/7.%20Alerts%20and%20Reminders.htm · https://www.lennox.com/residential/support/faqs/is-the-m30-thermostat-supposed-to-make-a-clicking-sound · https://www.trane.com/residential/en/resources/troubleshooting/thermostat-controls/ · https://www.trane.com/residential/en/resources/troubleshooting/heat-pumps/heat-pump-not-turning-on/ · https://www.trane.com/residential/en/resources/blog/hvac-smells-and-noises-explained/

Search Google for why is my thermostat clicking