Central AC running but not blowing air

When a central AC runs but no air comes from the vents, the indoor blower may be the cause, because Trane says that if the outdoor condenser fan is running normally, a blower motor problem is more likely, especially when there is low or no airflow from the vents (Trane). A homeowner can check the thermostat fan setting, the air filter, the vents and return grilles, and the outdoor unit, while Lennox says a very dirty or misplaced filter can restrict airflow so much that the fan keeps running with no cool air at the vents (Lennox).

A central air system has two fans and two coils: an outdoor condenser fan and an indoor blower that pushes air through the ducts (Trane). Trane says the indoor air handler holds both the evaporator coil and the blower motor with its blower fan (Trane), so a fault inside the house can leave the vents quiet while the outdoor unit runs. Trane says restricted airflow is the biggest reason for frozen coils (Trane), and Carrier says that a frozen coil will not fix itself (Carrier). The checks below are the ones a homeowner can make safely. Refrigerant, electrical, and capacitor work belongs to a licensed contractor.

When the outdoor unit runs but the indoor blower does not

Trane says the first step is to tell whether the problem sits with the condenser fan outside or the blower motor inside, and that the condenser fan can be seen from the top of the unit (Trane). If the outdoor fan is running normally and airflow from the vents is low or missing, Trane says the blower motor may be the problem (Trane). Trane lists the reasons an indoor air handler may not turn on at all: no power to the unit, a clogged filter, a frozen evaporator coil, a bad blower motor capacitor, a failed blower motor, and a control board problem (Trane). Trane says a bad capacitor stops the blower motor from running, so the fan will not move conditioned air through the home, and that a technician needs to troubleshoot it (Trane).

Check the thermostat fan setting first

Carrier says to check that the thermostat is set to cool, and to switch it back to cooling if it has been set to heat or to a constant fan setting labeled on (Carrier). Trane advises setting the fan to AUTO. With the fan on ON, Trane says the system pushes warm, unconditioned air even while the AC is off (Trane). Trane also says the set temperature should be lower than the current indoor temperature, and that a programmable schedule should not be set to stop the AC from running (Trane). Lennox says dead thermostat batteries, or batteries installed incorrectly, can cause thermostat trouble (Lennox). After the system starts, Carrier says to wait a few minutes and then check the registers for cold air (Carrier).

Check the air filter, vents and return grilles

Carrier says the filter catches dirt and particles, and that a clogged filter blocks airflow and can make the system shut down (Carrier). Carrier says that if the thermostat checks out but the air still is not cold, the system should be switched off and the filter inspected (Carrier). Filter change intervals differ by source: Carrier recommends changing filters every 60 to 90 days (Carrier), Lennox says every three months (Lennox), and Trane says generally every one to three months (Trane). Lennox says vents must remain wide open for the air conditioner to work properly (Lennox). Trane says to keep registers and return air vents clear (Trane). Lennox adds that uneven cooling between rooms can mean cool air is escaping into the attic (Lennox).

A frozen evaporator coil: what to do and what to avoid

Carrier says frost on the copper tubing, inadequate cooling, or excessive condensate drainage can mean the evaporator coil is frozen (Carrier). Trane names ice on the coil or its cabinet, frozen lines at the outdoor unit, and water pooling on the floor as warning signs (Trane). Trane says the safest step is to switch the thermostat from COOL to OFF and call for service, and says not to chip away at the ice because that can damage the coil (Trane). Carrier says never to use heat sources such as hairdryers or space heaters, because the heat can cause thermal shock and crack components (Carrier). Carrier also says not to pour hot water on frozen coils, since rapid temperature change can crack or warp the metal (Carrier). Carrier warns against running the system with frozen coils, since that cuts off airflow and makes the compressor work harder (Carrier). Carrier notes that light frost may clear in roughly 1 to 3 hours, while heavy ice can need 4 to 8 hours or longer (Carrier). A Carrier FAQ says coils typically thaw within 1 to 4 hours (Carrier).

Outdoor unit, drain pan and safety switch

Carrier says dirt, grass and debris can clog the outdoor coil fins, and that the coil can be cleaned by clearing debris and gently rinsing it with a hose (Carrier). Trane says to clear away tall grass, sticks or leaves around the outdoor unit (Trane). Lennox says to clean the outdoor unit of debris once a month (Lennox). Trane says to keep plants at least two feet from the sides of the outdoor unit (Trane). Trane notes that some indoor units use a condensate safety switch in the drain pan that shuts the unit down when water rises in the pan (Trane). Trane also says a clogged condensate drain line can cause a blockage, and that fixing it is work for a trained technician (Trane).

Electrical and capacitor problems go to a licensed contractor

Trane says to look at the breaker panel to see whether the AC breaker has tripped, and to call a local Trane expert if no power is reaching the unit (Trane). Trane says that if the breaker has tripped, the next step is to call for HVAC repair rather than turning the system back on before the problem is resolved (Trane). Lennox says a single breaker trip now and then is not unusual, but repeated trips point to bigger electrical issues that call for a qualified professional (Lennox). Trane says the run capacitor is a metal cylinder that starts and runs the motor, that a faulty one can leave the system unable to start or blowing no cold air, and says not to replace it yourself (Trane). Trane cautions that restarting the system before the fault is fixed may damage it (Trane). If a broken outdoor fan blade is found, Trane says to keep the system off and call a local expert (Trane).

Burning smells, leaks and blower motor wear

Lennox lists reduced airflow, unusual noises, high energy bills, a burning smell from the vents, and a tripped breaker as signs of a failing blower motor, and says not to ignore the problem (Lennox). Lennox says the blower motor can break down early because of dirt buildup, electrical issues or overuse (Lennox). Trane says that if an air conditioner smells burning or moldy, the system should be turned off and an HVAC professional contacted immediately (Trane). Lennox says a refrigerant leak may make a hissing noise, and that if you think there is a leak, turn off the AC and call a professional, because refrigerant leaks can be toxic (Lennox). Carrier says that if you suspect a leak, you should not attempt to fix it yourself (Carrier). Trane says low refrigerant can come from a leak or from an improper charge at installation, so a professional must assess and fix it (Trane).

Undersized systems and refrigerant questions

Carrier says an undersized unit will struggle (Carrier). Carrier says a qualified HVAC professional can assess the optimum cooling capacity of the home (Carrier). Trane says air conditioners are sized by the cooling they provide in BTUs, and that a professional can assess sizing, with adding ductless units as one option in some cases (Trane). Trane says a refrigerant leak is work for a professional technician (Trane).

Frequently asked

Do I need to call a pro for this?

Yes, call a licensed contractor if the indoor blower does not run, a breaker keeps tripping, the coil freezes again after thawing, or you smell something burning. Lennox says repeated breaker trips need a qualified professional, Trane says a burning or moldy smell means turning the system off and contacting a professional immediately, and Carrier says a coil that freezes again points to an underlying issue that needs a professional (Lennox; Trane; Carrier).

Should I turn off my AC if the coil is frozen?

Yes. Carrier says to turn the AC off right away so the ice can thaw, and Trane says to switch the thermostat from COOL to OFF and call for service (Carrier; Trane).

How long does a frozen AC coil take to thaw?

Carrier notes that light frost may clear in roughly 1 to 3 hours, while heavy ice can need 4 to 8 hours or longer (Carrier). A Carrier FAQ says coils typically thaw within 1 to 4 hours (Carrier).

Can I run the AC while the coil is frozen?

No. Carrier says never to run an AC with frozen coils, because the blocked airflow forces the compressor to work harder (Carrier).

Why does my AC blow warm air when the fan is on?

Trane says that with the fan set to ON, the system blows warm, unconditioned air even when the AC is not running, so the fan should be set to AUTO (Trane).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: Carrier, Why Is My AC Not Blowing Cold Air?, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/ac-not-blowing-cold-air/ · Carrier, Will Frozen AC Fix Itself?, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/will-frozen-ac-fix-itself/ · Lennox, What to do when your AC is not blowing cold air, https://www.lennox.com/residential/lennox-life/consumer/ac-not-blowing-cold-air · Lennox, What is an HVAC Blower Motor, https://www.lennox.com/residential/lennox-life/consumer/hvac-blower-motor · Trane, AC Fan Not Working?, https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ac-fan-not-working/ · Trane, Air Conditioner Troubleshooting: 5 Common Issues, https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ · Trane, Air Handler Freezing Up: Causes and Solutions, https://www.trane.com/residential/en/resources/troubleshooting/air-handlers/air-handler-freezing-up/ · Trane, Air Handler Not Working But Outside Unit Is, https://www.trane.com/residential/en/resources/troubleshooting/air-handlers/air-handler-not-working-but-outside-unit-is/ · Trane, AC Not Blowing Cold Air?, https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ac-not-blowing-cold-air/