HVAC, explained
Refrigerant types explained: R-22, R-410A, R-32, R-454B
EPA says HFC substitutes have zero ozone depletion potential because they contain no chlorine (EPA). EPA says you can continue to service an existing HCFC-22 system, and it does not require homeowners to replace existing equipment (EPA). EPA says HFCs are potent greenhouse gases (EPA). Check the refrigerant name on your unit's nameplate before you call a technician.
Air conditioners and heat pumps use refrigerants with names such as R-22, R-410A, R-32 and R-454B. Refrigerant names matter for the ozone layer, for the climate and for the rules that apply when a unit is serviced or sold. The sections below start with the chemical families, move to the federal rules, then to the specific refrigerant names, and end with a checklist for your own equipment. Check the nameplate and manual for the refrigerant your unit actually uses before you plan any work.
Three refrigerant families: CFCs, HCFCs and HFCs
CFCs are organic compounds made of carbon, chlorine and fluorine atoms (EPA). HCFCs are compounds that contain hydrogen, fluorine, chlorine and carbon atoms (EPA). HFC substitutes are a different group, and EPA says they contain no chlorine (EPA).
If a refrigerant name on your unit's label is unfamiliar, ask the manufacturer or a licensed contractor which family it belongs to. Write the model and serial numbers down before the call, so the answer applies to your exact equipment.
When you call a contractor about a refrigerant question, have the model number, serial number and a photo of the nameplate ready. Note any past repairs and the install year, if you know it. Clear details help the technician answer for your specific unit.
Ozone depletion and how HCFCs compare with CFCs
EPA says HCFCs are ozone depleting but less potent at destroying stratospheric ozone than CFCs (EPA).
EPA says certain human-made chemicals containing chlorine and bromine can cause the depletion of stratospheric ozone (EPA).
EPA says ozone-depleting substances in the United States are regulated as Class I or Class II controlled substances (EPA). Ask a licensed contractor which class applies to the refrigerant in your unit, and keep that answer with the equipment records. Keeping it there makes the answer easy to find at the next service visit.
What the rules mean for an HCFC-22 system
EPA says you can no longer purchase a central AC unit that uses HCFC-22 (EPA). That statement is about central AC units (EPA).
EPA says there is no EPA requirement to convert existing HCFC-22 units to a non-ozone-depleting substitute refrigerant (EPA). Any conversion decision is one to discuss with a licensed contractor who can see the equipment.
Servicing an existing R-22 system
EPA says you can continue to service your existing HCFC-22 system (EPA). If your unit is an older HCFC-22 system, ask your contractor to explain the repair options for that exact unit.
EPA tells homeowners to confirm that a technician has the EPA Section 608 qualification needed for equipment containing HCFC-22 (EPA). Ask the technician to show that qualification before work begins. Ask whether the technician will check the unit before any refrigerant is added, and ask for the repair plan in writing before you agree to it.
EPA reports that refrigerant reclaimers reclaimed more than 140 million pounds of HCFC-22 from 2000 to 2018 (EPA). That figure is past volume, not a forecast of future supply.
EPA says refrigerants sold as "22a" or "R-22a" have never been submitted to EPA for review of their health and environmental impacts (EPA). Ask the technician to name the refrigerant on the invoice before any charge is added, and do not accept a product sold under those names without a written answer.
HFCs and climate impact
EPA says HFCs are potent greenhouse gases whose GWPs can be hundreds to thousands of times higher than carbon dioxide (EPA). These figures describe HFCs as a group. Ask the manufacturer for the GWP of the refrigerant in your unit before you compare it with another model.
EPA says it is phasing down regulated HFCs to 15 percent of their historic baseline levels by 2036 (EPA). EPA says the phasedown schedule started with a 10 percent reduction in 2022 and a further decrease in 2024 to 60 percent of baseline levels (EPA). These steps describe supply limits, not retail prices.
EPA says the American Innovation and Manufacturing Act of 2020 (AIM Act) was enacted on December 27, 2020 (EPA). EPA also says the United States ratified the Kigali Amendment on October 31, 2022 (EPA).
What the phasedown means for equipment you already own
EPA says consumers can keep using their equipment until the end of its useful life (EPA). EPA says there are no requirements to stop using any specific equipment or appliance currently in use (EPA).
EPA says the 2023 Technology Transitions Rule does not limit the use of any existing product or system (EPA). EPA also says the rule is forward looking and restricts new products and systems from being placed on the market or entering operation (EPA).
Those existing-equipment statements do not cover equipment bought or installed in future years, so ask your contractor which rules apply to a new purchase.
R-410A and EPA stand-alone equipment listings
EPA lists R-410A as unacceptable in retrofit equipment as of July 20, 2016 (EPA). EPA lists R-410A as unacceptable in new stand-alone low-temperature units as of January 1, 2020 (EPA).
Those listings come from EPA's stand-alone equipment page (EPA). If your system is a residential central or split unit, read its manual and ask the manufacturer what refrigerant it is designed to use.
Keep a copy of the nameplate and the manual with your home papers, and give a copy to any new technician. If the unit has been changed in the past, note that change on the same copy.
R-32 and R-454B on the ENERGY STAR heat pump specification
ENERGY STAR's heat pump specification lists R-32, R-410A and R-454B as refrigerant options, without explanation (ENERGY STAR). ENERGY STAR says listed refrigerants should use the nomenclature in the EPA SNAP approved list (ENERGY STAR).
EPA says that if an air conditioner contains alternative refrigerants, the service technician should be trained in their use (EPA). Ask the technician whether that training covers the refrigerant in your unit.
For handling, safety or class questions about R-32 or R-454B, ask the manufacturer and a licensed contractor. Keep the refrigerant name from the model's label on file with your equipment records. Bring a nameplate photo to the appointment, so the technician can confirm the refrigerant name before ordering any parts.
Ozone-friendly refrigerants and what to check first
EPA says a number of ozone-friendly refrigerants are available and widely used today (EPA). EPA does not require homeowners to replace their existing equipment (EPA).
Read the refrigerant name on the nameplate, then match it to the manufacturer's manual. Call a licensed contractor before any refrigerant work, and ask for the refrigerant name in writing on the invoice. A written record of the refrigerant type, the service date and any amount added or recovered makes later questions easier to answer. Blume Mechanical Service repairs, installs and maintains HVAC and refrigeration equipment, and it is brand-agnostic.
Frequently asked
Does my R-22 system have to be replaced?
EPA does not require homeowners to replace their existing equipment (EPA). EPA says you can continue to service your existing HCFC-22 system (EPA). Replacement timing is a decision to make with a licensed contractor.
Can I still buy a new central AC that uses HCFC-22?
No. EPA says you can no longer purchase a central AC unit that uses HCFC-22 (EPA). That statement is about central AC units (EPA).
Who should service an HCFC-22 system?
EPA tells homeowners to confirm that a technician has the EPA Section 608 qualification needed for equipment containing HCFC-22 (EPA). Ask to see that qualification before the work begins.
What does EPA list for R-410A in stand-alone equipment?
EPA lists R-410A as unacceptable in new stand-alone low-temperature units as of January 1, 2020 (EPA). It also lists R-410A as unacceptable in retrofit equipment as of July 20, 2016 (EPA). Both listings come from EPA's stand-alone equipment page (EPA).
Do R-32 and R-454B appear in ENERGY STAR's heat pump specification?
ENERGY STAR lists both as refrigerant options in its heat pump specification, without explanation (ENERGY STAR). Ask the manufacturer and a licensed contractor about the handling and class rules for your unit's refrigerant.
Are there ozone-friendly refrigerants?
Yes. EPA says a number of ozone-friendly refrigerants are available and widely used today (EPA). Read the nameplate to find out which one your unit uses.
Do the HFC phasedown rules force me to stop using my equipment?
No. EPA says consumers can keep using their equipment until the end of its useful life (EPA). EPA also says there are no requirements to stop using any specific equipment or appliance currently in use (EPA).
Can I keep repairing my existing system?
EPA says yes, a homeowner can continue to repair an existing refrigeration, air conditioning, or heat pump system (EPA). EPA also says replacement components, regardless of manufacture date, can be used for maintenance (EPA). Ask your contractor whether a repair needs a new refrigerant charge.
Related
- When air conditioning became common in U.S. homes
- Low-e coatings and window film for homes
- A2L refrigerants: what homeowners should know
Need refrigerant or HVAC service? Blume Mechanical Service (CAC-1822618) serves Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: EPA — Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps (https://www.epa.gov/snap/substitutes-residential-and-light-commercial-air-conditioning-and-heat-pumps) · EPA — Homeowners and Consumers: Frequently Asked Questions (https://www.epa.gov/ods-phaseout/homeowners-and-consumers-frequently-asked-questions) · EPA — Substitutes in Stand-alone Equipment (https://www.epa.gov/snap/substitutes-stand-alone-equipment) · EPA — Basic Ozone Layer Science (https://www.epa.gov/ozone-layer-protection/basic-ozone-layer-science) · EPA — Information on Ozone and Ozone Depletion (https://www.epa.gov/ozone-layer-protection/information-ozone-and-ozone-depletion) · EPA — Frequent Questions on the Phasedown of Hydrofluorocarbons (https://www.epa.gov/hfcs/frequent-questions-phasedown-hydrofluorocarbons) · EPA — Phaseout of ODS Under the Clean Air Act (https://www.epa.gov/ods-phaseout/phaseout-ods-under-clean-air-act) · EPA — Resources for Stationary Refrigeration and Air-Conditioning Equipment Technicians (https://www.epa.gov/section608/resources-stationary-refrigeration-and-air-conditioning-equipment-technicians) · ENERGY STAR — Product specification for heat pumps, spec/145 (https://www.energystar.gov/products-plato/spec/145)