What R-407C refrigerant is and what R-22 system owners should know

R-407C is a hydrofluorocarbon (HFC) blend that Chemours makes under the Freon 407C brand (Chemours). Chemours offers it as a substitute for R-22 in positive displacement AC equipment, and EPA says owners of HCFC-22 air conditioners may keep using them and are not required to replace them (Chemours; EPA). EPA's SNAP list also names R-407C as an acceptable substitute for HCFC-22, the refrigerant also called R-22 (EPA SNAP list; EPA).

EPA says owners can keep running window or central air conditioners that use HCFC-22 (EPA).

What R-407C is

Chemours says the Freon 407C blend is used in commercial and light commercial air conditioners fitted with air-cooled direct expansion chillers (Chemours). Chemours also says the blend can suit many medium-temperature refrigeration systems that once ran on R-22 (Chemours). The maker gives the parts in the blend as HFC-32, HFC-125 and HFC-134a (Chemours).

What it replaces

Chemours says R-407C can take the place of R-502 at medium temperatures, in new and existing equipment, where evaporator temperatures stay above 20 °F (-6.7 °C) (Chemours). EPA's SNAP list also names R-407C as an acceptable substitute for HCFC-22, in a notice dated February 8, 1996 (EPA SNAP list). EPA says the word "Freon" is a trademark used for several refrigerants, among them HCFC-22, which is often called R-22 (EPA).

How the maker compares it with R-22

Chemours says R-407C behaves very much like R-22 in operation, though new systems may get slightly modified components (Chemours). The Chemours table lists, against R-22, a discharge pressure change of +15 to +25 psi and a discharge temperature change of -10 to -15 °F (Chemours). A second Chemours document, the retrofit guidelines, gives a different range for cooling mode: +15 to +40 psi in discharge pressure and -15 to -8 °F in discharge temperature (Chemours retrofit guidelines). Chemours says energy efficiency depends on equipment design, and that it will be very similar to R-22's (Chemours).

Lubricant and service tools

Chemours recommends a polyol ester (POE) lubricant of high quality, and says to consult the compressor or system OEM (Chemours). Chemours says existing service tools can be used, but that care is needed to avoid mixing different refrigerants and lubricants (Chemours).

Retrofitting an R-22 system

Chemours says air-conditioning units now running on R-22 can be retrofit to R-407C, and that the OEM should be consulted for guidelines (Chemours). Chemours says that, when its retrofit guidelines are followed, many R-22 systems can be adapted to keep running safely and efficiently once R-22 is no longer available (Chemours retrofit guidelines). Chemours says Freon 407C is commercially available for retrofitting existing equipment and as a long-term choice to replace R-22 in new equipment (Chemours retrofit guidelines). Chemours's guidelines are addressed to service contractors doing first retrofits, and recommend collecting baseline data while the system still holds R-22 (Chemours retrofit guidelines).

Seals and the technician's role

Chemours recommends checking gaskets, shaft seals and O-rings with the equipment manufacturer before a retrofit (Chemours retrofit guidelines). Chemours says some systems switched straight from CFC or HCFC to an HFC refrigerant have shown more elastomer leakage, and that if a poor seal results, the used O-rings should be replaced with new ones of the same material (Chemours retrofit guidelines). EPA says it matters that a technician holding Section 608 credentials recovers leftover HCFC-22 before a non-ozone-depleting alternative goes in (EPA). EPA's wording also covers explaining how the conversion may affect performance and energy use (EPA).

What EPA says about retrofits

EPA says there is no requirement to convert existing HCFC-22 units, and that a retrofit is allowed if the alternative is accepted under EPA's SNAP program as suitable for that type of use (EPA). EPA also says there are no "drop in" replacements for HCFC-22, and that alternative refrigerants do not work well without changes to system components (EPA).

Leaks and topping off

EPA says homeowners should ask service technicians to find and fix leaks rather than top off a leaking system (EPA). Chemours says R-407C can be topped up after a leak more than once, with minimal impact on system performance (Chemours). EPA calls proper maintenance the most important step, because good servicing reduces environmental damage and lengthens how long a system lasts (EPA). EPA says serious leaks seldom form in units that were installed correctly and are maintained on a regular schedule (EPA).

Who may service the system

EPA says refrigerant for stationary appliances is sold only to Section 608 technicians and to the firms that employ them (EPA). EPA says it is illegal to intentionally release any refrigerant during maintenance, service, repair or disposal of AC equipment (EPA). EPA says Section 608 of the Clean Air Act prohibits knowingly venting HCFC-22 and its substitutes, including HFCs, during maintenance, service, repair or disposal of AC and refrigeration equipment (EPA). EPA says to make sure the technician has the required Section 608 certification (EPA).

Finding out what your system uses

EPA says a home AC's refrigerant is typically shown on its nameplate. For central units, it is most often found on the outdoor condenser (EPA). If there is no nameplate, EPA says to check the owner's manual or contact the company that sold or services the unit (EPA). EPA says that as of January 1, 2020, "no new HCFC-22 will be made or imported" into the United States, and that used HCFC-22 cleaned up to the same standards as new refrigerant will keep being available (EPA). EPA also says recovered and reclaimed HCFC-22, along with HCFC-22 made before 2020, will help meet the needs of those who keep existing HCFC-22 systems running well beyond the phaseout date (EPA).

Disposal

EPA says: "Do not tamper with an appliance before it is disposed of," such as by cutting refrigerant lines or removing compressors (EPA).

Frequently asked

Can I keep running an R-22 air conditioner?

Yes. EPA says HCFC-22 air conditioner owners may keep using them and need not replace them (EPA). EPA says there is no requirement to convert existing HCFC-22 units (EPA).

Is R-407C a drop-in replacement for R-22?

No. EPA says HCFC-22 has no drop-in substitute (EPA). Alternatives, EPA adds, perform poorly unless system components are changed (EPA).

Can I top off a leaking R-407C system myself?

No. EPA advises homeowners to have a technician find and fix a leak instead of topping off the system (EPA). EPA says serious leaks seldom develop in units that were installed correctly and kept up on a regular maintenance schedule (EPA).

Do I need to call a pro for this?

Yes. Refrigerant work goes to a licensed contractor. EPA says it is against the law to release refrigerant on purpose during AC maintenance, service, repair or disposal (EPA). EPA notes that stationary-appliance refrigerant is sold only to Section 608 technicians and the firms employing them (EPA).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: Chemours, Freon 407C Refrigerant (R-407C) Frequently Asked Questions, https://www.chemours.com/en/-/media/files/freon/freon-407c-faq.pdf?rev=b9ddb6a9c399447c9ecc60fa57228f82 · Chemours, Freon 407C Retrofit Guidelines, https://www.chemours.com/en/-/media/files/freon/freon-407c-retrofit-guidelines.pdf?rev=f1da259ca7d04d9883e846e750f08003 · EPA, Homeowners and Consumers: Frequently Asked Questions, https://www.epa.gov/ods-phaseout/homeowners-and-consumers-frequently-asked-questions · EPA, Regulations, Proposed Rules and Final Rules Determined by EPA (SNAP), https://www.epa.gov/snap/regulations-proposed-rules-and-final-rules-determined-epa