HVAC, explained
Is dehumidifier water distilled or safe to use?
Check your dehumidifier's manual before using the water in its bucket for drinking, pets or plants. EPA describes condensate from air conditioners as essentially distilled water, a statement about AC systems rather than dehumidifier buckets (EPA). ENERGY STAR advises keeping drain hoses away from electrical cords and connections (ENERGY STAR).
Anyone who empties a dehumidifier bucket can wonder what the water is and where it should go. The sections below cover what EPA, ENERGY STAR and the Florida Solar Energy Center (FSEC) say about that water, drains, shutoffs and mold, and what to check on your own unit. Read each section for its scope, since some findings come from air conditioners or commercial generators. This information does not replace the manufacturer's manual or advice from a licensed technician. The sections below move from the water itself to the drain, the shutoff and the mold risk, and end with the questions to ask before you use the water.
How atmospheric water generators collect water
EPA says the most commonly used atmospheric water generators pull moisture from the air with a condenser and cooling coil (EPA). EPA describes that process as the same way a household dehumidifier does (EPA).
Atmospheric water generators are a separate subject from dehumidifiers. The collection method alone does not describe how the water is treated. Do not treat the two products as the same.
When you read any study, look first at what it tested. A result for one product describes that product and its setup, so check it before applying it to a different appliance.
What EPA found for one tested generator
EPA reported that all test results for one commercial generator indicated its water was microbiologically safe for human consumption (EPA). The unit in that study was the Watergen GEN-350, a commercial atmospheric water generator (EPA). That result covers one commercial unit in the study, not household dehumidifiers.
Keep a note of the source name, page title and date for any test result you rely on, so you can show exactly what it covers.
EPA also found high heterotrophic plate count results in both treated and untreated water from that unit (EPA). HPC counts the bacteria that grow in water, so it is a count, not a yes or no on drinking safety.
Other bacteria results from the same study
The maker of that tested unit acknowledged the need for further disinfection to reduce the risk of microbial growth (EPA). Weekly samples from the unit did not detect Legionella or Mycobacteria (EPA).
Indicators of fecal contamination, such as fecal coliforms and Escherichia coli, were not detected in that unit (EPA). These results describe one commercial unit and are not a test of dehumidifier water.
CDC says some germs can grow in a slime layer inside water pipes or in devices that use water, such as humidifiers (CDC). CDC says these germs generally will not make you sick if you swallow them, but they can make you sick if they get in your body another way (CDC). That statement covers germs in water-using devices, and CDC does not say the water is safe to drink (CDC).
CDC gives breathing in mist while showering, or getting germs up your nose while rinsing your sinuses, as examples of how these germs can make people sick (CDC). Germs can also grow in filters and other treatment systems if they are not maintained properly (CDC).
When you call a manufacturer, ask three questions: whether its water is intended for drinking, whether the bucket can be used for other purposes, and how the bucket should be cleaned.
What the HVAC condensate study says
An EPA abstract on reusing HVAC condensate describes humidity in the air that forms condensation as essentially distilled water (EPA). That clause describes air-conditioner condensate in a study of water reuse, not a drinking-water rule (EPA).
Do not apply that description to a dehumidifier bucket without first checking the unit's manual.
FSEC says condensate in an air-conditioner pan slowly evaporates during long compressor off-cycles (FSEC). That shows condensate can return to the air, but it does not show whether the water is safe to drink (FSEC).
The same care applies to any study that describes a different kind of system from yours, even when it uses the word distilled.
Drain placement and electrical safety
ENERGY STAR says never to set up water drainage or disposal near electrical circuits or devices (ENERGY STAR). It also advises keeping drain hoses away from electrical cords and connections (ENERGY STAR).
Make sure the dehumidifier is connected to a properly grounded outlet (ENERGY STAR). These are electrical and placement rules, and they do not describe the quality of the water (ENERGY STAR).
FSEC says to make sure coils are clean, the condensate drains properly and the drain pan has no mold, as part of an air-conditioner check (FSEC).
Placement is simple to check. Look at where the drain hose ends, what sits beneath it, and whether a cord runs across the floor near the unit.
Shutoffs, humidity and mold
For portable units with a removable bucket, there is typically an automatic shutoff when the bucket is full (ENERGY STAR). That shutoff prevents overflow, and it does not address the water inside the bucket.
ENERGY STAR says the dehumidifier size, or capacity, is usually measured in pints per 24 hours (ENERGY STAR). If you are replacing an existing dehumidifier, ENERGY STAR says you can judge by how much water you empty each day (ENERGY STAR).
ENERGY STAR also says that indoor humidity above the optimum range may promote mold growth (ENERGY STAR). Compare room readings with the optimum humidity range. ENERGY STAR says humidity is most often talked about in terms of Relative Humidity (RH) (ENERGY STAR). EPA says hygrometers, available at local hardware stores, may be used to measure humidity levels (EPA), and that higher humidity levels may encourage the growth of biological organisms in the home (EPA).
Keep the unit where you can see its bucket and indicator.
Drying wet items and watching for leaks
EPA says that in most cases mold will not grow if wet or damp items are dried within 24 to 48 hours (EPA). That guidance covers wet building materials and items, not water held in an appliance (EPA).
The Florida Solar Energy Center says even small water leaks will cause mold problems (FSEC). After each emptying, check the bucket, the hose and the drain connection for drips.
If a leak or a damp area returns, the manual and a licensed technician are the next steps to take.
Where to drain it and what to check
FSEC advises that draining condensate from a dehumidifier to a sink is often the suggested method (FSEC). That is a drain method for Florida homes, not a statement about whether the water is safe to drink or use on plants (FSEC).
Check the manufacturer's manual for the unit's rules on collected water, cleaning and drainage. If you cannot find the manual, locate the model number on the unit's nameplate and contact the manufacturer directly.
Blume Mechanical Service repairs, installs and maintains HVAC and refrigeration equipment.
Minerals, bottled water and distillation
EPA's guidance on home humidifiers says distillation is the most effective method for removing minerals from water (EPA). That statement is about humidifier water, and it does not say that dehumidifier water needs to be distilled (EPA).
The same EPA guidance says to use water with low mineral content to prevent the build-up of scale and the dispersal of minerals into the air (EPA). It notes that not all bottled water is produced using demineralization processes (EPA), and that bottled water labeled 'spring', 'artesian' or 'mineral' has not been treated to remove mineral content (EPA).
Frequently asked
Is dehumidifier water distilled?
EPA describes condensate from air conditioners as essentially distilled water (EPA). That description is about air-conditioner systems, so check the manual for how your dehumidifier's water should be handled. A licensed technician or the manufacturer can confirm the right use for your unit.
Can I drink water from my dehumidifier?
Read the manufacturer's manual before drinking it. EPA reported that all test results for one commercial generator indicated its water was microbiologically safe for human consumption (EPA). That result covers one commercial unit, not household dehumidifiers. CDC says germs that grow in water-using devices generally will not make you sick if you swallow them, but CDC does not say the water is safe to drink (CDC). If the manual does not address drinking, ask the manufacturer before you use the water.
Where should the drain hose go?
FSEC advises that draining condensate from a dehumidifier to a sink is often the suggested method (FSEC). Keep drain hoses away from electrical cords and connections (ENERGY STAR).
Does the bucket shut off when it is full?
For portable units with a removable bucket, ENERGY STAR says there is typically an automatic shutoff when the bucket is full (ENERGY STAR). Confirm that feature in your model's manual.
Can indoor humidity cause mold?
ENERGY STAR says indoor humidity above the optimum range may promote mold growth (ENERGY STAR). Compare room readings with the optimum humidity range. EPA says higher humidity levels may encourage the growth of biological organisms in the home (EPA).
How quickly should wet items be dried?
EPA says that in most cases mold will not grow if wet or damp items are dried within 24 to 48 hours (EPA). That applies to wet building materials and items, not water held in an appliance (EPA).
Should I clean a dehumidifier bucket the way a humidifier tank is cleaned?
EPA's cleaning instruction is for humidifier tanks: empty the tank and use a brush or other scrubber to clean it (EPA). EPA does not give that instruction for dehumidifier buckets, so follow the cleaning steps in your manual.
Related
- Office temperature: what OSHA and EPA say
- Radiant barriers in an attic: placement and dust
- Types of humidifiers: how each kind works
Need dehumidifier or HVAC help? Blume Mechanical Service (CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: ENERGY STAR — Dehumidifiers | ENERGY STAR (https://www.energystar.gov/products/dehumidifiers) · EPA — Atmospheric Water Generation Research (archived January 19, 2021 snapshot) (https://19january2021snapshot.epa.gov/water-research/atmospheric-water-generation-research_.html) · EPA — Using HVAC Condensate as a Reuse Option for Water Conservation (8th ASM Conference abstract) (https://cfpub.epa.gov/si/si_public_record_report.cfm?Lab=NERL&count=25&dirEntryId=344037&displayIt=Yes&searchall='water+treatment'+AND+chlorination+OR+chloramine+OR+biofilm+OR+monochloramine+OR+'chlorine+inactivation'+NOT+radiological&showCriteria=1&sortBy=pubDateYear&startIndex=26&subject=Homeland+Security+Research&view=desc) · EPA — Mold Course, Chapter 4 (https://www.epa.gov/mold/mold-course-chapter-4) · FSEC — Mold Growth, Florida Solar Energy Center, University of Central Florida (https://energyresearch.ucf.edu/consumer/buildings/building-science-basics/mold-growth/) · CDC — Preventing Drinking Water-Related Illnesses (https://www.cdc.gov/drinking-water/prevention/) · EPA — Use and Care of Home Humidifiers (https://www.epa.gov/indoor-air-quality-iaq/use-and-care-home-humidifiers) · FSEC — Another Aspect of Duty Cycling, FSEC-PF-118-87, Florida Solar Energy Center (https://www.fsec.ucf.edu/en/publications/html/FSEC-PF-118-87/index.htm)