HSPF2 is the heating season performance factor for heat pumps, shown in British thermal units per watt-hour, or Btu/Wh (U.S. Department of Energy). Some documentation uses the older name HSPF for heat pump heating efficiency (Lawrence Berkeley National Laboratory). Read the figure on the unit's nameplate or data sheet, and ask the installer to confirm it is HSPF2 for the model you buy.
This guide explains the HSPF2 heating rating for heat pumps in plain terms. It covers the unit of measure, the older HSPF name and test method, a 2004 Florida field study (Florida Solar Energy Center), and how heat pumps are often selected. Read it before you compare two heat pumps, and bring the questions at the end of this page to your installer.
What HSPF2 measures
HSPF2 stands for heating season performance factor, and it is the heating rating for heat pumps (U.S. Department of Energy). The figure is shown in British thermal units per watt-hour, written Btu/Wh (U.S. Department of Energy).
Read the figure in Btu/Wh and compare only figures that carry the same name and unit. Do not place it next to a cooling rating and treat the two as the same measure.
Why you may see the older HSPF name
The Home Energy Saver documentation at Lawrence Berkeley National Laboratory says heat pump heating efficiency is shown as HSPF, the Heating Seasonal Performance Factor (Lawrence Berkeley National Laboratory). That documentation describes the legacy system and uses the older name, not the HSPF2 test method (Lawrence Berkeley National Laboratory).
A 2004 Florida Solar Energy Center paper describes the older HSPF rating as based on test data taken at outdoor temperatures of 47, 35 and 17 degrees Fahrenheit (Florida Solar Energy Center). Keep that test basis in mind when you read an older document next to a current label.
How the labeled number was set
A 2004 Florida Solar Energy Center paper says the rated HSPF from ARI 210/240 is based on the temperature in Climate Region IV (2000-2500 heating load hours) (Florida Solar Energy Center).
Ask your installer which climate and test basis the unit's rating assumes, and whether your home sits in a colder or milder place than that basis. When you compare two units, write their HSPF2 figures and their stated rating basis side by side on one page, so the comparison stays clear when you talk with the installer.
What Florida field data showed
Sub-metered data from more than 160 Florida homes showed that thermostat setback adversely affected operating heat pump performance (Florida Solar Energy Center). Do not read that finding as a fixed loss for your house, and keep your thermostat plan in mind when you set a schedule.
In the same field data, the implied seasonal COP was 1.45, compared with the commonly claimed 2.0 for an HSPF of 6.8 (Florida Solar Energy Center). This is a 2004 study (Florida Solar Energy Center).
COP is a different measure
COP, the coefficient of performance, is defined separately from HSPF2 (ENERGY STAR). ENERGY STAR defines COP as the ratio of the average rate of space heating delivered to the average rate of electrical energy consumed (ENERGY STAR).
Keep COP and HSPF2 apart when you read two specification sheets, because each number answers a different question.
Cold weather and ENERGY STAR criteria
ENERGY STAR says its certification requires third-party verified performance for low temperatures, with testing down to 5 degrees Fahrenheit (ENERGY STAR). It also says many new ENERGY STAR certified air-source heat pumps excel at providing space heating even in the coldest of climates (ENERGY STAR).
ENERGY STAR says a heat pump is more energy-efficient than a furnace or boiler, even during winter (ENERGY STAR). That statement is general, so ask the manufacturer for heating performance at the low temperatures you expect where you live.
How heat pumps are often selected
The U.S. Department of Energy says residential heat pumps are frequently selected based on their cooling capacity (U.S. Department of Energy). A cooling figure is one part of the choice, and the heating figure deserves the same attention before you sign.
The heating rating is one input to the decision. Pair it with the size of the system, the duct work and the installation plan that your installer proposes for your home. A heating figure gives you one input to weigh, so combine it with the other specifications, the home layout and the advice of a licensed contractor before you choose.
Checking the number before you buy
Find the HSPF2 figure on the unit's nameplate, the manufacturer's data sheet or the owner's manual, and write down the model number that goes with it. Ask a licensed contractor to explain the number in writing before you agree to a purchase.
Blume Mechanical Service repairs, installs and maintains HVAC and refrigeration equipment, and it is brand-agnostic. Keep the written figures with your quote and the model number, so you can check them against the equipment that is installed.
Frequently asked
What does HSPF2 stand for?
HSPF2 stands for heating season performance factor (U.S. Department of Energy). It is shown in British thermal units per watt-hour, or Btu/Wh (U.S. Department of Energy).
Is HSPF the same as HSPF2?
The Lawrence Berkeley National Laboratory documentation uses the older name HSPF for heat pump heating efficiency (Lawrence Berkeley National Laboratory). That documentation describes the legacy system and not the HSPF2 test method, so check which name and test a figure uses before you compare it. Write both names on your comparison sheet so you do not mix the two when you talk with an installer.
Is COP the same as HSPF2?
ENERGY STAR defines COP separately from HSPF2 (ENERGY STAR). ENERGY STAR defines COP as the ratio of the average rate of space heating delivered to the average rate of electrical energy consumed (ENERGY STAR).
Can a heat pump heat in very cold weather?
ENERGY STAR says many new ENERGY STAR certified air-source heat pumps excel at providing space heating even in the coldest of climates (ENERGY STAR). Its certification also requires third-party verified performance for low temperatures, with testing down to 5 degrees Fahrenheit (ENERGY STAR). Ask the manufacturer for heating performance at the temperatures you expect.
Is a heat pump more efficient than a furnace?
ENERGY STAR says a heat pump is more energy-efficient than a furnace or boiler, even during winter (ENERGY STAR). The statement is general, so ask your installer for figures that match your home and your equipment choice.
Should I choose a heat pump by its HSPF2 alone?
The U.S. Department of Energy says residential heat pumps are frequently selected based on their cooling capacity (U.S. Department of Energy). Read the HSPF2 figure alongside the cooling figure and the installation plan before you decide.
Related
- ENERGY STAR heat pump and AC efficiency criteria
- Heat pump water heaters: how they work and where they fit
- SEER and SEER2 Ratings Explained
Questions about a heat pump's heating rating? Blume Mechanical Service (license CAC-1822618) serves Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: U.S. Department of Energy (FEMP) — Purchasing Energy-Efficient Residential Air-Source Heat Pumps (https://www.energy.gov/cmei/femp/purchasing-energy-efficient-residential-air-source-heat-pumps) · Lawrence Berkeley National Laboratory — Heating and Cooling Equipment Efficiencies - Legacy System (https://hes-documentation.lbl.gov/calculation-methodology/calculation-of-energy-consumption/legacy/heating-and-cooling-calculation/heating-and-cooling-equipment-efficiencies-legacy-system) · U.S. EPA ENERGY STAR — Heat Pump Equipment Key Product Criteria (https://www.energystar.gov/products/air_source_heat_pumps/key-product-criteria) · U.S. EPA ENERGY STAR — Air-Source Heat Pumps (https://www.energystar.gov/products/air_source_heat_pumps) · University of Central Florida, Florida Solar Energy Center — Climate Impacts on Heating Seasonal Performance Factor (HSPF) and Seasonal Energy Efficiency Ratio (SEER) for Air Source Heat Pumps (https://www.fsec.ucf.edu/en/publications/html/FSEC-PF-413-04/)