HVAC, explained
ENERGY STAR heat pump and AC efficiency criteria
ENERGY STAR sets minimum HSPF2, SEER2 and EER2 numbers for heat pumps, and the numbers depend on the tier and equipment type (ENERGY STAR). For a standard-tier split-system heat pump, the minimums are 7.8 HSPF2, 15.2 SEER2 and 11.0 EER2 (ENERGY STAR). Separate tax-credit thresholds apply to central air conditioners, so check the eligibility page before you buy (ENERGY STAR).
ENERGY STAR sets minimum ratings for heat pumps, and the federal tax credit uses separate eligibility numbers for central air conditioners (ENERGY STAR). The sections below explain what HSPF2 stands for, the standard and cold-climate tier minimums, and the tax-credit thresholds for central air conditioners. The page is written for Tampa Bay homeowners who are comparing a heat pump or planning an air conditioner replacement. Use the numbers as a checklist, then confirm each one against the listing for the exact model you are considering.
What HSPF2 measures
HSPF2 is the heating season performance factor for heat pumps, shown in British thermal units per watt-hour (DOE). ENERGY STAR's standard-tier split-system line lists HSPF2, SEER2 and EER2 together (ENERGY STAR).
Keep the model number handy so you can match each listing to the exact unit.
Standard-tier minimums for split-system heat pumps
ENERGY STAR's standard tier requires split-system heat pumps to reach at least 7.8 HSPF2, 15.2 SEER2 and 11.0 EER2 (ENERGY STAR). The standard-tier split-system numbers do not cover single-package units (ENERGY STAR).
Check that the model is a split system before you apply these numbers.
Standard-tier minimums for single-package units
ENERGY STAR's standard tier requires single-package equipment, including gas/electric package units, to reach at least 7.2 HSPF2, 15.2 SEER2 and 10.0 EER2 (ENERGY STAR).
Use the set that matches your equipment type, and do not swap one set for the other. Ask the contractor to write the equipment type, the model number and the three ratings on the quote.
The cold-climate tier
ENERGY STAR publishes a separate cold-climate tier with its own minimums (ENERGY STAR). For non-ducted split systems, the cold-climate tier requires at least 8.5 HSPF2 and 15.2 SEER2 (ENERGY STAR). For ducted split systems, it requires at least 8.1 HSPF2 and 15.2 SEER2 (ENERGY STAR). For single-package heat pumps, it requires at least 8.1 HSPF2 and 15.2 SEER2 (ENERGY STAR).
The cold-climate minimums are listed separately from the standard-tier minimums (ENERGY STAR). Keep the two tiers apart when you read a quote.
ENERGY STAR requires third-party verified low-temperature performance for air-source heat pumps, tested down to 5°F (ENERGY STAR). ENERGY STAR says a cold climate air-source heat pump will continue working at temperatures below 5°F (ENERGY STAR). DOE says backup electric-resistance heating elements are inefficient, so their use should be kept to a minimum (DOE).
Tax-credit thresholds for central air conditioners
The ENERGY STAR central air conditioner tax-credit page sets eligibility numbers that are separate from the heat pump criteria (ENERGY STAR). Effective January 1, 2025, split-system central air conditioners must meet 17.0 SEER2 and 12.0 EER2 to be eligible (ENERGY STAR). Packaged central air conditioners must meet 16.0 SEER2 and 11.5 EER2 to be eligible (ENERGY STAR).
These are eligibility rules for the credit, not the ENERGY STAR product minimums (ENERGY STAR). Check which rule covers your product before you apply these numbers to a heat pump.
Check the tax-credit window before you buy
The tax credit covers products purchased and installed from January 1, 2023 through December 31, 2025 (ENERGY STAR). The page lists that window as ending on December 31, 2025 (ENERGY STAR), so check the page for any later extension before you plan a purchase.
Ask a tax preparer how a credit would apply to your own return.
What FSEC says about Florida homes
FSEC says that in Central and North Florida, a homeowner should select a heat pump (FSEC). The same FSEC page says the heat pump advice does not apply in South Florida (FSEC). Check which region your address is in before you apply this advice.
FSEC recommends installing very high efficiency air conditioners and heat pumps rated SEER 17 or greater (FSEC). That is the older SEER rating, not SEER2 (FSEC). FSEC says higher SEER ratings will produce greater savings, but air conditioning size or capacity matters too (FSEC).
FSEC also says bigger is not necessarily better when it comes to cooling (FSEC). At replacement, FSEC advises asking the contractor for a sizing calculation and resisting the urge to add a half ton (FSEC). FSEC advises replacing an air conditioning system older than 10 years with a high efficiency one (FSEC).
How to compare two quotes and when to call a technician
Ask each contractor for the full model number and the rating sheet for that model. Write the three values next to the tier each unit is listed under, so the comparison stays on the same basis. Keep the rating comparison separate from the price comparison.
Call a licensed technician for sizing, installation and any question about whether a unit meets a particular tier or credit rule. Blume Mechanical Service repairs, installs and maintains HVAC equipment and is brand-agnostic.
Frequently asked
What does HSPF2 measure?
HSPF2 is the heating season performance factor for heat pumps, shown in British thermal units per watt-hour, or Btu/Wh (DOE).
What are the standard-tier minimums for a split-system heat pump?
ENERGY STAR's standard tier requires at least 7.8 HSPF2, 15.2 SEER2 and 11.0 EER2 for split systems (ENERGY STAR). These numbers do not apply to single-package units (ENERGY STAR).
Do single-package heat pumps use different numbers?
Yes. ENERGY STAR's standard tier requires at least 7.2 HSPF2, 15.2 SEER2 and 10.0 EER2 for single-package equipment, including gas/electric package units (ENERGY STAR).
What is the cold-climate tier?
ENERGY STAR publishes a separate cold-climate tier with its own minimums (ENERGY STAR). Non-ducted split systems need at least 8.5 HSPF2 and 15.2 SEER2, and ducted split systems need at least 8.1 HSPF2 and 15.2 SEER2 (ENERGY STAR).
Does a cold-climate heat pump keep working below 5°F?
ENERGY STAR says a cold climate air-source heat pump will continue working at temperatures below 5°F (ENERGY STAR). ENERGY STAR requires third-party verified low-temperature performance for air-source heat pumps, tested down to 5°F (ENERGY STAR).
Which SEER2 and EER2 numbers does the central air conditioner tax credit require?
Split-system central air conditioners must meet 17.0 SEER2 and 12.0 EER2 from January 1, 2025 (ENERGY STAR). Packaged central air conditioners must meet 16.0 SEER2 and 11.5 EER2 (ENERGY STAR). These are eligibility numbers for the credit, not product minimums (ENERGY STAR).
Related
- Heat pump water heaters: how they work and where they fit
- Variable-speed heat pumps: cold weather and humidity
- SEER and SEER2 Ratings Explained
Comparing heat pump or air conditioner ratings for a home in Tampa Bay? Blume Mechanical Service (license CAC-1822618), founded in 2009, serves Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: U.S. Department of Energy (DOE) — Purchasing Energy-Efficient Residential Air-Source Heat Pumps (https://www.energy.gov/cmei/femp/purchasing-energy-efficient-residential-air-source-heat-pumps) · U.S. EPA ENERGY STAR — Heat Pump Equipment Key Product Criteria (https://www.energystar.gov/products/air_source_heat_pumps/key-product-criteria) · U.S. EPA ENERGY STAR — Air Source Heat Pumps (https://www.energystar.gov/products/air_source_heat_pumps) · U.S. EPA ENERGY STAR — Central Air Conditioners Tax Credit (https://www.energystar.gov/about/federal-tax-credits/central-air-conditioners) · Energy Research, UCF Florida Solar Energy Center (FSEC) — How to Reduce Energy Costs in Existing Homes – Priorities (https://energyresearch.ucf.edu/consumer/buildings/priorities/)