HVAC, explained
How to Know If an AC Capacitor Is Bad
Carrier names a unit that hums but does not start, warm air from the system, and a unit that turns off and on rapidly as the possible capacitor signs its HVAC experts see most often (Carrier). Bryant lists a humming outdoor unit with a still fan, hard starting, random shutoffs and tripped breakers as signs, and says a capacitor or some other electrical part may add to the strain behind breaker trips (Bryant). Bryant says capacitors can keep a dangerous electrical charge after the power is cut (Bryant).
Carrier describes the capacitor as giving the system an initial boost of energy so the compressor and fan motors can start, and steadying the voltage while they run (Carrier). Bryant says a system may use a start capacitor, a run capacitor or a dual-run capacitor, depending on the system design (Bryant).
A humming, loud or silent outdoor unit
Bryant says a hum with a still fan can mean the capacitor cannot give the motor the energy it needs to start (Bryant). American Standard says units normally hum while running, and that a sound much louder than that can point to a failing capacitor (American Standard). Carrier says a distinct hum from the outdoor unit usually points to a motor that is trying to start without enough torque (Carrier). Lennox says a buzzing or humming noise from the outside unit may mean the capacitor has failed (Lennox). Lennox notes that some units run quietly, but a low hum should still be there (Lennox). Lennox says still fan blades with no sound are an obvious sign the outdoor unit may not be working (Lennox).
A fan that stays still, hard starting and warm air
Carrier says a fan that hums without spinning can point to a failed capacitor, though a failing motor can also be behind it (Carrier fan guide). Carrier also lists a slow start-up and an AC that is not blowing cold air as other signs (Carrier fan guide). Bryant describes hard starting as an AC that struggles to start and needs more time than normal to switch on (Bryant). Trane lists an AC that is slow to begin a cooling cycle, or that will not start at all (Trane). Carrier says lukewarm air from a running system may mean a weak capacitor is not bringing the compressor up to full speed (Carrier). Bryant lists blowing warm air, where the fan runs but the compressor does not engage (Bryant).
Shutoffs, short cycling, breaker trips and high bills
Bryant lists random shutoffs, when the system cycles off before reaching the set temperature (Bryant). American Standard describes short cycling as ending a cycle early, and says that can point to a failing capacitor (American Standard). Carrier says a failing capacitor often has trouble keeping the compressor running, and the unit can shut off and restart rapidly (Carrier). Trane lists an AC that switches off at random (Trane). Bryant counts a tripping breaker as a sign, and says a capacitor or some other electrical part may add to the strain behind repeated trips (Bryant). Carrier says not to force a breaker that trips again right away, and treats it as a deeper electrical problem for a professional technician (Carrier fan guide). Carrier says a degrading capacitor can leave the motors drawing more amperage, which can raise utility bills (Carrier). Trane lists unreasonably high energy bills as a symptom (Trane).
Warm air, a silent outdoor unit, smoke and burning smell
Lennox says warm air from the vents can go along with an outdoor unit that is not turning on, a cause people tend to miss (Lennox). Lennox says a failed capacitor can prevent the outdoor unit from starting even when cooling is called for (Lennox). American Standard says a burning smell or smoke near the outdoor unit could also signal a failed capacitor (American Standard). Trane includes smoke and a burning smell from the unit on its symptom list (Trane). Trane says that for heat pumps, a burning rubber or burning electrical odor can come from parts that overheat, and a failing capacitor is one possible reason (Trane). American Standard says that if smoke or a burning smell comes from the outdoor unit, switch the unit off right away and phone an HVAC company (American Standard). American Standard says a unit that will not turn on at all can have many causes, and a failed capacitor is among them (American Standard).
What a homeowner can check, and what goes to a contractor
A homeowner can start by seeing whether the thermostat is on cool, with its target setting under the current room temperature (Carrier fan guide). American Standard says the filter should be changed regularly, every 30 to 90 days (American Standard blog). It also says not to block vents with furniture or drapes, and to keep plants and debris away from the outdoor unit (American Standard blog). Carrier strongly recommends that homeowners not try to replace an AC capacitor themselves (Carrier). Carrier warns that capacitors hold high-voltage electricity, which can cause serious injury or death, even after the power is cut (Carrier). Trane advises against trying to swap out the run capacitor on your own (Trane).
Frequently asked
Do I need to call a pro for this?
Yes. Electrical work, including anything that involves a capacitor, belongs to a licensed HVAC contractor. A homeowner can check the thermostat settings, the air filter, that vents and returns are not blocked, and that the area around the outdoor unit is clear.
Can I check the capacitor myself?
No. American Standard says it does not recommend that a homeowner test or replace a bad AC capacitor, and notes the parts are high-voltage and connected to wiring (American Standard).
Can I run the AC with a bad capacitor?
No. Carrier advises against operating the unit while the capacitor is bad, since that can permanently harm the compressor and fan motors through extra strain (Carrier).
What does a clicking sound at the outdoor unit mean?
Trane says that for heat pumps, clicking every few seconds near the outdoor unit may be a sign of a bad capacitor (Trane). If the start capacitor has failed, the motor may also give off a loud hum (Trane).
What is a dual-run capacitor?
Bryant says a dual-run capacitor puts two capacitor functions into one unit, and that it commonly serves the compressor and the condenser fan (Bryant).
Related
- AC Compressor Problems: Turning On and Off, and a Bad Compressor
- AC Capacitor and Fan Failures: What the Parts Do and Who Should Replace Them
- AC Not Turning On: What to Check Before You Call
- AC Troubleshooting: From Symptom to Likely Cause
Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.
Sources: Bryant, https://www.bryant.com/en/ca/products/air-conditioners/ac-capacitor-replacement/ · American Standard, https://www.americanstandardair.com/resources/blog/ac-capacitors-guide/ · Carrier, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/ac-capacitor/ · Carrier fan guide, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/ac-fan-not-spinning/ · Lennox, https://www.lennox.com/residential/lennox-life/consumer/outside-ac-unit-not-turning-on · Trane, https://www.trane.com/residential/en/resources/blog/air-conditioner-capacitors-what-they-are-and-why-theyre-such-a-big-deal/ · Trane, https://www.trane.com/residential/en/resources/troubleshooting/heat-pumps/heat-pump-capacitor/ · Trane, https://www.trane.com/residential/en/resources/troubleshooting/air-conditioners/ac-fan-not-working/ · American Standard blog, https://www.americanstandardair.com/resources/blog/air-conditioner-not-working-reasons/