Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

Furnace flame sensor: what it does and who cleans it

A furnace flame sensor is a small safety device that detects whether a flame is present in the burner assembly (Carrier). Carrier identifies a dirty or faulty flame sensor as one possible cause when a gas furnace ignites and then shuts off shortly afterward (Carrier). Carrier recommends having the flame sensor maintained by a trained HVAC professional (Carrier).

A flame sensor is a small part, but Carrier says it is how a gas furnace confirms that combustion is occurring. This page explains what the sensor does, what Carrier reports about why it fails, and why maintaining it belongs with a trained technician.

What the flame sensor does

A furnace flame sensor is a small safety device that detects whether a flame is present in the burner assembly (Carrier). Carrier describes the flame sensor as a metallic rod located on the burner assembly that detects the presence of a flame when the gas is on (Carrier).

Carrier says the sensor does this by passing a small electrical current through the flame, a process called flame rectification (Carrier). Carrier says this process confirms that combustion is occurring (Carrier).

Carrier says a flame sensor, also called a flame rod, is used in modern intermittent-ignition furnaces and works through electrical current rectification (Carrier). Carrier says a thermocouple is used in older standing-pilot furnaces, where it holds the gas valve open when heated by the pilot flame (Carrier).

How the sensor protects the furnace

If the sensor cannot confirm combustion, it shuts the furnace down to prevent gas buildup (Carrier). Carrier says the flame sensor is a critical safety component that prevents unburned gas from accumulating in a home (Carrier).

Carrier says the control system can close the gas valve and shut down the furnace as a safety measure when it does not receive the required flame-sensing signal (Carrier).

Signs the sensor may be failing

Carrier identifies a dirty or faulty flame sensor as one possible cause when a gas furnace ignites and then shuts off shortly afterward (Carrier). Carrier says a furnace can start and then shut off when the control system does not receive the expected flame-sensing signal (Carrier).

The number of ignition attempts before lockout varies by model and control system (Carrier). Carrier says homeowners should consult the installation or service documentation for their furnace rather than assume a universal retry count (Carrier).

What causes a flame sensor to fail

Carrier lists carbon buildup or oxidation as the most common cause of flame sensor failure (Carrier). Carrier says a thin layer of residue on the sensor rod insulates it, preventing it from detecting the flame (Carrier).

Carrier says the ceramic sleeve that holds the rod can crack, causing a short circuit (Carrier). Carrier also notes that loose wiring, poor grounding and misalignment can contribute to flame-sensor problems (Carrier).

Carrier specifically identifies oxidation or carbon buildup on the sensor rod as common causes of a dirty or faulty flame sensor (Carrier).

Why the sensor is not always the cause

Carrier says problems with ignition, wiring, grounding, gas supply, combustion or the furnace control system can produce similar behavior (Carrier).

Why a trained technician should maintain the sensor

Carrier recommends having internal furnace components such as the flame sensor maintained by a trained HVAC professional (Carrier). Carrier says bypassing or removing the flame sensor is dangerous and should never be attempted (Carrier). Carrier says gas furnace repairs can involve combustion, electrical and gas-supply hazards and may require a qualified professional depending on the work and local requirements (Carrier).

If you smell gas, Carrier says to leave the area and contact your gas utility and an HVAC professional (Carrier). Carrier says not to attempt to diagnose or repair a suspected gas leak yourself (Carrier).

When cleaning does not fix the problem

Carrier says that if cleaning does not resolve the issue, the sensor or another component in the flame-sensing circuit may require service (Carrier). Carrier says that if the sensor rod shows visible oxidation or carbon buildup and the furnace resumes normal operation after cleaning, replacement is not necessary (Carrier).

Carrier says to replace the sensor if the furnace continues to short-cycle after cleaning, or if the rod or porcelain insulator is visibly cracked or damaged (Carrier).

Maintenance and how long the sensor lasts

Carrier says there is no universal service life for a furnace flame sensor (Carrier). Carrier says its longevity can vary based on furnace design, operating conditions, combustion quality and maintenance (Carrier).

Rather than specifying a fixed lifespan, Carrier recommends annual professional furnace maintenance and inspection of internal components such as the flame sensor (Carrier). Carrier says annual furnace tune-ups can help identify buildup, wiring problems and other conditions before they result in a heating interruption (Carrier).

Frequently asked

What does a furnace flame sensor do?

A furnace flame sensor is a small safety device that detects whether a flame is present in the burner assembly (Carrier). Carrier says the sensor does this by passing a small electrical current through the flame (Carrier).

Why does a furnace start and then shut off?

Carrier identifies a dirty or faulty flame sensor as one possible cause when a gas furnace ignites and then shuts off shortly afterward (Carrier). Carrier says problems with ignition, wiring, grounding, gas supply, combustion or the furnace control system can produce similar behavior (Carrier).

Should a homeowner clean the flame sensor?

Carrier recommends having internal furnace components such as the flame sensor maintained by a trained HVAC professional (Carrier). Carrier says bypassing or removing the flame sensor is dangerous and should never be attempted (Carrier).

What causes the sensor rod to get dirty?

Carrier lists carbon buildup or oxidation as the most common cause of flame sensor failure (Carrier). Carrier says a thin layer of residue on the sensor rod insulates it, preventing it from detecting the flame (Carrier).

What if cleaning does not fix the furnace?

Carrier says that if cleaning does not resolve the issue, the sensor or another component in the flame-sensing circuit may require service (Carrier). Carrier says to replace the sensor if the furnace continues to short-cycle after cleaning (Carrier).

Does a cracked insulator matter?

Carrier says the ceramic sleeve that holds the rod can crack, causing a short circuit (Carrier). Carrier says to replace the sensor if the rod or porcelain insulator is visibly cracked or damaged (Carrier).

Related

Need a furnace checked? Blume Mechanical Service (license CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.

Sources: Carrier — Furnace Flame Sensor: What It Is, Why It Fails, and How to Fix It (https://www.carrier.com/us/en/residential/hvac-resources/furnaces/furnace-flame-sensor/)

Search Google for how to clean flame sensor on furnace