HVAC, explained

Data center cooling basics for facility managers

An air-side economizer brings cool air from outdoors into a building and distributes it to the servers (ENERGY STAR). ENERGY STAR says that even in northern Florida, an air-side economizer can be utilized for about half the year (ENERGY STAR). Humidity control can cut into the savings achieved by an air-side economizer (ENERGY STAR).

The data center cooling measures that ENERGY STAR describes are covered below. It explains outside-air economizers, cooling towers, chilled water, and airflow measures such as containment and blanking panels. Many of the reported results come from single facilities, so they show what happened at those sites rather than what every facility will see (ENERGY STAR). Each fact names its source, so you can check it against the page it came from.

How an air-side economizer works

An air-side economizer brings cool air from outdoors into a building and distributes it to the servers (ENERGY STAR). ENERGY STAR says you can cool a data center for almost free by using air from outside, weather permitting (ENERGY STAR).

The words weather permitting matter. The measure depends on outdoor conditions, so the hours it can run depend on the weather (ENERGY STAR).

The sections below cover the Florida limits and the measures that ENERGY STAR lists beyond outside air.

Florida and hot, humid conditions

Even in northern Florida, an air-side economizer can be utilized for about half the year (ENERGY STAR). That figure is for northern Florida only, and it applies to a data center setting.

In some cooler climates, such as San Francisco, air-side economization is possible for just about every day of the year (ENERGY STAR). That example describes a cooler climate, not a hot, humid one.

Humidity control can cut into the savings achieved by an air-side economizer (ENERGY STAR). Plan for humidity control when you estimate how many hours outside air can replace mechanical cooling.

Case study results from single facilities

In 2008, a company began operating a data center in Belgium that used only outside air for cooling (ENERGY STAR). That facility used outside air for partial free cooling more than 98 percent of the time (ENERGY STAR).

The same facility's water plant operates nearly 90 percent less frequently than a typical data center's (ENERGY STAR). Its results come from one site in a cool climate, so they are not a forecast for a Florida building.

One facility reported total energy savings of 45 percent after it used an air-side economizer (ENERGY STAR). ENERGY STAR also notes that a number of case studies document air-side economizer savings (ENERGY STAR). Ask for those case studies when you compare options.

Cooling towers and chilled water

ENERGY STAR advises using a cooling tower instead of a mechanical chiller to supply chilled water for cooling the data center (ENERGY STAR). Confirm the site conditions it needs with a licensed engineer.

ENERGY STAR advises reducing the cost of chilled water by up to 70 percent (ENERGY STAR). Ask how the savings were measured before you rely on it.

One company reported that its data center reduced cooling system energy use by nearly 90 percent (ENERGY STAR). That was one company's result, not a typical one.

Airflow management and containment

Inexpensive grommets, diffusers, and blanking panels can keep cold air from mixing with hot exhaust air (ENERGY STAR). These are low-cost parts that address airflow at the rack level.

Rows of server racks should be oriented so that the fronts of servers face each other (ENERGY STAR). In addition, the backs of server racks should also face each other, forming hot (exhaust) and cold aisles (ENERGY STAR).

In data centers with hot and cold aisle arrangements, containment systems can reduce energy expense by 5 percent to 10 percent (ENERGY STAR). A Department of Energy estimate, cited by ENERGY STAR, gives a fan energy use reduction of 20 percent to 25 percent when used with containment (ENERGY STAR).

Monitoring and infrastructure management

Data center infrastructure management, or DCIM, provides information that lets you right-size the infrastructure (ENERGY STAR). ENERGY STAR says that information can reduce energy costs by as much as 30 percent (ENERGY STAR).

As much as is an upper bound, not an expected result. Use the figure to set a target for your own metering rather than a promised saving.

Track the results of each change on the same meters, so you can see which measure produced which effect.

Questions to ask before you change the cooling plan

Ask your licensed mechanical engineer or contractor to check the outdoor air and humidity conditions at your site. Ask which measures the source figures came from, and whether those facilities resemble yours.

Compare each measure on the same points: the climate it was tested in, the year, and the equipment it applied to. Keep the notes with the design file so later staff can see why a change was made.

For the cooling equipment itself, an HVAC check can confirm chillers, cooling towers and air handlers are running as designed.

Frequently asked

What is an air-side economizer?

An air-side economizer brings cool air from outdoors into a building and distributes it to the servers (ENERGY STAR). ENERGY STAR says it depends on weather conditions (ENERGY STAR).

Can an economizer work in northern Florida?

ENERGY STAR says that even in northern Florida, an air-side economizer can be utilized for about half the year (ENERGY STAR). That figure is for northern Florida only.

Does humidity affect economizer savings?

Humidity control can cut into the savings achieved by an air-side economizer (ENERGY STAR). Plan for it when you estimate outside-air hours.

How much can containment systems save in hot and cold aisle arrangements?

In data centers with hot and cold aisle arrangements, containment systems can reduce energy expense by 5 percent to 10 percent (ENERGY STAR).

Are cooling towers better than chillers?

ENERGY STAR advises using a cooling tower instead of a mechanical chiller to supply chilled water for cooling the data center (ENERGY STAR). Confirm the site conditions with a licensed engineer.

Are the savings figures typical?

Many results come from single facilities (ENERGY STAR). Treat each figure as a reported result for one site, not a promised saving for yours.

Related

Need service on the cooling equipment at your facility? Blume Mechanical Service (CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.

Sources: ENERGY STAR (U.S. EPA and DOE) — Use an Air-Side Economizer (https://www.energystar.gov/products/data_center_equipment/16-more-ways-cut-energy-waste-data-center/use-air-side-economizer) · ENERGY STAR (U.S. EPA and DOE) — 16 More Ways to Cut Energy Waste in the Data Center (https://www.energystar.gov/products/data_center_equipment/16-more-ways-cut-energy-waste-data-center)