Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

Commercial HVAC seasonal maintenance checklist

Regularly change or clean HVAC filters every month during peak cooling or heating season (ENERGY STAR). Clean the evaporator and condenser coils on heat pumps, air-conditioners, or chillers (ENERGY STAR).

A seasonal maintenance checklist gives facility staff a fixed list of checks for heating, cooling and refrigeration equipment. ENERGY STAR publishes a checklist for commercial buildings that covers these checks (ENERGY STAR). The items below follow that checklist, grouped by the equipment they affect.

Filters and coils

Regularly change or clean HVAC filters every month during peak cooling or heating season (ENERGY STAR). Dirty filters cost more to use, overwork the equipment, and result in lower indoor air quality (ENERGY STAR). Clean the evaporator and condenser coils on heat pumps, air-conditioners, or chillers (ENERGY STAR). Dirty coils inhibit heat transfer, so keeping coils clean saves energy (ENERGY STAR). The filter size and coil type should be read from the unit label before the first check of the season. The filter size is listed on the unit label, and the manufacturer can confirm it before a replacement is ordered.

Thermostats and set points

Calibrate thermostats to ensure that their ambient temperature readings are correct, and adjust temperature set points for seasonal changes (ENERGY STAR). If a thermostat's readings look wrong, the equipment manual or the manufacturer should be consulted before any setting is changed.

Vents, doors and airflow

Make sure that areas in front of vents are clear of furniture and paper (ENERGY STAR). Keep exterior doors closed while running your HVAC (ENERGY STAR).

Insulation and air leaks

Visually inspect insulation on all piping, ducting and equipment for damage (ENERGY STAR). Repair damaged insulation and replace missing insulation with thicknesses calculated for the operating and ambient conditions of the mechanical system (ENERGY STAR). Plug air leaks with weather stripping and caulking (ENERGY STAR). Repair steam trap leaks; replace malfunctioning steam traps (ENERGY STAR).

Refrigeration service

Have large and walk-in refrigeration systems serviced at least annually (ENERGY STAR). This includes cleaning, refrigerant top off, lubrication of moving parts, and adjustment of belts (ENERGY STAR). This will help ensure efficient operation and longer equipment life (ENERGY STAR). Consider retrofitting existing refrigerators and display cases with anti-sweat door heater controls, and variable speed evaporator fan motors and controls (ENERGY STAR). Over time, trees can attractively shade the facility, and help clean the air (ENERGY STAR). Work on refrigerant circuits should be left to a licensed contractor.

Sun through windows

Use shades and blinds to control direct sun through windows in both summer and winter to prevent or encourage heat gain (ENERGY STAR). During cooling season, block direct heat gain from the sun shining through glass on the east and especially west sides of the facility (ENERGY STAR). During heating season, with the sun low in the south, unobstructed southern windows can contribute solar heat gain during the day (ENERGY STAR).

Energy audits and utility help

Consider energy audits to identify areas where building systems have become inefficient over time and bring them back to peak performance (ENERGY STAR). Ask your utility if they offer free or inexpensive energy audits (ENERGY STAR). Even a new HVAC system, like a new car, will decline in performance without regular maintenance (ENERGY STAR). Where a unit's equipment manual lists a different interval, the manual's interval should be followed, and a licensed contractor can confirm the schedule for the unit.

Annual service and breakdowns

Tune up your heating, ventilation, and air conditioning (HVAC) system with an annual maintenance contract (ENERGY STAR). Your chances of an emergency HVAC breakdown also decrease with regular maintenance (ENERGY STAR). Service intervals for a specific unit are set in its equipment manual, so the manual should be checked before the schedule is fixed.

Frequently asked

How often should commercial HVAC filters be changed?

Regularly change or clean HVAC filters every month during peak cooling or heating season (ENERGY STAR). Dirty filters cost more to use, overwork the equipment, and result in lower indoor air quality (ENERGY STAR).

Why keep condenser and evaporator coils clean?

Clean the evaporator and condenser coils on heat pumps, air-conditioners, or chillers (ENERGY STAR). Dirty coils inhibit heat transfer, so keeping coils clean saves energy (ENERGY STAR).

Do blocked vents affect the system?

Make sure that areas in front of vents are clear of furniture and paper (ENERGY STAR). Vent checks belong on the seasonal list, next to the filter change.

Why check thermostat calibration?

Calibrate thermostats to ensure that their ambient temperature readings are correct, and adjust temperature set points for seasonal changes (ENERGY STAR).

How often should large refrigeration systems be serviced?

Have large and walk-in refrigeration systems serviced at least annually (ENERGY STAR). This includes cleaning, refrigerant top off, lubrication of moving parts, and adjustment of belts (ENERGY STAR).

Can an energy audit help a commercial building?

Consider energy audits to identify areas where building systems have become inefficient over time and bring them back to peak performance (ENERGY STAR). Ask your utility if they offer free or inexpensive energy audits (ENERGY STAR).

Related

Need help with commercial HVAC or refrigeration service? Blume Mechanical Service (license CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment, is brand-agnostic, and serves Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.

Sources: ENERGY STAR (U.S. EPA and DOE) — Checklists (https://www.energystar.gov/buildings/save-energy-commercial-buildings/ways-save/checklists)

Search Google for commercial HVAC seasonal maintenance checklist