Yes, a furnace can leak carbon monoxide into a home (CPSC memo). CPSC says leakage typically takes two failures: the furnace produces elevated CO, and a leakage path opens into the living space (CPSC memo). Lennox says a crack in a furnace heat exchanger can let carbon monoxide reach the air in the home (Lennox). If you suspect carbon monoxide poisoning, get fresh air immediately, leave the house, and go to an emergency room or contact a doctor immediately (EPA).

Lennox says the metal walls of a furnace's heat exchanger keep combustion gases apart from indoor air while letting heat through (Lennox).

What to do first if you suspect carbon monoxide

If poisoning is suspected, EPA's first instruction is to reach fresh air at once and leave the house (EPA). EPA warns that a person who does nothing could pass out and die (EPA). If an alarm sounds, EPA says to make sure it is the CO alarm and not the smoke alarm, and to check whether anyone in the household has symptoms (EPA). EPA says anyone with symptoms should be taken out of the house immediately, that an emergency room is where to go, and that the physician should be told carbon monoxide poisoning is suspected (EPA). If nobody has symptoms, EPA says to air out the home and turn off fuel-burning sources, including a gas or oil furnace (EPA). EPA says to have a qualified technician inspect the fuel-burning appliances and chimneys (EPA). EPA says these symptoms can also come from colds, the flu, or allergies, but warns not to ignore them, especially when more than one person has them (EPA).

How the heat exchanger holds back the gas

Lennox says the metal walls of the exchanger separate harmful gases, including carbon monoxide, from indoor air (Lennox). When the exchanger is intact, Lennox says a furnace should deliver safe, even heat throughout the home (Lennox). Lennox says cracks change that: combustion gases can escape into the air a person breathes (Lennox). Lennox says cracks can develop from normal wear, improper running of the system, missing upkeep or incorrect static pressure (Lennox).

Heating cycles, moisture and sizing

Lennox says each heating and cooling cycle makes the exchanger metal expand and contract, and after years of cycles the metal can weaken and crack (Lennox). Lennox says wrong sizing or poor duct design can speed up that wear (Lennox). Lennox also says moisture around the furnace can cause corrosion that weakens the exchanger walls and makes cracks more likely (Lennox).

Warning signs on the furnace

Lennox points to soot near burners or vents, cycles that are short or temperatures that swing, and rust on the furnace as things to watch for (Lennox). Lennox says rust on the flue pipes can be an early sign (Lennox). Lennox says soot can point to incomplete combustion caused by a crack (Lennox). Lennox says short cycles often point to airflow or combustion problems tied to a damaged exchanger (Lennox). Lennox says a qualified HVAC professional should check the furnace right away when any of these appear (Lennox).

Vent, chimney and flue failures

CPSC says a disconnected vent is a partial or complete separation at a joint in the vent pipe or chimney, or where a pipe section meets the furnace flue outlet (CPSC IDI review). CPSC defines a breached vent, chimney or heat exchanger as an opening in the wall of that component (CPSC IDI review). CPSC groups these breaches and disconnects together, and says each one creates a leakage path into the living space (CPSC IDI review). CPSC places partial or total blockage of vents, chimneys and heat exchangers in one blockage category (CPSC IDI review).

Depressurization and back-drafting

CPSC describes depressurization as air pulled out of the home by exhaust fans or other mechanical means, which can leave a negative pressure at the flue collector or burner compartment (CPSC IDI review). CPSC describes back-drafting as exhaust products flowing back through the flue collector or burner compartment into the living space, rather than out the vent (CPSC IDI review). CPSC says back-drafting may or may not come from depressurization (CPSC IDI review).

Improper venting and combustion air

CPSC's in-depth investigation review covered 83 incidents involving modern gas furnaces and boilers from 2002 to 2009, and it notes that these cases are a subset of all such incidents (CPSC IDI review). CPSC defines improper venting as a vent system installed against the instructions and requirements of the appliance maker, the vent maker, or local building codes (CPSC IDI review). In that review, only 19 of the 83 incident reports said what made the furnace or boiler produce elevated CO (CPSC IDI review). Of those, 10 cited inadequate or blocked combustion or ventilation air, and 7 cited over-firing (CPSC IDI review).

Counts from the CPSC incident review

The 83 incidents in this review, which covers modern gas furnaces and boilers from 2002 to 2009, are only a subset of all such cases, so these counts do not describe furnaces in general (CPSC IDI review). CPSC determined the primary failure mode in 73 of 83 cases (CPSC IDI review). Breached or disconnected vents, chimneys or heat exchangers were the category cited most often, in 16 of 83 cases (CPSC IDI review). Blocked vents, air intakes, heat exchangers or chimneys followed, in 15 of 83 cases (CPSC IDI review). For modern furnaces and boilers, CPSC counted disconnected and blocked vents as the primary failure mode in 31 of 83 cases, linked to 18 of 44 deaths and 96 of 207 probable injuries (CPSC IDI review).

Age of the appliance and standards

CPSC says its data shows leakage can occur well before the appliance reaches its expected lifespan (CPSC IDI review). CPSC says the ANSI Z21 safety devices, such as blocked vent shutoff systems and spill switches, were not designed to respond to disconnected or partially blocked vents, over-firing, or inadequate combustion air (CPSC IDI review). CPSC also says the furnace and boiler standards have no provision for the disconnected-vent scenario (CPSC IDI review).

Repair or replacement

Lennox says a heat exchanger is a sealed component, so repairs are rarely recommended, and replacing the exchanger is typically the safest solution (Lennox). Lennox says depending on the system's age or other damage from the crack, the whole furnace may need replacing (Lennox). Lennox says a qualified HVAC professional can confirm a crack with testing such as combustion analysis or a visual inspection (Lennox).

Frequently asked

What failures let carbon monoxide out of a furnace?

CPSC says leakage typically takes two failures: one that makes the furnace produce elevated CO, and one that opens a leakage path into the living space (CPSC memo). In CPSC's review of 83 incidents involving modern gas furnaces and boilers from 2002 to 2009, disconnected and blocked vents together were the primary failure mode in 31 of those 83 cases (CPSC IDI review).

In CPSC's review of modern furnace and boiler incidents, which failure was cited most often?

In CPSC's review of 83 incidents involving modern gas furnaces and boilers from 2002 to 2009, breached or disconnected vents, chimneys or heat exchangers were the category cited most often, at 16 of 83 cases (CPSC IDI review). Blocked vents, air intakes, heat exchangers or chimneys followed, in 15 of 83 cases (CPSC IDI review).

What are warning signs of a cracked heat exchanger?

Lennox says soot near burners or vents, short cycles, and rust can be warning signs (Lennox). Lennox says rust on the flue pipes can be an early sign (Lennox). Lennox says that if these signs show up, a qualified HVAC professional's inspection should come without delay (Lennox).

Do I need to call a pro for this?

Yes. Lennox says that if warning signs of a cracked heat exchanger show up, the furnace needs a qualified HVAC professional's inspection without delay (Lennox). Inspection, repair, gas, combustion and venting work belongs to a licensed contractor. The checks you can make yourself are the air filter, thermostat settings, and keeping things clear of vents, returns and the outdoor unit. Lennox says keeping vents and registers unblocked helps prevent overheating (Lennox).

Does the age of a furnace matter for carbon monoxide leaks?

CPSC says its data shows leakage can occur well before the appliance reaches its expected lifespan (CPSC IDI review).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: Lennox, https://www.lennox.com/residential/lennox-life/consumer/furnace-cracked-heat-exchanger · CPSC memo, https://www.cpsc.gov/s3fs-public/pdfs/cofurnace.pdf · CPSC IDI review, https://www.cpsc.gov/s3fs-public/Updated_IDI_review_CO_and_modern_furnaces_and_boilers.pdf · EPA, https://www.epa.gov/indoor-air-quality-iaq/protect-your-family-and-yourself-carbon-monoxide-poisoning · EPA, https://www.epa.gov/indoor-air-quality-iaq/what-do-i-do-if-i-suspect-combustion-appliances-are-affecting-my-health