When Was R-22 Phased Out?

R-22 was phased out in steps, and the ban on virgin HCFC-22 production and import took effect on January 1, 2020 (EPA GreenChill). The brochure gives 2020 as the cutoff for making or bringing in R-22, and it says a homeowner does not have to stop running an R-22 air conditioner or replace existing equipment (EPA brochure). The brochure also says manufacture of new R-22 air-conditioning systems is prohibited (EPA brochure).

The brochure lists steps in 2010, 2015, 2020 and 2030 (EPA brochure). The brochure says the country is phasing out R-22 with other chemicals (EPA brochure). Releases of HCFCs deplete the ozone layer and feed into climate change (EPA brochure).

The phaseout schedule by year

The brochure gives January 1, 2010 as a step in the schedule for HCFC-22 and HCFC-142b, and says production and import of R-22 were further limited in 2010 (EPA brochure). The technician FAQ says HCFC-22 imports and production have been limited since 2010 (EPA technician FAQ). The brochure lists January 1, 2015 as a further step in the HCFC schedule, with servicing of refrigeration equipment continuing (EPA brochure). The 2020 step ends what remains of HCFC-22 and HCFC-142b production and import (EPA brochure). The Class II page says the United States must cut HCFC consumption and production step by step, with a full HCFC phaseout in 2030 (EPA Class II page). The last step in the brochure is January 1, 2030, when the remaining HCFC output and imports end (EPA brochure).

Where the phaseout began

EPA set up the phaseout framework in 1993 with a worst-first approach (EPA Class II page). The first chemicals targeted under that approach were HCFC-22, HCFC-141b, and HCFC-142b, which had the highest ozone depletion potentials among HCFCs (EPA Class II page). The Class II page gives an ozone depletion potential range of 0.01 to 0.1 for HCFCs as a group (EPA Class II page). HCFC-22 was historically the most widely used HCFC, usually as a refrigerant (EPA Class II page). The Class II page lists HCFC-22 in unitary air conditioners, cold storage, retail food cooling equipment, chillers, and industrial process cooling (EPA Class II page). HCFC-22 is also a component in some refrigerant blends, and those blends are subject to the same rules (EPA Class II page).

Production and import versus use

The brochure says EPA is phasing out making R-22, not using it (EPA brochure). The technician FAQ says technicians can tell customers that using existing appliances that contain HCFC-22 is not banned (EPA technician FAQ). The same FAQ says technicians can tell customers there is no EPA mandate to convert existing HCFC-22 equipment (EPA technician FAQ). The brochure says the phaseout period leaves time to switch refrigerants at the usual time for replacing an air conditioner (EPA brochure). According to the brochure, R-22 is still available to service equipment made before 2010 (EPA brochure).

Supply and cost after 2020

After 2020 the brochure says only recovered, recycled, or reclaimed R-22 will be available (EPA brochure). The technician FAQ says EPA expects reclaimed and earlier-produced HCFC-22 to remain available for servicing after 2020, and that the price and availability may change (EPA technician FAQ). The brochure says R-22 will get scarcer, and that servicing an R-22 unit may cost more over time (EPA brochure). Servicing includes replacing failed components, the technician FAQ says (EPA technician FAQ). The FAQ says recovered refrigerant may not go to a new owner as a refrigerant until a reclaimer holding EPA certification has reclaimed it (EPA technician FAQ).

Servicing an R-22 system

The brochure says service on R-22 equipment must be done by a technician holding EPA Section 608 certification (EPA brochure). The brochure says the most important thing a homeowner can do is to maintain the unit properly, and that proper servicing limits possible environmental damage and maintenance costs (EPA brochure). It asks owners to request that technicians locate and repair leaks rather than top off a leaking system (EPA brochure). The brochure says selecting a reliable service contractor is important (EPA brochure). It also says intentionally releasing any refrigerant during repairs is illegal, and that technicians must use recovery equipment during service (EPA brochure).

Disposal of R-22 equipment

The technician FAQ says that for equipment usually taken apart on site, such as central air conditioners, the refrigerant must be recovered under EPA servicing rules before disposal (EPA technician FAQ). Equipment that typically goes to disposal with the charge still in it, such as room air conditioners and household refrigerators, must have the refrigerant recovered by the final person in the disposal chain (EPA technician FAQ). The FAQ says those who handle the equipment ahead of the final person may also have the refrigerant removed, provided they give the final person documentation of the removal (EPA technician FAQ).

New equipment and alternatives

The brochure says systems using alternative refrigerants are available and will become more common (EPA brochure). It names R-410A as the most common alternative to R-22, an HFC blend that does not deplete ozone (EPA brochure). EPA reviews alternatives and keeps a list of substitutes it accepts for household and light commercial cooling (EPA brochure). The technician FAQ warns that some substitutes cannot be used in retrofits (EPA technician FAQ). The Class II page says EPA keeps assessing substitutes for HCFCs under the SNAP program (EPA Class II page).

Why R-22 is being phased out

R-22 is an ozone-depleting substance subject to phaseout under the Montreal Protocol (EPA GreenChill). The brochure says releases of HCFCs deplete the ozone layer and contribute to climate change (EPA brochure). The Class II page says HCFCs were developed as transitional substitutes for CFCs and have a later phaseout schedule than the CFCs (EPA Class II page).

Frequently asked

Can I keep using my R-22 air conditioner?

Yes. The technician FAQ says technicians can tell customers that using existing HCFC-22 appliances is not banned (EPA technician FAQ). The brochure adds that you do not have to replace existing equipment (EPA brochure).

Can R-22 still be serviced after 2020?

Yes. The technician FAQ says existing equipment can be serviced with R-22, and servicing includes replacing failed components (EPA technician FAQ). After 2020, the brochure says only recovered, recycled, or reclaimed R-22 will be available (EPA brochure).

Can a new air conditioner still be made with R-22?

No. The brochure says EPA prohibits manufacturing new air conditioners that use R-22 (EPA brochure). The brochure names R-410A as the most common alternative to R-22 (EPA brochure).

Does the 2020 date mean I have to replace my system?

No. The brochure says you are not required to replace existing equipment (EPA brochure). It says the phaseout period leaves time to switch refrigerants when you would normally replace an air conditioner (EPA brochure).

Do I need to call a pro for this?

Maybe. Refrigerant work on an R-22 system belongs to a licensed contractor. The brochure says technicians must hold EPA Section 608 certification to work on R-22 equipment (EPA brochure). You can check the air filter and thermostat settings yourself, but leave the refrigerant side to a licensed contractor.

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: EPA GreenChill regulatory context, https://www.epa.gov/greenchill/greenchill-regulatory-context · EPA technicians and contractors frequent questions, https://www.epa.gov/ods-phaseout/technicians-and-contractors-frequent-questions · EPA phaseout of Class II ozone-depleting substances, https://www.epa.gov/ods-phaseout/phaseout-class-ii-ozone-depleting-substances · EPA brochure Phasing Out HCFC Refrigerants to Protect the Ozone Layer, https://www.epa.gov/sites/default/files/2015-07/documents/phasing_out_hcfc_refrigerants_to_protect_the_ozone_layer.pdf

Search Google for when was r22 phased out