What Is the New Refrigerant for Air Conditioners?

Newer home air conditioners are moving to lower-GWP refrigerants, and Lennox names R-454B and R-32 for its new lineup (Lennox). Lennox says R-454B goes in its whole-home ducted systems and R-32 in its ductless systems (Lennox), and Carrier describes R-454B as a lower-GWP option, designed as the successor to R-410A for home and light commercial equipment (Carrier). Under EPA's rule, a new residential split air conditioning system put in after January 1, 2026 must use a refrigerant whose GWP is under 700 (EPA).

EPA's subsector for residential and light commercial cooling and heat pump gear takes in units serving single rooms, single-family houses and small commercial buildings (EPA). EPA also says its rule restricts new products and systems from entering the market or operation, and does not limit existing ones (EPA).

The limit for new systems

The rule says that if a whole new system is installed after January 1, 2026, it must use lower-GWP refrigerant (EPA). A new residential split system put in after that date must run on refrigerant with a GWP below 700 (EPA). Under EPA's definition, a system counts as new when it goes into a newly constructed home, or if both the condensing unit and the indoor coil are replaced at the same time (EPA). EPA says that when all the other components are replaced, the work counts as a new system under the Technology Transitions Program, even if the refrigerant lines are kept (EPA). Mini-split air conditioners are listed as one example of a system (EPA).

Dates behind the limit

On December 26, 2023, EPA issued an interim final rule that extended the install window for higher-GWP HFC equipment made or imported before January 1, 2025, to January 1, 2026 (EPA). The interim rule covered residential heat pump and air conditioning systems (EPA).

If you already have a system

EPA says you can keep using an existing air conditioner, and the 2023 Technology Transitions rule places no limit on existing products or systems (EPA). EPA says you can continue to repair an existing air conditioner, and a repair can include replacing a major component such as the condensing unit or the compressor (EPA). Refrigerant and component work is licensed contractor work. Lennox says an existing R-410A system can stay in service, even though it is not cross-compatible with the newer refrigerants (Lennox). EPA adds that supply of HFCs and components may shrink over time while HFCs are phased down (EPA).

R-410A parts and repairs

EPA says a faulty component on an existing R-410A system can be replaced with a similar R-410A component (EPA). Condensing units, indoor coils and other parts that use R-410A may still be sold for servicing legacy R-410A systems (EPA), while R-410A components cannot be used to put in a new R-410A system from January 1, 2026 on (EPA). EPA says that the 2023 Technology Transitions Rule leaves open whether a broken R-410A condensing unit can be replaced with a unit using a lower-GWP refrigerant, which may be possible depending on the situation (EPA). EPA also notes that engineering and design considerations, such as pressures, may rule out some non-flammable refrigerants (EPA).

Why a refrigerant swap is restricted

EPA says its Significant New Alternatives Policy, or SNAP, along with industry standards, bars flammable or mildly flammable refrigerants, like HFC-32 or R-454B, from systems not designed for them (EPA). Carrier says R-454B systems carry equipment and safety features made for that refrigerant (Carrier). Carrier also says R-454B cannot serve as a straight swap for R-410A in equipment already in place (Carrier).

What Carrier says about R-454B

Carrier says Puron Advance, its R-454B product, combines R-32 with R-1234yf (Carrier). Carrier gives a GWP of 466 for R-454B and a GWP of 2,088 for R-410A (Carrier). Carrier also notes that R-454B runs at pressures close to R-410A's, yet it does not work as a drop-in replacement (Carrier). Carrier says R-32 and R-290 have also been used or tested in various applications, and that refrigerant choice weighs GWP, flammability class, efficiency, system design, safety rules and regulatory rules (Carrier).

Room air conditioners

Among room air conditioners, ENERGY STAR points to R-290, R-454B and R-32 (HFC-32) as lower-GWP refrigerants (ENERGY STAR). ENERGY STAR explains that GWP compares a substance's warming power with an equivalent amount of CO2, which has a GWP of 1 (ENERGY STAR). It also says R-32 and R-454B are HFCs that still count as lower-GWP choices among room units (ENERGY STAR).

Research on mini-split units

ORNL's interim report describes a test program on lower-GWP substitutes for R-22 and R-410A in mini-split units at high ambient temperatures (ORNL). The report describes its results as preliminary (ORNL).

Who services R-454B equipment

Carrier says an HVAC professional who knows A2L equipment and the rules that apply to it should install and service R-454B units (Carrier).

Frequently asked

What refrigerant does a new split system need?

Under EPA's rule, a residential split system put in after January 1, 2026 must run on refrigerant with a GWP below 700 (EPA). Systems installed before January 1, 2026 are not covered by that GWP limit (EPA).

Can I keep running my current air conditioner?

Yes. EPA says the rule does not limit the use of an existing air conditioner (EPA). Lennox says an existing R-410A system can stay in service, but it is not cross-compatible with the newer refrigerants (Lennox).

Can a faulty part be replaced on an R-410A system?

EPA says a faulty part on an existing R-410A system can be replaced with a similar R-410A part (EPA). Replacing system parts is licensed contractor work.

What counts as a new system?

A system installed in a newly constructed home counts as new (EPA). EPA also says replacing all the other components counts as a new system under the Technology Transitions Program, even if the refrigerant lines stay in place (EPA).

Do I need to call a pro for this?

Maybe. The homeowner checks are the air filter, thermostat settings, and keeping things clear of the vents, returns and outdoor unit. Any refrigerant, electrical, gas, combustion or venting work needs a licensed contractor. Carrier says an HVAC professional who knows A2L equipment should install and service R-454B units (Carrier).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: EPA, Frequent Questions on the Phasedown of Hydrofluorocarbons, https://www.epa.gov/hfcs/frequent-questions-phasedown-hydrofluorocarbons · ENERGY STAR, Room Air Conditioners, https://www.energystar.gov/products/room_air_conditioners · Lennox, Homeowner's Guide to the New Refrigerant Transition, https://www.lennox.com/residential/lennox-life/consumer/new-hvac-refrigerant-2025 · Carrier, What Is R-454B Refrigerant?, https://www.carrier.com/us/en/residential/hvac-resources/r-454b-refrigerant/ · Oak Ridge National Laboratory, Interim report on mini-split refrigerant testing, https://info.ornl.gov/sites/publications/files/Pub56749.pdf