Carrier says the usual causes of a frozen outdoor unit are restricted airflow, low refrigerant levels, and runoff water that freezes on the coil (Carrier). Lennox says when the defrost timer, board, or sensor fails, ice stops melting and piles up (Lennox).
Trane says the outdoor coil in winter runs typically 10-20°F colder than outdoor air (Trane). Trane says condensation on that coil freezes once the outdoor temperature is low enough (Trane).
Why the outdoor coil frosts
Trane says the outdoor coil gathers condensation the way a cold glass does (Trane). Trane says a heat pump can enter defrost with outdoor air in the low 40s, and that this is more common when it is in the 20s or 30s (Trane). American Standard says a defrost cycle is needed when cold, humid conditions build frost or ice on the outdoor coil, and calls it a normal process that may release a cloud of steam (American Standard). Carrier says frost generally less than 1/4 inch thick is normal and clears when the unit runs its automatic defrost (Carrier).
How defrost works, and how long it takes
Trane says a reversing valve switches the refrigerant direction so the outdoor coil warms, and the system runs in cooling mode for a few minutes (Trane). American Standard says the heat pump returns to an energy-efficient heat mode once the ice melts (American Standard). Carrier gives about 5 to 10 minutes as the typical length of a defrost cycle (Carrier). Lennox says the unit should run a defrost automatically every 30 to 90 minutes (Lennox). Carrier says heavy ice that remains after the cycle, or defrosting that happens unusually often, calls for a professional inspection (Carrier).
Airflow, filters and blocked vents
Lennox says restricted airflow makes the coils run too cold, and ice builds up on them (Lennox). Lennox lists dirty or clogged air filters, collapsed or blocked ductwork, and closed or blocked supply vents among airflow problems (Lennox). Trane says a dirty filter restricts airflow, and that can end in a frozen evaporator coil (Trane). Trane says filters should be changed every 30 to 90 days, depending on filter quality, how hard the system runs, and whether pets are in the home (Trane). Trane says blocked return vents give the coil too little airflow, and a couch or other furniture in front of a return is a common issue (Trane).
Debris, drainage and weather at the outdoor unit
Carrier says a blocked outdoor coil can lose efficiency when cottonwood or leaves collect on it (Carrier). Carrier says to check the outdoor unit for leaves or snow and remove any blockage (Carrier). Carrier says meltwater from snow or ice can run onto the coil and refreeze there, and that the defrost mode may fall short when the coil is severely iced (Carrier). Lennox says water can pool around the unit when a drain pan or line clogs, and then it refreezes (Lennox). Lennox says long spells of icy rain, sleet, or heavy wet snow can overpower the defrost system (Lennox).
Refrigerant leaks and indoor coil causes
Lennox says a leak that drops refrigerant levels makes the coils run very cold, and ice forms fast (Lennox). Carrier says a low refrigerant charge can leave the system unable to make enough heat to melt winter ice (Carrier). Refrigerant work belongs to a licensed contractor, and Carrier says charge testing requires a qualified technician (Carrier). Trane says to call an HVAC professional right away for oily residue near the indoor coil or a hissing sound near either coil (Trane). Trane lists five causes that can lead to a frozen indoor evaporator coil: a dirty filter, a dirty coil, blocked return vents, a faulty thermostat, and a refrigerant leak or low refrigerant (Trane). Trane says coils frozen only in the morning may point to the thermostat, if it does not shut the unit down as overnight temperatures fall (Trane). Trane says the outdoor coil of an AC is unlikely to freeze in summer, though a heat pump's outdoor coil can freeze while heating (Trane).
What a homeowner can check, and what not to do
Trane says to switch the thermostat from Cool to Off and let the coil thaw (Trane). Trane says do not put a heat pump into defrost mode while its indoor coil is frozen (Trane). Trane says defrost mode only removes ice from the outdoor coil, which can build up while the heat pump is heating the house (Trane). Trane says setting the thermostat fan to On instead of Auto can speed the thaw, which may take a few hours (Trane). Trane says do not chip away at the ice, since that can damage the coil and lead to a refrigerant leak (Trane). Carrier says never chip at ice on the coil (Carrier). Lennox says tools used on ice can damage the coil fins and fan blades (Lennox). Trane says to keep the system off until the coil thaws and the filter has been changed (Trane). Trane says running on a frozen coil harms the outdoor compressor, which is very expensive to replace (Trane).
When to call a professional
Carrier says to turn the system off and contact a qualified HVAC professional if ice grows past 1/4 inch or stays after the defrost run (Carrier). Lennox says a unit that refreezes soon after thawing may have a refrigerant leak, an airflow problem, or a defrost control fault (Lennox). Lennox says a trained HVAC technician can find faulty defrost controls, reversing valve problems, or sensor faults behind repeated freezing (Lennox). Lennox says ice that has not melted within 6-8 hours, or a unit that refreezes quickly, means calling a technician (Lennox). American Standard says to call for help if the heat pump keeps switching into defrost, the cycles grow longer, and ice and frost cover the unit (American Standard).
Frequently asked
Is frost on a heat pump normal?
Light frost is normal in cold, humid weather (Lennox). Carrier says ice buildup thicker than 1/4 inch is not normal and requires attention (Carrier).
Do I need to call a pro for this?
Yes, if ice grows past 1/4 inch or stays after a defrost run, Carrier says to turn the system off and contact a qualified HVAC professional (Carrier). Refrigerant and electrical repairs go to a licensed contractor, and Carrier says complex problems in those areas need a professional (Carrier). Homeowner checks are limited to the air filter, thermostat settings, keeping debris away from the outdoor unit, and keeping the return and supply vents clear (Trane; Lennox).
How long does a defrost cycle last?
Carrier gives about 5 to 10 minutes as the typical length of a defrost cycle (Carrier). Trane says the cycle puts the heat pump in cooling mode for a few minutes (Trane). Lennox says a frozen unit should thaw within 2 to 4 hours when temperatures are above freezing (Lennox).
Can I run my AC or heat pump with a frozen coil?
Trane says running with a frozen coil may cause irreparable harm to the cooling system (Trane). Trane says to keep the system off until the coil thaws and the filter is changed (Trane).
What does ice on the refrigerant lines mean?
Lennox says ice on the refrigerant lines, indoors or outdoors, is a reason to call a professional (Lennox). Trane says icing on the refrigerant lines may have the same culprits as a frozen outdoor coil (Trane).
Related
- Heat Pump Defrost Mode: What It Is and What Is Normal
- The Evaporator Coil: Function, Cleaning and Problems
- AC Refrigerant Leak Repair: Find-and-Fix vs Top-Off
- AC Filter Replacement: Which Filter to Buy and How Often to Change It
Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.
Sources: Trane, What Is a Heat Pump Defrost Cycle?, https://www.trane.com/residential/en/resources/blog/what-is-heat-pump-defrost-cycle/ · American Standard, What Is a Heat Pump Defrost Cycle?, https://www.americanstandardair.com/resources/blog/what-is-heat-pump-defrost-cycle/ · Carrier, Heat Pump Troubleshooting, https://www.carrier.com/us/en/residential/hvac-resources/heat-pumps/heat-pump-troubleshooting/ · Carrier, Heat Pump Not Heating, https://www.carrier.com/us/en/residential/hvac-resources/heat-pumps/heat-pump-not-heating/ · Lennox, What to Do If Your Heat Pump Is Frozen?, https://www.lennox.com/residential/lennox-life/consumer/heat-pump-frozen · Trane, Top 5 Causes of Frozen AC Coils and How to Fix Them, https://www.trane.com/residential/en/resources/blog/frozen-evaporator-coil-causes/