Ducts that sweat: moisture and condensation

EPA says moisture can enter a duct system through leaks or improper installation or service (EPA). EPA says condensation may form when warm, humid air contacts a cold surface (EPA). Research suggests condensation on or near air conditioner cooling coils is a major factor in moisture contamination of the system (EPA).

Condensation occurs when a surface temperature is lower than the dew point temperature of the surrounding air (EPA). The sections below cover how moisture gets into ducts, where condensation forms, how sealing and insulation fit in, and how mold, drip pans and cleaning are handled. Each fact cites its source.

How moisture enters the duct system

Moisture can enter a duct system through leaks or through improper installation or service (EPA).

ENERGY STAR says the connections where vents and registers meet floors, walls and ceilings should be well-sealed (ENERGY STAR). ENERGY STAR also says these register and vent connections are common locations for leaks and disconnected ductwork (ENERGY STAR).

Look at the edge of each register for gaps, and ask a licensed contractor to check any joint you cannot reach.

Condensation forms on cold surfaces

EPA says condensation may form when warm, humid air contacts a cold surface (EPA). Research suggests condensation on or near air conditioner cooling coils is a major factor in moisture contamination of the system (EPA).

If the system shows moisture, ask a licensed contractor to inspect the cooling coil area and the drip pan. Ask them to confirm which part of the system the moisture comes from.

Seal and insulate ducts in attics and crawl spaces

EPA says ducts should be properly sealed and insulated in all non-air-conditioned spaces, such as attics and crawl spaces (EPA). ENERGY STAR says ducts are often hidden in walls, ceilings, attics and basements, which can make repairs difficult (ENERGY STAR).

A 1995 FSEC publication says leaky duct systems cause increased infiltration of humid attic air into the conditioned space (FSEC). The same publication says condensation problems in attics have been reported in humid southern climates (FSEC).

ENERGY STAR says duct tape should not be used to seal ducts because it does not last (ENERGY STAR). Ask a licensed contractor which sealing method they plan to use for any gap they find.

Controlling moisture is the most effective way to prevent mold in ducts

EPA says controlling moisture is the most effective way to prevent biological growth in air ducts (EPA). EPA also says controlling moisture is the most effective way of keeping mold from growing in air ducts (EPA).

EPA says the HVAC system should not be run if you know or suspect that it is contaminated with mold (EPA). EPA also says conventional HVAC filters are typically not effective in filtering particles the size of mold spores (EPA).

EPA says heavy mold growth on ceiling tiles may impact HVAC systems if the space above the ceiling is used as a return air plenum (EPA). Ask a licensed contractor whether the space above a ceiling vent is used as a return plenum.

Drip pans and moisture-based duct cleaning

EPA says HVAC drip pans should be kept clean, flowing properly and unobstructed (EPA). EPA says steam cleaning and other methods involving moisture should not be used on any kind of duct work (EPA).

When a technician services the system, ask them to check the drip pan and its drain line. Before a duct cleaning visit, ask the company which cleaning method it uses.

Attic air, dew point and interior moisture

FSEC says attic air holds more moisture when its temperature is higher (FSEC). FSEC also says a raised dew point in the attic can drive moisture into the conditioned space by vapor pressure differences (FSEC). The same publication says high interior moisture levels have been reported to drop when attic ventilation is curtailed (FSEC).

The National Weather Service defines dew point as the temperature at which condensation, either dew or frost, occurs (NWS). It describes dew point as a relationship between relative humidity and air temperature (NWS).

Ask a licensed contractor before you change attic ventilation.

When to call a licensed contractor

If you see water near a duct, register or drip pan, call a licensed contractor to inspect the seals, insulation and drip pan. Write down where the water appears and the date you first saw it, so the technician has a record.

Frequently asked

How does moisture get into air ducts?

Moisture can enter the duct system through leaks or if the system has been improperly installed or serviced (EPA). Ask a licensed contractor to check the joints for leaks.

Why does condensation form on cold surfaces?

EPA says condensation may form when warm, humid air contacts a cold surface (EPA).

Do ducts in an attic need insulation?

EPA says ducts should be properly sealed and insulated in all non-air-conditioned spaces, such as attics and crawl spaces (EPA).

Is duct tape enough to seal ducts?

ENERGY STAR says duct tape should not be used to seal ducts because it does not last (ENERGY STAR).

Can ducts be steam cleaned?

EPA says steam cleaning and other methods involving moisture should not be used on any kind of duct work (EPA).

What is dew point?

The National Weather Service defines dew point as the temperature at which condensation, either dew or frost, occurs (NWS).

Related

Seeing moisture near your ducts or cooling equipment? Blume Mechanical Service (license CAC-1822618) repairs, installs and maintains HVAC equipment and is brand-agnostic. Serving Pinellas, Hillsborough and Pasco counties, call 727-330-9131.

Sources: U.S. EPA — Should You Have the Air Ducts in Your Home Cleaned? (https://www.epa.gov/indoor-air-quality-iaq/should-you-have-air-ducts-your-home-cleaned) · U.S. EPA — Mold Course Chapter 2 (https://www.epa.gov/mold/mold-course-chapter-2) · U.S. EPA — Mold Course Chapter 9 (https://www.epa.gov/mold/mold-course-chapter-9) · U.S. EPA — Mold Remediation in Schools and Commercial Buildings Guide: Chapter 3 (https://www.epa.gov/mold/mold-remediation-schools-and-commercial-buildings-guide-chapter-3) · ENERGY STAR — Duct Sealing (https://www.energystar.gov/saveathome/heating-cooling/duct-sealing) · Florida Solar Energy Center — FSEC-PF-408-95 (https://fsec.ucf.edu/en/publications/html/FSEC-PF-408-95/) · National Weather Service — Mesoscale Analysis - Info (https://weather.gov/mfl/analysisinfo)

Search Google for why do my ducts sweat