Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

How a return air filter is sized, placed and changed

The DOE EERE guide checks a filter's size through filter velocity, calculated as tons multiplied by 57,600 and divided by the filter's length times width in inches, and it treats 300 fpm or less as the general limit (EERE). EPA's technical guide says a return-grille filter, unlike one at the air-handling unit, can have less overall effect on airflow resistance, and EPA's consumer guide says manufacturers typically advise a change every 60 to 90 days (EPA technical guide; EPA).

EPA says upgrading a furnace or central HVAC filter can help indoor air quality (EPA). EPA also says HVAC filters can reduce indoor air pollution but cannot remove every pollutant from the air (EPA).

Sizing the filter by velocity

The EERE air conditioner diagnostics guide gives the filter velocity formula as tons times 57,600 divided by the filter's length times width, with length and width in inches (EERE). Tons means the air conditioner's rated tons (EERE). The guide's general rule is a velocity of 300 fpm or less, which it gives as a way to keep pressure loss from getting excessive (EERE). The guide also says that above 300 fpm, high-efficiency filters are nearly certain to lower airflow to levels it calls unacceptable (EERE). The guide cites ACCA Manual D as suggesting about 0.10 in. w.c. of pressure drop for a clean standard furnace filter (EERE). In its example, the "best MERV 8 filter" would need a velocity of about 220 fpm to reach 0.10 in. w.c., and a 2-ton system at 800 cfm would need a filter about 20 in. x 25 in. to hold that velocity (EERE).

Existing grilles and filter slots

According to the EERE guide, the grilles and furnace filter slots in most existing HVAC systems were sized around fiberglass filters (EERE). The guide adds that the usual move is to swap in higher-MERV filters, which remove small particles such as pollen more effectively (EERE). Those filters restrict airflow much more, which lowers airflow with PSC blower motors or raises power use with variable speed blower motors, or both (EERE). The guide says that when equipment is replaced, duct sizing and tightness, and above all the filter grille's size, should be evaluated and upgraded where needed (EERE).

Where the filter sits at the return

EPA's technical guide says a return-grille filter, unlike one at the air-handling unit, can have less overall effect on airflow resistance, and such filters can often be larger in area (EPA technical guide). Frames that are designed or installed incorrectly can let air bypass the filter, which greatly reduces how well it works (EPA technical guide). Return duct leakage can also cause bypass: air from unconditioned spaces that enters the return duct can get around a filter at a return grille (EPA technical guide). The guide recommends that ducts be sealed well when filters sit at return grilles (EPA technical guide).

New installs and existing homes

For new installations, the guide says the manufacturer's information should be checked to see whether high-efficiency filters with a high pressure drop are feasible, given the design and the supply and return duct velocities (EPA technical guide). In existing homes, the entire installed system can be measured to confirm it can handle the extra pressure drop a high-efficiency air filter adds (EPA technical guide). The guide says high-efficiency filters require frames that seal well to stop leaks (EPA technical guide).

Changing the filter

EPA's consumer guide says all filters need regular replacement (EPA). It says a dirty, overloaded filter will not work well (EPA). EPA says to follow the manufacturer's recommendations, and that manufacturers typically call for a change every 60 to 90 days (EPA). If a filter looks heavily soiled when swapped out, EPA says to consider changing it more often (EPA). EPA notes a furnace or HVAC filter cleans air only while the system runs (EPA). The DOE Energy Saver guide lists "Clean or replace filters on furnaces" (DOE Energy Saver). For air conditioners, the same guide says to "Clean or replace filters on air conditioners once a month or as recommended" (DOE Energy Saver).

Choosing a higher-rated filter

EPA advises a filter rated MERV 13 or higher, as high as the system can accept (EPA). EPA says most systems can take a MERV 13 filter without equipment problems, provided it is replaced often (EPA). EPA says to pick the highest rating that the system fan and filter slot can take (EPA). EPA adds that it may be hard to tell if a system can take a higher-efficiency filter, and says to consult a professional HVAC technician to be certain (EPA).

Fit and size

EPA says filters commonly come in 1 to 5 inch thicknesses, in a range of lengths and widths matched to common frame sizes (EPA). EPA says a filter should fit snugly, with no air leaking around it, and should not have to be bent or crushed to fit (EPA).

Frequently asked

How do I know what size filter to buy?

Filters are commonly sold in thicknesses of 1 to 5 inches, in lengths and widths matched to common frame sizes (EPA). The EERE filter velocity formula uses the filter's length and width in inches (EERE).

How often should I change the filter?

EPA says to follow the manufacturer's recommendations, which typically call for a change every 60 to 90 days (EPA). The DOE Energy Saver guide says to "Clean or replace filters on air conditioners once a month or as recommended" (DOE Energy Saver).

Can I use a higher-rated filter in my return?

EPA says most systems can take a MERV 13 filter without equipment problems, provided it is replaced often (EPA). The EERE guide says higher-MERV filters restrict airflow much more (EERE). EPA says a professional HVAC technician may help identify the highest-efficiency filter a system can use (EPA).

Does it matter where the filter sits at the return?

EPA's technical guide says a return-grille filter, unlike one at the air-handling unit, can have less overall effect on airflow resistance (EPA technical guide). It also says air from unconditioned spaces can get around a return-grille filter through return duct leakage, and recommends sealing ducts well for return grille installations (EPA technical guide).

Do I need to call a pro for this?

Maybe. Checking and changing the air filter is a homeowner check, but EPA says a professional HVAC technician may be needed to pick the highest-efficiency filter a system can use (EPA). Work on refrigerant, electrical, gas, combustion or venting is for a licensed contractor.

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: EPA, Guide to Air Cleaners in the Home, https://www.epa.gov/indoor-air-quality-iaq/guide-air-cleaners-home · EPA, Residential Air Cleaners: A Technical Summary, 3rd edition, https://www.epa.gov/sites/default/files/2018-07/documents/residential_air_cleaners_-_a_technical_summary_3rd_edition.pdf · U.S. DOE EERE, Measure Guide: Air Conditioning Diagnostics, https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/measure_guide_air_cond_diagnostics.pdf · U.S. DOE, Energy Saver Guide (2022), https://www.energy.gov/sites/default/files/2022-08/energy-saver-guide-2022.pdf

Search Google for cold air return filter