How do apartment HVAC systems work? Unit types explained

Decentralized systems are installed in apartments, and they can be one or more separate HVAC units that each carry their own refrigeration cycle (ASHRAE). For apartments, the handbook describes through-the-wall room units and PTACs (ASHRAE). A PTAC is a wall sleeve paired with a separate, unencased set of heating and cooling assemblies made for mounting through the wall (ASHRAE). In cooling mode, a typical room air conditioner moves heat with a refrigerant cycle: heat from indoor air turns the refrigerant to vapor in the evaporator, a compressor raises the vapor's temperature, the condenser gives that heat to outdoor air, and a restrictor drops its pressure before it returns to the evaporator (ASHRAE).

Apartment heating and cooling can come from several kinds of equipment. Two ASHRAE handbook chapters describe decentralized systems, window and through-the-wall room units, and packaged terminal air conditioners (PTACs), along with the power, structure, energy and sound each one involves (ASHRAE). The label on your own unit and its owner documents give the specifics for that unit.

What decentralized means

The handbook says decentralized systems can be one or more separate HVAC units. Each unit has an integral refrigeration cycle, a heating source, and outdoor air ventilation, direct or indirect (ASHRAE). Fans, filters, a heating source, a cooling coil, one or more refrigerant compressors, controls and a condenser are designed at the factory and combined into one package (ASHRAE).

Although decentralized systems are often grouped with packaged units, many of them are far from being one packaged unit (ASHRAE). The handbook says they can be found in nearly every class of building (ASHRAE). Packaged units for perimeter spaces are often paired with an all-air central system or a floor-by-floor system. Such pairings can give better humidity control, air cleanliness and ventilation than packaged units working alone (ASHRAE).

Where apartments fit

The handbook lists apartments among the multiple-occupancy dwellings where decentralized systems are installed (ASHRAE). The same list covers offices, shopping centers, factories, schools, health care facilities, hotels and motels, nursing homes and other multiple-occupancy dwellings (ASHRAE).

Systems built from several single units are favored in low-rise offices, factories, shopping centers, department stores and apartment blocks (ASHRAE).

Check the equipment in your own unit to see which system it uses.

Space, power and structure

Every decentralized unit needs electricity, gas or both at the place where it sits (ASHRAE). The building structure has to carry decentralized packaged equipment, since a typical full compressorized package is heavier than an air-handling-only system of similar size (ASHRAE). The handbook notes that decentralized equipment offers limited capacity diversity, since every unit has to be sized to meet its own peak load (ASHRAE).

These are design points for the building. A structural or utility check belongs to a licensed contractor or the building owner.

If you are planning a change to the equipment, bring the room sizes, the electrical service and the building's construction details to the first visit so the contractor can plan the work.

Energy use and sound

The handbook says energy use is usually greater than with central systems if the unitary equipment is less efficient than the combined central components (ASHRAE). Another energy point: equipment in vacant areas can be switched off at the unit or from a central location, with occupied areas not affected (ASHRAE).

Operating sound can be high, and noise-producing machinery often sits nearer building occupants than it does in central systems (ASHRAE).

Ask the owner or installer for the efficiency data of the equipment before you compare it with a central system. Ask where the noisy part of the unit sits relative to your bedroom.

Window and through-the-wall room units

The handbook says window air conditioners and through-the-wall room units with supplemental heating are built to cool or heat individual rooms (ASHRAE). Sleeve-mounted versions are a popular pick for low-cost apartments, motels and homes (ASHRAE).

Through-the-wall mounts are used to install window-type chassis, whole units or consoles in apartment buildings, hotels, motels and homes (ASHRAE). Through-the-wall models have no side louvers; their condenser air enters at the outdoor end of the unit (ASHRAE). The handbook says manufacturers expect through-the-wall units to last 10 to 15 years with proper maintenance (ASHRAE).

PTAC units

Federal regulation and AHRI define a PTAC as a wall sleeve with a separate, unencased set of heating and cooling assemblies for mounting through the wall (ASHRAE). Its parts include refrigeration components, outdoor louvers that can be removed, forced ventilation, and a heating system that uses hot water, steam or electric resistance (ASHRAE).

The ASHRAE handbook gives PTAC cooling capacity as "typically 6000 to 18,000 Btu/h," with heating output at comparable levels (ASHRAE).

PTACs are mostly used in fairly small zones along a building's perimeter, and apartments are among those buildings (ASHRAE). Generally, a gas-fired PTAC costs more to install but usually costs less to run in heating mode (ASHRAE). When a gas-fired PTAC is compared with an electric-resistance PTAC or a PTHP, the handbook suggests weighing both operating and installation costs, and it recommends a life-cycle cost comparison (ASHRAE). The handbook describes advanced master controls at a central location that let an operator override the occupant's control settings, and says they may restrict operation past certain room temperature limits, shift set points during unoccupied hours, and shut off some units to cut peak electrical demand (ASHRAE).

Zoning, appearance and sound

The handbook names zoning as one main advantage of the PTAC and PTHP concept (ASHRAE). Because PTAC units sit inside the conditioned space, the handbook treats both appearance and sound level as important considerations (ASHRAE). Ducting sound attenuation cannot be had on free-discharge PTAC units (ASHRAE).

When you compare a unit in a rental, ask which room it would serve and where its sound would be heard most. Write down the answers so the owner can confirm them in writing.

Questions to ask and who to call

Ask the owner or property manager which type of unit serves your space, such as a window unit, a through-the-wall unit or a PTAC. Ask who services the equipment and who to call when it stops heating or cooling. The handbook says many packaged systems can be covered by a service contract with a local firm (ASHRAE). It also says a clogged filter lowers cooling and airflow and often lets frost build up on the cooling coil (ASHRAE).

Blume Mechanical Service (license CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties.

Frequently asked

Are decentralized systems used in apartments?

Yes. Apartments are among the buildings the handbook names for decentralized installations (ASHRAE). Each of those units has its own refrigeration cycle (ASHRAE).

Is a through-the-wall unit the same as a window unit?

Not exactly. The handbook calls through-the-wall models close to window-mounted units, with one difference it names: no side louvers for condenser air (ASHRAE).

Do apartment systems use more energy than central systems?

The handbook says energy use is usually higher than central systems when a unit's efficiency is below that of the combined central components (ASHRAE).

Can a PTAC heat as well as cool?

Yes. A PTAC heats with hot water, steam or electric resistance (ASHRAE). A packaged terminal heat pump (PTHP) is a heat pump version of the PTAC that provides heat by reversing the refrigerant cycle (ASHRAE). Check the labels on your unit to see which heat source it uses.

Why can apartment equipment be loud?

The handbook says a certain amount of sound is expected from air movement and compressor operation (ASHRAE). Excessive outdoor sound from condenser fans and compressors can also bother neighbors (ASHRAE).

Do I need to call a pro for this?

Maybe. Ask who services the equipment and who to call when it stops heating or cooling. Ask the owner or property manager which type of unit serves your space, such as a window unit, a through-the-wall unit or a PTAC. The ASHRAE handbook says a clogged filter lowers cooling and airflow and often lets frost build up on the cooling coil (ASHRAE). Have a licensed contractor do any refrigerant, electrical, gas, combustion or venting work.