What a furnace control board does and the signs it has failed

A furnace control board is the computerized circuit board that controls the furnace, and Carrier calls it "the computer of the operation" that coordinates the furnace's electrical components (Carrier). Carrier says a failing board can let the blower run without heat so the heater blows cold air, and it names several tries to start, frequent burner cycling and erratic running as possible signs (Carrier).

Carrier's cold-air diagnostic lists computerized controls among the areas to check (Carrier). Lennox lines below apply to EL180UHNEK series units only, and Goodman lines apply to the furnaces in the Goodman document, models GMEC80, GCEC80, AMEC80 and ACEC80.

What the control board does

Carrier says modern furnaces run on a computerized circuit board (Carrier). The Carrier parts page says the board sends its signals based on instructions from the thermostat, and it works with the burner, blower motor and fans (Carrier). Carrier says control boards are selected for specific furnace models, and that they should be matched to the unit's requirements (Carrier).

What Lennox and Goodman describe

On Lennox EL180UHNEK series gas furnaces, the single-stage integrated control handles ignition timing, fan-off delays in heating mode, and blower speeds, all based on selections (Lennox). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, power-up lights a red LED while the self-check runs, and standby shows as a slow green flash on the furnace status LED (Goodman).

Signs of a failed control board

Carrier says a failing board may let the blower run without heat, so the heater blows cold air (Carrier). Carrier lists a failing board as a potential cause of several tries to start, frequent burner on-and-off cycling, or other signs of board failure (Carrier). Carrier also says a malfunctioning board can make the furnace run erratically or not start at all (Carrier). Carrier's cold-air page also lists wild temperature swings and a furnace that does not follow its normal startup sequence (inducer motor, ignitor, gas valve) under computerized-control problems (Carrier). Carrier says blinking LED lights on the board are diagnostic codes, and advises noting the pattern and contacting a Carrier expert (Carrier).

Maker-specific codes, each from its own document

On Lennox EL180UHNEK series units, code E163 is listed as Furnace Control Board Failure and may call for a replacement indoor unit control board (Lennox). On Lennox EL180UHNEK series units, the seven-segment diagnostic LED shows error codes, and error code recall gives access to the most recent 10 (Lennox). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, the control displays a three amber flash code when a second-stage call comes without a first-stage call, and stores that code once during a single power cycle (Goodman).

How the Lennox control runs a heating call

On a Lennox EL180UHNEK call for heat, the integrated control watches the inducer pressure switch and does not begin the cycle while that switch is closed (Lennox). After a 15-second pre-purge, the igniter warms up for 20 seconds, and the gas valve opens at the 19-second mark for a 4-second ignition trial (Lennox). If ignition is not proved, the control tries four more times with a 35-second warm-up between trials, and after five trials it enters Watchguard-Flame Failure mode (Lennox). The control starts the ignition sequence again after a 60-minute reset period (Lennox). The Lennox blower-on time is 30 seconds after flame is sensed (Lennox). On Lennox EL180UHNEK units, the integrated control lets the gas valve stay open while it senses a flame signal (Lennox).

Lennox blower timing and flame display

On Lennox EL180UHNEK units, the heat fan-on time is 30 seconds and is not adjustable (Lennox). On Lennox EL180UHNEK units, the blower-off delay is factory set to 120 seconds, and the integrated control's two-position dip switch offers four selections (Lennox). Lennox's flame signal mode shows the flame current in microamps on the seven-segment LED (Lennox).

How the Goodman control runs a heating call

In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, the heat-mode list has the control check the gas valve relay status, verify the high limit switch contacts, and check the low pressure switch for closure before the pre-purge begins (Goodman). After the igniter warm-up, a trial for ignition begins and the first-stage gas valve is turned on (Goodman). The igniter turns off when flame is sensed or when the ignition activation period ends, whichever comes first (Goodman). Once flame is sensed, a heat-on delay starts, and the circulator later runs at low heat speed (Goodman). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, if the call for heat is lost during the trial for ignition without flame, the control turns off the gas valve and igniter, and the post-purge time is increased to 60 seconds (Goodman).

Indicator lights and codes by maker

In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, the amber LED shows a slow flash for normal heat operation (Goodman). Goodman describes a diagnostic flash code for reversed polarity on its PCBBF139 ignition control (Goodman). On Lennox EL180UHNEK series units, the diagnostic push button enables the Error Code Recall mode and the Flame Signal mode, and holding it steps through a menu with a new item every five seconds (Lennox). Recall shows the most recent 10 error codes, and pressing the button a second time confirms a clear of stored codes (Lennox). On Lennox EL180UHNEK series units, E000 means no error in memory (Lennox).

Flame sensor, fuses and voltage checks

In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, in certain conditions the fuel or combustion air can leave a nearly invisible film on the flame sensor, and a qualified servicer must clean it (Goodman). Goodman's service procedure, which is written for a qualified technician, lists an open fuse among the causes of a no-reading result in its voltage check (Goodman). Goodman's technician procedure lists an open fuse among several causes when no voltage is found at its R and C terminals check (Goodman). On Lennox EL180UHNEK units, a 24V circuit breaker, CB8, gives overcurrent protection to the transformer T1 and is rated 3A at 32V (Lennox).

Safety warnings and qualified service

In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, the warning block is headed "ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD" and says "Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death or property damage" (Goodman). Goodman warns that to avoid personal injury or death from electrical shock, the furnace power must be turned off before changing speed taps (Goodman), and says to disconnect all power before servicing (Goodman). For Lennox EL180UHNEK series units, Lennox says to disconnect power before servicing, and that the control is "not field repairable"; if it is inoperable, the entire control is replaced (Lennox). Goodman's wiring warning says that to avoid "the risk of electrical shock", wiring to the unit "must be properly polarized and grounded" (Goodman).

When to stop and call a professional

Carrier says to remove the cabinet door only if the owner's manual specifically permits homeowner access (Carrier), and says the owner must not try to repair or replace the board (Carrier). Carrier says: "Do not attempt to repair or replace the control board yourself" and that furnace electrical and combustion components "should be serviced by a qualified professional" (Carrier). Carrier says electrical components and safety controls "should be handled by a qualified HVAC professional" (Carrier). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, Goodman says products "should be serviced only by a qualified service technician" (Goodman), and that installation and service "must be performed by a qualified installer, service agency or the gas supplier" (Goodman).

Frequently asked

What does the control board do during a heating call?

On Lennox EL180UHNEK units, the integrated control runs a 15-second pre-purge, a 20-second igniter warm-up, and opens the gas valve at the 19-second mark (Lennox). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, the first-stage gas valve is energized when the trial for ignition begins, and the circulator fan runs at low heat speed after the delay to heat on (Goodman).

What does a displayed or flashing code mean?

In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, a call for second stage without a call for first stage shows a three amber flash code (Goodman). On Lennox EL180UHNEK series units, the seven-segment LED shows error codes, and E163 is listed as Furnace Control Board Failure (Lennox).

Can a homeowner replace the control board?

Carrier says "Do not attempt to repair or replace the control board yourself," and that furnace electrical and combustion components "should be serviced by a qualified professional" (Carrier). For Lennox EL180UHNEK series units, Lennox says the control is "not field repairable" and that an inoperable control is replaced as a whole (Lennox). In the Goodman document for GMEC80, GCEC80, AMEC80 and ACEC80 furnaces, Goodman says its products "should be serviced only by a qualified service technician" (Goodman).

How long does the blower keep running after heat stops?

On Lennox EL180UHNEK units, the blower-off delay is set at the factory to 120 seconds, and a two-position dip switch offers four selections (Lennox).

Do I need to call a pro for this?

Yes. Carrier says owners are not to try repairing or replacing the board themselves (Carrier). Carrier notes that a failing board may allow the blower to run with no heat, which leaves the heater blowing cold air (Carrier). A licensed contractor should handle it, because Carrier says a qualified HVAC professional should take on electrical components (Carrier).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: Carrier, Blowing Cold Air: Furnace Troubleshooting, https://www.carrier.com/us/en/residential/hvac-resources/furnaces/furnace-blowing-cold-air/ · Carrier, Furnace Parts: Understanding the Components of a Furnace, https://www.carrier.com/residential/en/us/products/furnaces/furnace-parts/ · Goodman, Furnace literature RS6621005R1, https://mobile.goodmanmfg.com/mobileapp/stellent/pdf/infoPdf/Lit/RS6621005R1.pdf · Lennox, Service Literature 100157, EL180UHNEK with R-454B series units, https://www.lennox.com/dA/608a3158de/100157.pdf