Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

Does Refrigerant Go Bad?

In a sealed system, refrigerant is not used up, so low levels almost always mean a leak (Bryant). Bryant says refrigerant stays sealed in the system and should last for the equipment's whole life (Bryant). Trane says the sealed system keeps reusing its refrigerant in a continuous cycle, and it could go its whole lifespan without an AC recharge (Trane).

Carrier says a home AC should never need a recharge under normal circumstances (Carrier). Carrier says a sealed system that needs one has a physical leak that must be repaired (Carrier). Trane says a frozen evaporator coil, a hissing or bubbling sound close to the refrigerant lines, a unit that runs constantly, and blowing warm air could each be a sign of a leak (Trane).

Why refrigerant stays in the system

Bryant says AC refrigerant absorbs heat from indoor air and releases it outside, and it does this through a closed-loop refrigeration cycle (Bryant). Carrier says an air conditioner does not use up refrigerant the way a car uses gasoline, because the system is closed-loop (Carrier). Trane says a sealed system keeps reusing its refrigerant in a continuous cycle (Trane).

What causes a leak

Trane names everyday wear, skipped maintenance and installation problems as ways a leak can start (Trane). Trane also says a leak makes refrigerant levels drop (Trane). Carrier lists copper corrosion from household chemicals such as hairspray and air fresheners, lines rubbing from vibration, weak joints from the original installation, and physical damage to the outdoor unit as ways leaks form (Carrier).

Signs of a low charge

Carrier says a recharge may be in store when a unit blows warm air, runs constantly without cooling the home, or forms ice on the refrigerant lines (Carrier). Carrier also lists hissing or bubbling noises, unusually high energy bills, and a house that never reaches the thermostat setting as signs (Carrier). Bryant lists hissing or bubbling sounds, frozen evaporator coils, reduced cooling power, and longer run times or higher energy use as the most common signs (Bryant). Carrier's leak page says high indoor humidity can also show up, and that refrigerant helps remove humidity from the air (Carrier).

Topping off does not fix a leak

Carrier calls simply adding more refrigerant a "temporary and often illegal band-aid" (Carrier). Carrier says this can eventually lead to major compressor failure (Carrier). Carrier says the underlying leak must be repaired first (Carrier). Carrier says leak sealants can briefly patch tiny pinholes, but manufacturers generally do not recommend them, since they can block the expansion valve and harm the compressor in the long run (Carrier). Bryant says a leak needs to be found and fixed instead of being refilled again and again (Bryant).

Older refrigerants

Bryant says R-410A replaced the ozone-depleting R-22 as the residential standard, and R-410A equipment can still be serviced (Bryant). Carrier's recharge page says the EPA stopped new R-22 production and import in 2020, while R-22 that has been recovered, recycled or reclaimed can still go into existing equipment (Carrier). Carrier's leak page says R-22 can no longer be made in or brought into the United States to service existing equipment (Carrier).

When repair or replacement makes sense

Carrier says a recharge suits a unit that is less than 10 years old, with a leak that is easy to reach and inexpensive to fix (Carrier). Carrier lists replacement as the better fit for units older than 15 years, for homes still using obsolete R-22 Freon, and for repeated leaks in the indoor evaporator coil (Carrier). Trane says that if you have an R-22 unit made in 2009 or earlier, it is at least 15 years old, and a recharge on it is only needed because of a leak (Trane). Trane says a recharge might hold for just a few days (Trane). Trane also says that when repairs keep growing in number, it may be time to put money into a new system (Trane).

Safety and licensed work

Bryant says leaks can crowd out oxygen in confined spaces, and direct contact may bring on frostbite or eye irritation (Bryant). Carrier says refrigerants can cause severe frostbite on contact with skin, and that breathing the fumes is hazardous to human health (Carrier). Carrier says EPA Section 608 rules bar deliberately releasing refrigerant during service, repair, or disposal (Carrier). Trane says only a licensed HVAC technician can do a recharge (Trane). Carrier says a DIY repair is illegal, dangerous, and likely to void the equipment warranty (Carrier).

Frequently asked

How long does AC refrigerant last?

Bryant says the refrigerant should last for the equipment's whole life, and it stays sealed (Bryant). Carrier says a home AC should never need a recharge under normal circumstances (Carrier).

If refrigerant is low, what does that mean?

Bryant says if levels are low, a leak is almost always the cause, and it has to be found and fixed (Bryant). Carrier says that if the system is low, a leak must be identified and sealed before new coolant is added (Carrier).

Can I just add more refrigerant?

No. Carrier calls simply adding more refrigerant a "temporary and often illegal band-aid" that can eventually lead to major compressor failure (Carrier). Bryant says refrigerant should only be added by a licensed HVAC technician (Bryant).

Is R-410A still available for repairs?

Bryant says R-410A is still available to service and repair existing systems (Bryant). Bryant also says new residential installs under the EPA's lower-GWP rules cannot use R-410A (Bryant).

Do I need to call a pro for this?

Yes. Refrigerant work needs a licensed contractor. Bryant says only a licensed HVAC technician should add refrigerant (Bryant). Bryant says direct contact may bring on frostbite or eye irritation (Bryant). For a homeowner check, Trane says keeping up with air filter changes can help head off a frozen evaporator coil (Trane).

Related

Questions about a specific system can go to Blume Mechanical Service at (727) 330-9131.

Sources: Trane, What Is a Home AC Recharge and Do I Need One?, https://www.trane.com/residential/en/resources/glossary/what-is-a-home-ac-recharge/ · Carrier, What is a Home AC Recharge?, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/home-ac-recharge/ · Carrier, How to Fix a Refrigerant Leak in Your AC Unit, https://www.carrier.com/us/en/residential/hvac-resources/air-conditioners/fix-a-refrigerant-leak/ · Bryant, What is AC Refrigerant?, https://www.bryant.com/en/us/products/air-conditioners/what-is-ac-refrigerant/

Search Google for does refrigerant go bad