HVAC, explained
ENERGY STAR commercial kitchen equipment and energy use
ENERGY STAR says certified commercial kitchen equipment helps cafe, restaurant, and institutional kitchens save energy (ENERGY STAR). ENERGY STAR says restaurants use about five to seven times more energy per square foot than other commercial buildings (ENERGY STAR). FEMP says idle or standby energy use is a significant portion of griddle energy use (FEMP).
A commercial kitchen runs many energy-using machines during long hours. This guide summarizes what federal sources say about where that energy goes and which equipment features they recommend. Each statement names its source, so you can check it against the original page. The findings are general and do not replace a site survey of your own kitchen.
Where restaurant energy goes
ENERGY STAR says restaurants use about five to seven times more energy per square foot than other commercial buildings (ENERGY STAR). The same source says restaurants generally use the most electricity for refrigeration, followed by lighting, then cooling (ENERGY STAR).
Refrigeration is the first item in that typical order (ENERGY STAR). Lighting and cooling come next in that typical order, so a review of all three gives a fuller picture than one piece of equipment alone.
Use these figures as a general guide. A walk-through of your own equipment list and operating hours will show which items matter most in your kitchen.
What ENERGY STAR certified equipment means
ENERGY STAR says certified commercial kitchen equipment helps cafe, restaurant, and institutional kitchens save energy (ENERGY STAR). The certification is a label to check on the product, not a promise about any one kitchen's bill.
ENERGY STAR advises asking your dealer or kitchen designer to supply ENERGY STAR certified equipment (ENERGY STAR). Put that request in writing before you order, so the quote and the delivered model can be compared.
Ask the dealer to name the exact model numbers that carry the label. Keep those numbers with the purchase records for future service.
Griddles: idle time and unused sections
FEMP says idle or standby energy use is a significant portion of griddle energy use (FEMP). Idle time is the period when the griddle is on but not cooking, so the appliance still uses energy.
For griddles with multiple sections, FEMP says to turn off unused sections during slow periods (FEMP). A shift leader can set this as a routine step at the start of each slow period.
FEMP also says double-sided griddles should have their tops down when not in use, which improves insulation and heat retention (FEMP). Double-sided griddles are one of the equipment types covered in FEMP's griddle guidance.
Ovens: preheat and door seals
FEMP says improved insulation and door gaskets let efficient ovens preheat more quickly than conventional models (FEMP). Faster preheat means the oven reaches cooking temperature with less time spent waiting at full power.
Door gaskets are a maintenance item as well as a purchase feature. Check the door gaskets during routine cleaning.
When you compare oven models, ask the dealer which insulation and gasket features the model includes, and ask for the rated preheat time in the product data.
Dishwashers and ice machines
FEMP says ensuring that commercial kitchen equipment uses water efficiently affords both significant water and energy savings (FEMP).
FEMP recommends purchasing high-efficiency commercial dishwashers that are ENERGY STAR-qualified (FEMP). For ice machines, FEMP's purchasing specification for air-cooled ice machines requires ENERGY STAR-qualified equipment (FEMP). That requirement applies to federal purchasing (FEMP).
Ask the installer whether the unit you choose is ENERGY STAR-qualified, and get that answer in writing.
Lighting and daily operations
ENERGY STAR recommends replacing old Open/Closed and EXIT signs with LED lighting (ENERGY STAR).
ENERGY STAR recommends turning off lights in unoccupied areas and where daylight is sufficient (ENERGY STAR). Assign one person to walk the back of house before close, so storage rooms and restrooms are not left lit.
ENERGY STAR also recommends a startup and shutdown plan, so only the equipment you need runs, when you need it (ENERGY STAR). Write the plan down, and post it near the equipment panel.
Air filters and HVAC upkeep
ENERGY STAR recommends checking the air filter every month, especially during heavy use months (ENERGY STAR). Heavy use months named by the source are winter and summer.
Note the date of each check in a log so the next check is not missed.
Ask your HVAC contractor which filter size your system uses.
Questions to ask before you buy
Ask the dealer to supply ENERGY STAR certified equipment (ENERGY STAR). Ask whether the product is ENERGY STAR-qualified, (FEMP). Compare the quotes on the same points: the label, the model number, the preheat or idle features, and the water use.
Blume Mechanical Service repairs, installs and maintains HVAC and refrigeration equipment, so a refrigeration or HVAC check can cover the cooling equipment that serves a commercial kitchen.
Frequently asked
What uses the most electricity in a restaurant?
ENERGY STAR says restaurants generally use the most electricity for refrigeration, followed by lighting, then cooling (ENERGY STAR). This describes typical restaurants, not every kitchen.
How much energy do restaurants use compared with other commercial buildings?
ENERGY STAR says restaurants use about five to seven times more energy per square foot than other commercial buildings (ENERGY STAR). The figure is per square foot.
Does idle time use griddle energy?
FEMP says idle or standby energy use is a significant portion of griddle energy use (FEMP). FEMP also says to turn off unused sections of multi-section griddles during slow periods (FEMP).
Do efficient ovens heat up faster?
FEMP says improved insulation and door gaskets let efficient ovens preheat more quickly than conventional models (FEMP). The source describes preheat time, not total energy use.
Should a kitchen buy ENERGY STAR dishwashers?
FEMP recommends purchasing high-efficiency commercial dishwashers that are ENERGY STAR-qualified (FEMP). The recommendation applies to commercial dishwashers.
What does the ENERGY STAR label tell a buyer?
ENERGY STAR says certified commercial kitchen equipment helps cafe, restaurant, and institutional kitchens save energy (ENERGY STAR). The statement is general, so ask the dealer for model numbers and check them against your own equipment.
Related
- Indoor air quality in schools and HVAC
- Commercial building ventilation and outdoor air basics
- Commercial refrigeration and food safety temperatures
Need an HVAC or refrigeration check for your commercial kitchen? Blume Mechanical Service (CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.
Sources: ENERGY STAR (U.S. EPA and DOE) — Commercial Food Service Equipment | ENERGY STAR (https://www.energystar.gov/products/commercial_food_service_equipment) · ENERGY STAR (U.S. EPA and DOE) — ENERGY STAR for Small Business: Restaurants (https://www.energystar.gov/buildings/resources-audience/small-biz/restaurants) · U.S. Department of Energy, Federal Energy Management Program (FEMP) — Purchasing Energy-Efficient Commercial Griddles (https://www.energy.gov/cmei/femp/purchasing-energy-efficient-commercial-griddles) · U.S. Department of Energy, Federal Energy Management Program (FEMP) — Purchasing Energy-Efficient Commercial Ovens (https://www.energy.gov/cmei/femp/purchasing-energy-efficient-commercial-ovens) · U.S. Department of Energy, Federal Energy Management Program (FEMP) — Best Management Practice #11: Commercial Kitchen Equipment (https://www.energy.gov/eere/femp/best-management-practice-11-commercial-kitchen-equipment)