Blume Mechanical ServiceBlumeMechanical Service

HVAC, explained

Attic knee wall insulation and air sealing

An attic knee wall is a vertical separation between attic space and conditioned space (FSEC). FSEC says insulation in a knee wall often sags or falls out, and that each of the six sides should be sealed (FSEC). The insulation level should be equivalent to the ceiling insulation (FSEC).

This page explains what the Florida Solar Energy Center (FSEC) says about attic knee walls. It covers why their insulation can fail, how air moves through them, and which sealing steps FSEC describes for new walls and for existing ones. Each fact names its source so you can check it against the original page.

What an attic knee wall is

An attic knee wall is a vertical separation between attic space on one side and conditioned space on the other side (FSEC).

FSEC says that, like all barriers between conditioned space and the attic, a knee wall can have pathways at any drywall penetration unless it is sealed (FSEC).

Those penetrations include openings for lights, outlets, ductwork and other features (FSEC).

FSEC says a knee wall is a vertical separation between attic space on one side and conditioned space on the other side (FSEC).

Why knee wall insulation sags

FSEC says a knee wall has no mandatory back, so insulation placed in the wall often sags or falls out (FSEC). FSEC says ceiling insulation requirements far exceed what fits in a 2x4 wall, which makes that insulation difficult to attach (FSEC).

FSEC says that insulation placed in a knee wall often sags or falls out, leaving an uninsulated wall (FSEC).

How air moves through a knee wall

FSEC says knee walls can suffer from insufficient air barriers (FSEC). FSEC says drywall may work as an air barrier if it is not penetrated (FSEC).

The bottom plate of a knee wall rests on the floor joists, which leaves a large pathway for attic air to rise into the wall cavity (FSEC).

FSEC says that without an air barrier on the back of the knee wall, attic air goes around the insulation into the cavity (FSEC). FSEC also says there is potential for air leakage from above the knee wall (FSEC).

FSEC says there is potential for air leakage from above the knee wall, as well as through the bottom plate pathway described above (FSEC).

Avoiding knee walls in new homes

In new construction, FSEC says to avoid knee walls as much as possible (FSEC). FSEC says exterior walls and flat ceilings are easier to insulate and seal (FSEC).

If a knee wall is built, FSEC says to keep ductwork and electrical runs outside the wall area before framing it (FSEC). FSEC says to construct the wall with sufficient room for the insulation you want (FSEC).

FSEC says that a knee wall built this way should not be more of an energy burden than equivalent areas of the attic ceiling (FSEC).

FSEC names exterior walls and flat ceilings as the easier surfaces to insulate and seal (FSEC).

Sealing all six sides

FSEC says to seal each of the six sides of each knee wall (FSEC). This means sealing off the floor joists and roof joists below and above the wall (FSEC).

FSEC also says to seal all penetrations into the wall from the drywall (FSEC).

FSEC says a knee wall may need a back built from any material accepted as fire-rated for attics (FSEC). FSEC lists taped and mudded drywall as one possibility (FSEC).

FSEC says an unsealed penetration in the drywall can leave a potential pathway for air (FSEC). FSEC says to seal each of the six sides of each knee wall (FSEC).

How deep the insulation should go

FSEC says the insulation level in a knee wall should be equivalent to the ceiling insulation (FSEC).

FSEC gives an example in which R-38 insulation may be 12 inches of batt insulation material (FSEC).

FSEC says to build the wall with appropriate studs to the desired depth (FSEC). FSEC also says to construct the wall with sufficient room for the insulation desired (FSEC).

Retrofitting an existing knee wall

For a retrofit, FSEC says to follow the new-build steps as much as possible (FSEC). FSEC says you may not have room to build a new knee wall, but foam air barriers may block airflow below and above the wall (FSEC).

If there is existing insulation, FSEC says to check it for sags or gaps (FSEC).

Have a qualified insulation or weatherization contractor do attic sealing and insulation work.

Frequently asked

What is an attic knee wall?

An attic knee wall is a vertical separation between attic space on one side and conditioned space on the other side (FSEC). It is one of the barriers between living space and the attic (FSEC). FSEC says all barriers between conditioned space and the attic can have pathways where drywall is penetrated (FSEC).

Why does knee wall insulation fall out?

FSEC says a knee wall has no mandatory back, so insulation in the wall often sags or falls out (FSEC). FSEC also says ceiling insulation is difficult to attach in a 2x4 wall (FSEC). FSEC says the insulation in a knee wall often sags or falls out, leaving an uninsulated wall (FSEC).

Should a new home have knee walls?

In new construction, FSEC says to avoid knee walls as much as possible (FSEC). FSEC says exterior walls and flat ceilings are easier to insulate and seal (FSEC).

Does a knee wall need sealing on every side?

FSEC says to seal each of the six sides of each knee wall (FSEC). Those sides include the floor joists and roof joists below and above the wall (FSEC).

How much insulation goes in a knee wall?

FSEC says the insulation level should be equivalent to the ceiling insulation (FSEC). FSEC gives an example in which R-38 insulation may be 12 inches of batt insulation material (FSEC).

Can an existing knee wall be sealed without rebuilding it?

FSEC says foam air barriers may block airflow below and above the knee wall when there is no room to build a new one (FSEC). FSEC also says to check existing insulation for sags or gaps (FSEC).

Related

Need an HVAC check on the air conditioner in your Florida home? Blume Mechanical Service (CAC-1822618) repairs, installs and maintains HVAC and refrigeration equipment in Pinellas, Hillsborough and Pasco counties. Call 727-330-9131.

Sources: Florida Solar Energy Center (FSEC) — Attic Knee Wall (https://energyresearch.ucf.edu/research/buildings-research/roof-assembly/attic-knee-wall/) · Florida Solar Energy Center (FSEC) — Attic Insulation and Ventilation (https://energyresearch.ucf.edu/research/buildings-research/roof-assembly/attic-insulation-ventilation/)

Search Google for attic knee wall insulation